The transmission Compton polarimeter of the A4 experiment

被引:0
|
作者
Christoph Weinrich
机构
[1] Johannes-Gutenberg-Universtität,
[2] Institut für Kernphysik,undefined
[3] J.-J.-Becher-Weg 45,undefined
[4] 55099 Mainz,undefined
来源
关键词
Permanent Magnet; Secondary Electron; Electron Emission; Parity Violation; Beam Polarisation;
D O I
10.1140/epjad/s2005-04-030-2
中图分类号
学科分类号
摘要
A transmission Compton polarimeter as a simultaneous, relative monitor for the longitudinal polarisation of a stabilised, polarised electron beam (polarisation degree ~ 80 %) has been constructed in a new design. It is located in the vacuum between the target and the beam dump of the A4 parity violation experiment at MAMI. The analysing power is ~ 80 ppm at 854 MeV and ~ 115 ppm at 570 MeV. The measurement precision for the polarimeter asymmetry (which is proportional to the longitudinal beam polarisation degree) is ~ 3 ppm within 5 min. at 854 MeV and ~ 7 ppm within 5 min. at 570 MeV and the systematical error is about 0.5 ppm + 1 - 2 %. This simple polarimeter consists mainly of two graphite scatterers, a water-cooled Samarium-Cobalt permanent magnet, an aluminum secondary electron emission monitor, an understructure and electronics.
引用
收藏
页码:129 / 130
页数:1
相关论文
共 50 条
  • [31] Electron beam polarization with the Compton polarimeter at JLab
    Pussieux, T
    SPIN 2000, 2001, 570 : 761 - 764
  • [32] ON RELATIVE MERITS OF A NAI(TL) COMPTON POLARIMETER
    TARAS, P
    MATAS, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (12): : 1229 - &
  • [33] A COMPTON POLARIMETER COMPOSED OF 4-PLANAR DIODES OF HIGH-PURITY GERMANIUM
    ISHII, M
    OHSHIMA, M
    MATSUZAKI, T
    TAKETANI, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (01): : 117 - 119
  • [34] Transverse spin asymmetry at the A4 experiment - Experimental results
    Baunack, S
    EUROPEAN PHYSICAL JOURNAL A, 2005, 24 (Suppl 2): : 35 - 38
  • [35] Single spin asymmetries from the Mainz A4 experiment
    Baunack, S
    NUCLEAR PHYSICS A, 2005, 755 : 249C - 252C
  • [36] The parity violation A4 experiment at forward and backward angles
    S. Baunack
    The European Physical Journal A, 2007, 32 : 457 - 461
  • [37] A luminosity monitor for the A4 parity violation experiment at MAMI
    Hammel, T.
    Achenbach, P.
    Baunack, S.
    Capozza, L.
    Diefenbach, J.
    Grimm, K.
    von Harrach, D.
    Imai, Y.
    Kabuss, E.
    Kothe, R.
    Lee, J. H.
    Lopes Ginja, A.
    Maas, F. E.
    Sanchez Lorente, A.
    Schilling, E.
    Stephan, G.
    Weinrich, C.
    Altarev, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 564 (01): : 1 - 12
  • [38] The parity violation A4 experiment at forward and backward angles
    Baunack, S.
    EUROPEAN PHYSICAL JOURNAL A, 2007, 32 (04): : 456 - 461
  • [39] HIGH-RESOLUTION, HIGH SENSITIVITY COMPTON POLARIMETER
    CANTY, MJ
    NESKAKIS, A
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (01): : 1 - 7
  • [40] APPLICATION OF A SECTORED GE(LI) DETECTOR AS A COMPTON POLARIMETER
    SIMPSON, J
    BUTLER, PA
    EKSTROM, LP