The NIST high-flux backscattering spectrometer

被引:0
|
作者
R.M. Dimeo
Z. Chowdhuri
A. Meyer
P.M. Gehring
D.A. Neumann
机构
[1] National Institute of Standards and Technology,
[2] NIST Center for Neutron Research,undefined
[3] Gaithersburg,undefined
[4] MD 20899,undefined
[5] USA,undefined
[6] University of Maryland,undefined
[7] Department of Materials and Nuclear Engineering,undefined
[8] College Park,undefined
[9] MD 20742,undefined
[10] USA,undefined
[11] Technische Universität München,undefined
[12] Physik-Department E13,undefined
[13] 85747 Garching,undefined
[14] Germany,undefined
来源
Applied Physics A | 2002年 / 74卷
关键词
PACS: 61.12.Ex; 61.12.-g;
D O I
暂无
中图分类号
学科分类号
摘要
The neutron-backscattering technique extends the dynamic range of neutron time-of-flight and conventional triple-axis spectrometers down to μeV energies and is ideal for the study of slow motions in complex liquids, jump diffusion, and quantum rotational tunneling. We report on the performance of the new high-flux backscattering spectrometer (HFBS) at the NIST Center for Neutron Research. Compared to other backscattering spectrometers, the HFBS achieves a higher neutron intensity through the use of a device called a phase space transformation chopper and a large analyzer array. A custom-designed Doppler drive for the monochromator provides a triangular velocity profile capable of high-frequency operation, thus extending the dynamic range of the spectrometer by more than a factor of two over similar instruments.
引用
收藏
页码:s311 / s313
相关论文
共 50 条
  • [41] IMPORTANCE OF ENDOTOXINS IN HIGH-FLUX DIALYSIS
    SMOLLICH, BP
    FALKENHAGEN, D
    SCHNEIDEWIND, J
    MITZNER, S
    KLINKMANN, H
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 : 83 - 85
  • [42] High-Flux Irradiation of Open Samples
    J. Casta
    R. Gwozdz
    P. Katrik
    F. Grass
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 349 - 354
  • [43] High-flux magnetorheology at elevated temperatures
    Ocalan, Murat
    McKinley, Gareth H.
    RHEOLOGICA ACTA, 2013, 52 (07) : 623 - 641
  • [44] HIGH-FLUX GRAPHITE RESISTANCE HEATERS
    BABBE, E
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 145 - &
  • [45] VANCOMYCIN PHARMACOKINETICS IN HIGH-FLUX HEMODIALYSIS
    BARTH, RH
    DEVINCENZO, N
    ZARA, AC
    BERLYNE, GM
    CLINICAL RESEARCH, 1990, 38 (02): : A339 - A339
  • [46] HIGH-FLUX (HF) HEMODIALYSIS (HD)
    ACCHIARDO, S
    BURK, L
    BANNISTER, D
    KIDNEY INTERNATIONAL, 1987, 31 (01) : 226 - 226
  • [47] RAY TRACING OF A HIGH-FLUX BEAMLINE
    BAHRDT, J
    SCHWENTNER, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (1-2): : 237 - 239
  • [48] OPTIMUM SHUTDOWN OF A HIGH-FLUX REACTOR
    ZARITSKA.TS
    RUDIK, AP
    SOVIET ATOMIC ENERGY-USSR, 1971, 30 (04): : 467 - &
  • [49] High-flux irradiation of open samples
    Casta, J
    Gwozdz, R
    Katrik, P
    Grass, F
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 244 (02) : 349 - 354
  • [50] NEUTRON DIFFRACTION AT A HIGH-FLUX REACTOR
    BACON, GE
    DYER, RF
    NATURE, 1959, 183 (4653) : 35 - 35