The NIST high-flux backscattering spectrometer

被引:0
|
作者
R.M. Dimeo
Z. Chowdhuri
A. Meyer
P.M. Gehring
D.A. Neumann
机构
[1] National Institute of Standards and Technology,
[2] NIST Center for Neutron Research,undefined
[3] Gaithersburg,undefined
[4] MD 20899,undefined
[5] USA,undefined
[6] University of Maryland,undefined
[7] Department of Materials and Nuclear Engineering,undefined
[8] College Park,undefined
[9] MD 20742,undefined
[10] USA,undefined
[11] Technische Universität München,undefined
[12] Physik-Department E13,undefined
[13] 85747 Garching,undefined
[14] Germany,undefined
来源
Applied Physics A | 2002年 / 74卷
关键词
PACS: 61.12.Ex; 61.12.-g;
D O I
暂无
中图分类号
学科分类号
摘要
The neutron-backscattering technique extends the dynamic range of neutron time-of-flight and conventional triple-axis spectrometers down to μeV energies and is ideal for the study of slow motions in complex liquids, jump diffusion, and quantum rotational tunneling. We report on the performance of the new high-flux backscattering spectrometer (HFBS) at the NIST Center for Neutron Research. Compared to other backscattering spectrometers, the HFBS achieves a higher neutron intensity through the use of a device called a phase space transformation chopper and a large analyzer array. A custom-designed Doppler drive for the monochromator provides a triangular velocity profile capable of high-frequency operation, thus extending the dynamic range of the spectrometer by more than a factor of two over similar instruments.
引用
收藏
页码:s311 / s313
相关论文
共 50 条
  • [21] Warning of high-flux hemodialysis
    Takenaka, T
    Kobayashi, K
    Suzuki, H
    RENAL FAILURE, 2001, 23 (06) : 819 - 825
  • [22] THE HIGH-FLUX BEAMLINE AT THE ESRF
    BOSECKE, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 438 - 441
  • [23] HIGH-FLUX BREMSSTRAHLUNG SOURCE
    LABRIE, JP
    FUNK, LW
    GOWANS, S
    MCKEOWN, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03): : 359 - 363
  • [24] High-flux MFI membranes
    Hedlund, J
    Sterte, J
    Anthonis, M
    Bons, AJ
    Carstensen, B
    Corcoran, N
    Cox, D
    Deckman, H
    De Gijnst, W
    de Moor, PP
    Lai, F
    McHenry, J
    Mortier, W
    Reinoso, J
    MICROPOROUS AND MESOPOROUS MATERIALS, 2002, 52 (03) : 179 - 189
  • [25] Double high-flux Hemodiafiltration
    Von Albertini, Beat
    HEMODIAFILTRATION, 2007, 158 : 161 - 168
  • [26] β-trace protein is highly removed during haemodialysis with high-flux and super high-flux membranes
    Donadio, Carlo
    Tognotti, Danika
    Caponi, Laura
    Paolicchi, Aldo
    BMC NEPHROLOGY, 2017, 18
  • [27] β-trace protein is highly removed during haemodialysis with high-flux and super high-flux membranes
    Carlo Donadio
    Danika Tognotti
    Laura Caponi
    Aldo Paolicchi
    BMC Nephrology, 18
  • [28] IN20 – The ILL high-flux polarised-neutron three-axis spectrometer
    J. Kulda
    J. Šaroun
    P. Courtois
    M. Enderle
    M. Thomas
    P. Flores
    Applied Physics A, 2002, 74 : s246 - s248
  • [29] IN20 - The ILL high-flux polarised-neutron three-axis spectrometer
    Kulda, J
    Saroun, J
    Courtois, P
    Enderle, M
    Thomas, M
    Flores, P
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1): : S246 - S248
  • [30] All high-flux membranes are equal but some high-flux membranes are less equal than others
    Vanholder, Raymond
    Pedrini, Luciano A.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (05) : 1481 - 1483