Polyaniline based catalase biosensor for the detection of hydrogen peroxide and azide

被引:0
|
作者
Ravindra P. Singh
Da-Yeon Kang
Byung-Keun Oh
Jeong-Woo Choi
机构
[1] Sogang University,Department of Chemical and Biomolecular Engineering
[2] Sogang University,Interdisciplinary Program of Integrated Biotechnology
关键词
Polyaniline (PANi); catalase (CAT); hydrogen peroxide (H; O; ); azide; biosensor; bioelectrode;
D O I
暂无
中图分类号
学科分类号
摘要
The CAT/PANi/ITO bioelectrode has been prepared as a catalase biosensor and shows response for monitoring not only of H2O2 but also azide. The sensor exhibited an excellent response to the H2O2 and azide. The linear range of H2O2 was 0.064∼1 mM and for azide 0.125∼4 mM, respectively. Catalase biosensor was based on the principle of the measurements as the decrease in the differentiation of oxygen level, which has been caused by the inhibition of catalase in the bioactive layer of the biosensor by azide. The repeatability experiments were done in triplicate. The logarithm response of the biosensor to H2O2 (r2 = 0.99), as well as, for azide (r2 = 0.90) were reported, respectively. The bioelectrode was characterized by CV and AFM. The proposed biosensor would be applied for the determination of H2O2 and azide in various biological samples.
引用
收藏
页码:443 / 449
页数:6
相关论文
共 50 条
  • [41] Decomposition of hydrogen peroxide by catalase
    Johnson, FH
    van Schouwenburg, KL
    NATURE, 1939, 144 : 634 - 635
  • [42] Cyanobacterial Phycocyanin-Based Electrochemical Biosensor for the Detection of the Free Radical Hydrogen Peroxide
    Sivasankari, Sivaprakasam
    Vinoth, Mani
    Ravindran, Abraham David
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2024, : 8907 - 8924
  • [43] A novel electrochemiluminescent biosensor based on cationic polymer/chitosan for ultrasensitive detection of hydrogen peroxide
    Wang, Y.
    Dai, H.
    Wu, X.
    Chen, G.
    LUMINESCENCE, 2008, 23 (02) : 98 - 98
  • [44] Influence of calcium on glucose biosensor response and on hydrogen peroxide detection
    Labat-Allietta, N
    Thevenot, DR
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (01): : 19 - 29
  • [45] Influence of calcium on glucose biosensor response and on hydrogen peroxide detection
    Labat-Allietta, Nathalie
    Thévenot, Daniel R.
    Biosensors and Bioelectronics, 1998, 13 (01): : 19 - 29
  • [46] REACTIONS OF CATALASE WITH HYDROGEN PEROXIDE AND HYDROGEN DONORS
    KEILIN, D
    NICHOLLS, P
    BIOCHIMICA ET BIOPHYSICA ACTA, 1958, 29 (02) : 302 - 307
  • [47] RAPID PROCEDURE FOR DETECTION OF HYDROGEN PEROXIDE-CATALASE TREATED MILK
    BARONE, WB
    KRETT, OJ
    JOURNAL OF DAIRY SCIENCE, 1969, 52 (06) : 882 - &
  • [48] Bacteria-based biosensor for determination of hydrogen peroxide
    Tai, GY
    Wen, ML
    Wang, CY
    MICROCHEMICAL JOURNAL, 1996, 53 (02) : 152 - 157
  • [49] A hydrogen peroxide amperometric biosensor based on carbon nanotubes
    Mai Zhibin
    Tan Xuecai
    Zou Xiaoyong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (06) : 801 - 804
  • [50] OXIDATION OF AZIDE IONS BY HYDROGEN PEROXIDE
    HOFMANBANG, N
    ACTA CHEMICA SCANDINAVICA, 1964, 18 (05): : 1300 - &