The transmission Compton polarimeter of the A4 experiment

被引:0
|
作者
Christoph Weinrich
机构
[1] Johannes-Gutenberg-Universtität,
[2] Institut für Kernphysik,undefined
[3] J.-J.-Becher-Weg 45,undefined
[4] 55099 Mainz,undefined
来源
关键词
Permanent Magnet; Secondary Electron; Electron Emission; Parity Violation; Beam Polarisation;
D O I
10.1140/epjad/s2005-04-030-2
中图分类号
学科分类号
摘要
A transmission Compton polarimeter as a simultaneous, relative monitor for the longitudinal polarisation of a stabilised, polarised electron beam (polarisation degree ~ 80 %) has been constructed in a new design. It is located in the vacuum between the target and the beam dump of the A4 parity violation experiment at MAMI. The analysing power is ~ 80 ppm at 854 MeV and ~ 115 ppm at 570 MeV. The measurement precision for the polarimeter asymmetry (which is proportional to the longitudinal beam polarisation degree) is ~ 3 ppm within 5 min. at 854 MeV and ~ 7 ppm within 5 min. at 570 MeV and the systematical error is about 0.5 ppm + 1 - 2 %. This simple polarimeter consists mainly of two graphite scatterers, a water-cooled Samarium-Cobalt permanent magnet, an aluminum secondary electron emission monitor, an understructure and electronics.
引用
收藏
页码:129 / 130
页数:1
相关论文
共 50 条
  • [21] PERSPECTIVES OF EXPERIMENTS WITH COMPTON POLARIMETER IN ASTROPHYSICS
    GORODINSKII, GM
    ERMOLAEV, BI
    ZAITSEV, SV
    KRUGLOV, EM
    KHMYLKO, VV
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1984, 48 (11): : 2090 - 2092
  • [22] Measuring the Neutrino Helicity with a Compton Polarimeter
    V. B. Brudanin
    V. G. Egorov
    I. V. Zhitnikov
    M. V. Shirchenko
    Yu. A. Shitov
    Physics of Particles and Nuclei Letters, 2019, 16 : 537 - 541
  • [23] Polarization reconstruction algorithm for a Compton polarimeter
    Vockert, M.
    Weber, G.
    Spillmann, U.
    Krings, T.
    Stoehlker, Th
    FAIRNESS 2017: FAIR NEXT GENERATION SCIENTISTS 2017, 2018, 1024
  • [24] The MIT-Bates Compton Polarimeter
    Franklin, WA
    Akdogan, T
    Dutta, D
    Farkhondeh, M
    Hurwitz, M
    Matthews, JL
    Tsentalovich, E
    Turchinetz, W
    Zwart, T
    Booth, E
    SPIN 2002, 2003, 675 : 1058 - 1062
  • [25] Measuring the Neutrino Helicity with a Compton Polarimeter
    Brudanin, V. B.
    Egorov, V. G.
    Zhitnikov, I. V.
    Shirchenko, M. V.
    Shitov, Yu. A.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2019, 16 (05) : 537 - 541
  • [26] DEVELOPMENT OF A COMPTON POLARIMETER WITH SOLID STATE DETECTORS
    HARDY, KA
    LUMPKIN, A
    LEE, YK
    OWEN, GE
    SHNIDMAN, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (04): : 482 - &
  • [27] ASYMMETRY RATIO OF A COMPTON POLARIMETER - A COMPUTER PROGRAM
    TARAS, P
    MATAS, J
    NUCLEAR INSTRUMENTS & METHODS, 1968, 61 (03): : 317 - &
  • [28] A combined high energy Moeller and Compton polarimeter
    Avakian, RH
    Avetisyan, AE
    Bosted, P
    Dallakian, KR
    Darbinian, SM
    Ispirian, KA
    Kerobyan, IA
    ADVANCED RADIATION SOURCES AND APPLICATIONS, 2006, 199 : 351 - +
  • [29] A COMPTON POLARIMETER FOR 2-MEV BREMSSTRAHLUNG
    RANK, D
    UNFRIED, E
    ZEITSCHRIFT FUR PHYSIK, 1970, 233 (03): : 231 - &
  • [30] A Compton polarimeter for Parametric X-radiation
    They, J
    Buschhorn, G
    Kotthaus, R
    Pugachev, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1167 - 1170