Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique

被引:0
|
作者
Fortunato Iacovelli
Giuseppe Giugliano
Donato Gerardi
Luigi Salemme
Angelo Cioppa
Armando Pucciarelli
Grigore Popusoi
Francesco Loizzi
Giancarlo Schettino
Stefano Favale
Francesco Solimene
Giovanni Esposito
Tullio Tesorio
Eugenio Stabile
机构
[1] Policlinico University Hospital,Division of University Cardiology, Cardiothoracic Department
[2] University of Naples “Federico II”,Division of Cardiology, Department of Advanced Biomedical Sciences
[3] “San Giovanni di Dio” Hospital,Division of Cardiology
[4] “Montevergine” Clinic,Interventional Cardiology Service
[5] Vivasure Medical Ltd,Electrophysiology Service
[6] “Montevergine” Clinic,Division of Cardiology, Cardiovascular Department
[7] “San Carlo” Regional Hospital,undefined
来源
Heart and Vessels | 2022年 / 37卷
关键词
Transcatheter aortic valve implantation; Permanent pacemaker implantation predictors; Electrophysiological study; Calcium volume;
D O I
暂无
中图分类号
学科分类号
摘要
Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation (p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification (p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.
引用
收藏
页码:337 / 346
页数:9
相关论文
共 50 条
  • [41] Balloon-expandable Myval transcatheter aortic valve implantation. First experience in Spain
    Santos-Martinez, Sandra
    Amat-Santos, Ignacio J.
    Serrador, Ana
    Rodriguez-Gabella, Tania
    Gutierrez, Hipolito
    San Roman, Alberto
    REVISTA ESPANOLA DE CARDIOLOGIA, 2020, 73 (07): : 596 - 597
  • [42] Predictive Factors, Efficacy, and Safety of Balloon Post-Dilation After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
    Nombela-Franco, Luis
    Rodes-Cabau, Josep
    DeLarochelliere, Robert
    Larose, Eric
    Doyle, Daniel
    Villeneuve, Jacques
    Bergeron, Sebastien
    Bernier, Mathieu
    Amat-Santos, Ignacio J.
    Mok, Michael
    Urena, Marina
    Rheault, Michel
    Dumesnil, Jean
    Cote, Melanie
    Pibarot, Philippe
    Dumont, Eric
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 499 - 512
  • [43] Outcomes After Transcatheter Aortic Valve Implantation Using a Novel Balloon-Expandable Transcatheter Heart Valve: A Single Center Experience
    Husser, Oliver
    Pellegrini, Costanza
    Kessler, Thorsten
    Burgdorf, Christof
    Thaller, Hannah
    Mayr, Patrick
    Ott, Ilka
    Kasel, Markus
    Schunkert, Heribert
    Kastrati, Adnan
    Hengstenberg, Christian
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B55 - B56
  • [44] Feasibility and safety of early discharge after transfemoral transcatheter valve implantation with balloon-expandable prosthesis: a prospective study
    Cellier, G.
    Durand, E.
    El Hatimi, S.
    Tron, C.
    Cribier, A.
    Eltchaninoff, H.
    EUROPEAN HEART JOURNAL, 2015, 36 : 958 - 958
  • [45] Use of Balloon Aortic Valvuloplasty to Size the Aortic Annulus Before Implantation of a Balloon-Expandable Transcatheter Heart Valve
    Babaliaros, Vasilis C.
    Junagadhwalla, Zahid
    Lerakis, Stamatios
    Thourani, Vinod
    Liff, David
    Chen, Edward
    Vassiliades, Thomas
    Chappell, Clay
    Gross, Nathan
    Patel, Ateet
    Howell, Sharon
    Green, Jacob T.
    Veledar, Emir
    Guyton, Robert
    Block, Peter C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (01) : 114 - 118
  • [46] Balloon-expandable transapical transcatheter aortic valve implantation with or without predilation of the aortic valve: results of a multicentre registry
    Strauch, Justus
    Wendt, Daniel
    Diegeler, Anno
    Heimeshoff, Martin
    Hofmann, Steffen
    Holzhey, David
    Oertel, Frank
    Wahlers, Thorsten
    Kurucova, Jana
    Thoenes, Martin
    Deutsch, Cornelia
    Bramlage, Peter
    Schroefel, Holger
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (04) : 771 - 777
  • [47] Valve hemodynamic performance and myocardial strain after implantation of a third-generation, balloon-expandable, transcatheter aortic valve
    Fernandez-Santos, Sara
    Theron, Alexis
    Pibarot, Philippe
    Collart, Frederic
    Gilard, Martine
    Urena, Marina
    Hovorka, Tomas
    Kahlert, Philipp
    Zamorano Gomez, Jose Luis
    CARDIOLOGY JOURNAL, 2020, 27 (06) : 789 - 796
  • [48] Left Ventricular Outflow Tract Migration of a Balloon-Expandable Prosthesis During Transcatheter Aortic Valve Implantation Transcatheter Bailout Is Feasible, but not Safe
    Hachinohe, Daisuke
    Kobayashi, Ken
    Furugen, Azusa
    Koshima, Ryuji
    INTERNATIONAL HEART JOURNAL, 2017, 58 (02) : 290 - 293
  • [49] Conduction disorders after transcatheter aortic valve implantation: A comparison between SAPIEN 3 and SAPIEN 3 Ultra balloon-expandable valves
    Monizzi, Giovanni
    Olivares, Paolo
    Makmur, Giulio
    Fabbiocchi, Franco
    Grancini, Luca
    Mastrangelo, Angelo
    Ferrari, Cristina
    Galli, Stefano
    Montorsi, Piero
    Bartorelli, Antonio L. L.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [50] Quantitative Angiographic Assessment of Aortic Regurgitation after Transcatheter Aortic Valve Implantation among Three Balloon-Expandable Valves
    Kawashima, Hideyuki
    Wang, Rutao
    Mylotte, Darren
    Jagielak, Dariusz
    De Marco, Frederico
    Ielasi, Alfonso
    Onuma, Yoshinobu
    den Heijer, Peter
    Terkelsen, Christian Juhl
    Wijns, William
    Serruys, Patrick W.
    Soliman, Osama
    GLOBAL HEART, 2021, 16 (01)