Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup

被引:0
|
作者
E. García-Rey
E. García-Cimbrelo
机构
[1] Hospital La Paz,Department of Orthopaedics
来源
关键词
Femoral Head; Acetabular Component; Polyethylene Wear; Polyethylene Liner; Metal Shell;
D O I
暂无
中图分类号
学科分类号
摘要
We compared clinical results and wear performance in two different generations of a cementless porous-coated cup, analysing the long-term results of 83 uncemented Harris-Galante I cups (32-mm femoral head) and 93 uncemented Harris-Galante II cups (28-mm femoral head). All polyethylene liners were gamma irradiated in air. Polyethylene linear wear was estimated using a software package. The minimum follow-up was 10 years. Nine Harris-Galante I cups and two Harris-Galante II cups were revised due to aseptic loosening or polyethylene problems. The mean femoral head penetration at 6 weeks after surgery was 0.15 ± 0.05 mm for the Harris-Galante I cups and 0.12 ± 0.03 for the Harris-Galante II cups (p < 0.001);but mean wear was 0.13 ± 0.23 mm per year for the Harris-Galante I cups and 0.11 ± 0.10 for the Harris-Galante II cups (p = 0.740). Most of the metallic shells in both groups showed stable fixation. The so-called second-generation cups had lower initial polyethylene wear that resulted in less polyethylene wear at the latest the follow-up, but the overall wear rate was similar in both groups despite the different femoral head sizes and the improved locking mechanism.
引用
收藏
页码:181 / 187
页数:6
相关论文
共 50 条
  • [1] Clinical and radiographic results and wear performance in different generations of a cementless porous-coated acetabular cup
    Garcia-Rey, E.
    Garcia-Cimbrelo, E.
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (02) : 181 - 187
  • [2] Bedding-in and true wear in two different generations cementless porous-coated acetabular cups
    Garcia-Rey, Eduardo
    HIP INTERNATIONAL, 2010, 20 : S86 - S93
  • [3] THE CLINICAL AND ROENTGENOGRAPHIC RESULTS OF CEMENTLESS POROUS-COATED PATELLAR FIXATION
    FIRESTONE, TP
    TEENY, SM
    KRACKOW, KA
    HUNGERFORD, DS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (273) : 184 - 189
  • [4] Radiographic signs of osseointegration in porous-coated acetabular components
    Moore, Milan S.
    McAuley, James P.
    Young, Anthony M.
    Engh, Charles A., Sr.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) : 176 - 183
  • [5] Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup
    Orishimo, KF
    Claus, AM
    Sychterz, CJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (05): : 1099 - 1099
  • [6] FIXATION OF CEMENTLESS ACETABULAR CUPS - A RADIOGRAPHIC 4-8-YEAR STUDY OF 102 POROUS-COATED COMPONENTS
    CORDEROAMPUERO, J
    GARCIACIMBRELO, E
    MUNUERA, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (03): : 263 - 266
  • [7] Porous-Coated Cementless Acetabular Components Without Bulk Bone Graft in Revision Surgery
    Ito, Hiroshi
    Tanino, Hiromasa
    Yamanaka, Yasuhiro
    Sato, Tatsuya
    Minami, Akio
    Matsuno, Takeo
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08): : 1307 - 1310
  • [8] HISTOLOGY OF POROUS-COATED ACETABULAR COMPONENTS - 25 CEMENTLESS CUPS RETRIEVED AFTER ARTHROPLASTY
    SUMNER, DR
    JASTY, M
    JACOBS, JJ
    URBAN, RM
    BRAGDON, CR
    HARRIS, WH
    GALANTE, JO
    ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (06): : 619 - 626
  • [9] KNEE ARTHROPLASTY USING A CEMENTLESS PCA PROSTHESIS WITH A POROUS-COATED CENTRAL TIBIAL STEM - CLINICAL AND RADIOGRAPHIC REVIEW AT 5 YEARS
    KIM, YH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (03): : 412 - 417
  • [10] Early Catastrophic Failure of a Porous-Coated Acetabular Cup due to Bead Shedding. A Case Report
    Hsu, Andrew R.
    Vaughn, Zackary
    Huddleston, James I.
    HIP INTERNATIONAL, 2009, 19 (04) : 392 - 395