Role of proficiency testing in monitoring of standardization of hemoglobin A1c methods

被引:0
|
作者
Berna Aslan
Jane Gun-Munro
Gregory J. Flynn
机构
[1] Institute for Quality Management in Healthcare (IQMH),Ontario Medical Association
[2] Quality Management Program—Laboratory Services (QMP–LS),Ontario Medical Association
来源
关键词
HbA; Method standardization; External quality assessment; Proficiency testing;
D O I
暂无
中图分类号
学科分类号
摘要
After Hemoglobin A1c (HbA1c), therapeutic targets for monitoring diabetes therapy were recommended, first, National Glycohemoglobin Standardization Program (NGSP), then, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) developed standardization initiatives. The aim of this article is to demonstrate the role of a proficiency testing (PT) programs in monitoring the long-term effect of these initiatives and the current status of HbA1c measurement. Measurement precision as a coefficient of variation (CV), measurement bias (bias), and satisfactory HbA1c result rates in proficiency testing (PT) surveys were evaluated using fresh single donor whole blood PT items and assigned values from a NGSP-certified secondary reference laboratory. Between 2000 and 2010, both CV and bias of the IC measurement method showed a decreasing trend. While the CV of the HPLC measurement method decreased, no significant change was observed in its bias. The rates of satisfactory HbA1c results in PT surveys were higher in HPLC users than IC users. In 2010, the average CVs in HPLC and IC groups were 2.6 and 3.4 %, biases were 2.7 and 1.8 %, and corresponding total error (TE) estimates were 7.8 and 8.5 %, respectively. These TE values were higher than the maximum permissible measurement error of 7 %, developed based on clinical use of the test. The NGSP and the IFCC networks have promoted improvements in HbA1c testing; however, tightening of NGSP method certification criteria seems to be necessary to achieve a maximum permissible measurement error of 7 %.
引用
收藏
页码:419 / 424
页数:5
相关论文
共 50 条
  • [41] Point-of-care hemoglobin A1c testing in postmortem examination
    Joo-Young Na
    Forensic Science, Medicine and Pathology, 2018, 14 : 322 - 326
  • [42] A new hemoglobin A1c testing system improves patient compliance
    Shea, RS
    Pfaltzgraff, LR
    Sangha, J
    Chaturvedi, S
    Ali, SM
    DIABETES, 1999, 48 : A349 - A349
  • [43] Hemoglobin A1c testing is associated with improved pancreas utilization for transplant
    Torres-Quinones, Maritza
    Stern, Jeffrey
    Seals, Nicholas
    Giglio, Gysel
    Meza, Kathryn
    Carpini, Kristin Delli
    Icitovic, Nikolina
    Tajik, Waheed
    O'Hara, David
    Lerner, Harvey
    Goldstein, Michael J.
    PROGRESS IN TRANSPLANTATION, 2013, 23 (01) : 84 - 91
  • [45] Effect of Self-Monitoring Clusters on Weight and Hemoglobin A1c
    Padhye, Nikhil S.
    Wang, Jing
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 275 - 278
  • [46] Effects of hemoglobin C, D, E and S traits on measurements of hemoglobin A1c by twelve methods
    Rohlfing, Curt
    Hanson, Steven
    Weykamp, Cas
    Siebelder, Carla
    Higgins, Trefor
    Molinaro, Ross
    Yip, Paul M.
    Little, Randie R.
    CLINICA CHIMICA ACTA, 2016, 455 : 80 - 83
  • [47] MORTALITY, GLYCEMIC CONTROL AND HEMOGLOBIN A1C (A1C) IN THE ICU
    Carpenter, David
    Gregg, Sara
    Xu, Kejun
    Coopersmith, Craig
    CRITICAL CARE MEDICINE, 2015, 43 (12)
  • [48] COMPARISON OF TWO IMMUNOTURBIDIMETRIC METHODS FOR THE MEASUREMENT OF GLYCATED HEMOGLOBIN A1C
    Pagliano, F.
    Misino, S.
    Almagro, M. E.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S365 - S365
  • [49] Analytic bias among certified methods for the measurement of hemoglobin A1c
    Holmes, Earle W.
    Ersahin, Cagatay
    Augustine, Geri J.
    Charnogursky, Gerald. A.
    Gryzbac, Margie
    Murrell, Joanne V.
    McKenna, Kathleen M.
    Nabhan, Fadi
    Kahn, Stephen E.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 129 (04) : 540 - 547
  • [50] Analytical performance evaluation of three methods for hemoglobin A1c quantification
    Unger, Gisela
    Ruiz, Gustavo
    Milano, Pablo
    Fabiana Benozzi, Silvia
    Laura Pennacchiotti, Graciela
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2014, 48 (02): : 183 - 189