Role of proficiency testing in monitoring of standardization of hemoglobin A1c methods

被引:0
|
作者
Berna Aslan
Jane Gun-Munro
Gregory J. Flynn
机构
[1] Institute for Quality Management in Healthcare (IQMH),Ontario Medical Association
[2] Quality Management Program—Laboratory Services (QMP–LS),Ontario Medical Association
来源
关键词
HbA; Method standardization; External quality assessment; Proficiency testing;
D O I
暂无
中图分类号
学科分类号
摘要
After Hemoglobin A1c (HbA1c), therapeutic targets for monitoring diabetes therapy were recommended, first, National Glycohemoglobin Standardization Program (NGSP), then, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) developed standardization initiatives. The aim of this article is to demonstrate the role of a proficiency testing (PT) programs in monitoring the long-term effect of these initiatives and the current status of HbA1c measurement. Measurement precision as a coefficient of variation (CV), measurement bias (bias), and satisfactory HbA1c result rates in proficiency testing (PT) surveys were evaluated using fresh single donor whole blood PT items and assigned values from a NGSP-certified secondary reference laboratory. Between 2000 and 2010, both CV and bias of the IC measurement method showed a decreasing trend. While the CV of the HPLC measurement method decreased, no significant change was observed in its bias. The rates of satisfactory HbA1c results in PT surveys were higher in HPLC users than IC users. In 2010, the average CVs in HPLC and IC groups were 2.6 and 3.4 %, biases were 2.7 and 1.8 %, and corresponding total error (TE) estimates were 7.8 and 8.5 %, respectively. These TE values were higher than the maximum permissible measurement error of 7 %, developed based on clinical use of the test. The NGSP and the IFCC networks have promoted improvements in HbA1c testing; however, tightening of NGSP method certification criteria seems to be necessary to achieve a maximum permissible measurement error of 7 %.
引用
收藏
页码:419 / 424
页数:5
相关论文
共 50 条
  • [21] 2010 Consensus Statement on the Worldwide Standardization of the Hemoglobin A1c Measurement
    Hanas, Ragnar
    John, Garry
    CLINICAL CHEMISTRY, 2010, 56 (08) : 1362 - 1364
  • [22] 2010 Consensus statement on the worldwide standardization of the hemoglobin A1c measurement
    Hanas, Ragnar
    John, Garry
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2010, 90 (02) : 228 - 230
  • [23] Recommendations for proficiency testing criteria for hemoglobin A1c based on the Shanghai Center for Clinical Laboratory's study
    Ju, Yi
    Cao, Zhimin Tim
    Li, Qing
    Tang, Liping
    Ou, Yuanzhu
    Yu, Xiaoxuan
    Liu, Wenbin
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (10) : 1728 - 1734
  • [24] STANDARDIZATION AND METHODS FOR PROFICIENCY TESTING IN HISTOPATHOLOGY AND CYTOLOGY
    BARGER, JD
    PATHOLOGY, 1975, 7 (01) : 50 - 50
  • [25] Comparison of costs of hemoglobin A1c determination by point-of-care testing (POCT) and standard hemoglobin A1c analyzer
    Wiwanitkit, V.
    ARCHIVES OF HELLENIC MEDICINE, 2010, 27 (06): : 953 - 955
  • [26] TRENDS IN INTERLABORATORY STANDARDIZATION AND THE ROLE OF PROFICIENCY TESTING
    VANDERLINDE, RE
    LAESSIG, RH
    SIDEMAN, L
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1290 - 1290
  • [27] Alternate Site Testing for Hemoglobin A1C in Children With Diabetes
    Flores, Sarah L.
    DIABETES EDUCATOR, 2010, 36 (04): : 623 - 628
  • [28] Hemoglobin A1c Measurement Using Point of Care Testing
    Erdal, Gulcin Sahingoz
    Isiksacan, Nilgun
    Koser, Murat
    Kocamaz, Nursel
    ISTANBUL MEDICAL JOURNAL, 2020, 21 (01): : 37 - 41
  • [29] Frequency of Monitoring Hemoglobin A1C and Achieving Diabetes Control
    Parcero, Augusto F.
    Yaeger, Thomas
    Bienkowski, Robert S.
    JOURNAL OF PRIMARY CARE AND COMMUNITY HEALTH, 2011, 2 (03): : 205 - 208
  • [30] QUALITY SPECIFICATIONS FOR HEMOGLOBIN A1C ASSAYS IN THE MONITORING OF DIABETES
    LARSEN, ML
    PETERSEN, PH
    FRASER, CG
    UPSALA JOURNAL OF MEDICAL SCIENCES, 1993, 98 (03) : 335 - 338