Conduction delays after transcatheter aortic valve implantation with balloon-expandable prosthesis and high implantation technique

被引:0
|
作者
Fortunato Iacovelli
Giuseppe Giugliano
Donato Gerardi
Luigi Salemme
Angelo Cioppa
Armando Pucciarelli
Grigore Popusoi
Francesco Loizzi
Giancarlo Schettino
Stefano Favale
Francesco Solimene
Giovanni Esposito
Tullio Tesorio
Eugenio Stabile
机构
[1] Policlinico University Hospital,Division of University Cardiology, Cardiothoracic Department
[2] University of Naples “Federico II”,Division of Cardiology, Department of Advanced Biomedical Sciences
[3] “San Giovanni di Dio” Hospital,Division of Cardiology
[4] “Montevergine” Clinic,Interventional Cardiology Service
[5] Vivasure Medical Ltd,Electrophysiology Service
[6] “Montevergine” Clinic,Division of Cardiology, Cardiovascular Department
[7] “San Carlo” Regional Hospital,undefined
来源
Heart and Vessels | 2022年 / 37卷
关键词
Transcatheter aortic valve implantation; Permanent pacemaker implantation predictors; Electrophysiological study; Calcium volume;
D O I
暂无
中图分类号
学科分类号
摘要
Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation (p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification (p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.
引用
收藏
页码:337 / 346
页数:9
相关论文
共 50 条
  • [31] Impact of prosthesis-patient mismatch on hemodynamic and clinical outcomes after transcatheter aortic valve implantation with balloon-expandable valves
    Ewe, S. H.
    Delgado, V.
    Tamborini, G.
    Muratori, M.
    Pepi, M.
    Van der Kley, F.
    Fusari, M.
    Biglioli, P.
    Bax, J. J.
    Marsan, N. A.
    EUROPEAN HEART JOURNAL, 2011, 32 : 904 - 904
  • [32] Impact of Area Cover Index on the Incidence of Conduction Abnormalities after Implantation of Balloon-Expandable Aortic Prosthesis
    Jochheim, David
    Egger, Alexander
    Theiss, Hans
    Baquet, Moritz
    Greif, Martin
    Hausleiter, Joerg
    Mehilli, Julinda
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B207 - B208
  • [33] Impact of Prosthesis-Patient Mismatch on Hemodynamics During Exercise in Patients With Aortic Stenosis After Transcatheter Aortic Valve Implantation With a Balloon-Expandable Valve
    Kameshima, Haruka
    Izumo, Masaki
    Suzuki, Tomomi
    Ohara, Hiroshi
    Sato, Yukio
    Watanabe, Mika
    Kuwata, Shingo
    Okuyama, Kazuaki
    Kamijima, Ryo
    Takai, Manabu
    Kou, Seisyou
    Tanabe, Yasuhiro
    Harada, Tomoo
    Akashi, Yoshihiro J.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [34] Outcomes in patients with contained ruptures of the aortic annulus after transcatheter aortic valve implantation with balloon-expandable devices
    Breitbart, Philipp
    Minners, Jan
    Pache, Gregor
    Blanke, Philipp
    Reinoehl, Jochen
    Hansson, Nicolaj Christopher
    Norgaard, Bjarne L.
    Neumann, Franz-Josef
    Ruile, Philipp
    EUROINTERVENTION, 2017, 13 (11) : 1301 - 1303
  • [35] Aortic annulus eccentricity before and after transcatheter aortic valve implantation: comparison of balloon-expandable and self-expandable prostheses
    Schuhbaeck, A.
    Weingartner, C.
    Arnold, M.
    Schmid, J.
    Pflederer, T.
    Marwan, M.
    Nef, H.
    Uder, M.
    Weyand, M.
    Achenbach, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 31 - 32
  • [36] Atrioventricular Block After Transcatheter Balloon Expandable Aortic Valve Implantation
    Sinhal, Ajay
    Altwegg, Lukas
    Pasupati, Sanjeevan
    Humphries, Karin H.
    Allard, Michael
    Martin, Paul
    Cheung, Anson
    Ye, Jian
    Kerr, Charles
    Lichtenstein, Sam V.
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) : 305 - 309
  • [37] Incidence and predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with a balloon-expandable biosprosthesis in patients with bicuspid aortic valves
    Suygun, Hakan
    Kasapkara, Haci Ahmet
    Guney, Murat Can
    Polat, Melike
    Bozkurt, Engin
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2024, 20 (03): : 311 - 318
  • [38] Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis
    Pilgrim, Thomas
    Stortecky, Stefan
    Nietlispach, Fabian
    Heg, Dik
    Tueller, David
    Toggweiler, Stefan
    Ferrari, Enrico
    Noble, Stephane
    Maisano, Francesco
    Jeger, Raban
    Roffi, Marco
    Gruenenfelder, Juerg
    Huber, Christoph
    Wenaweser, Peter
    Windecker, Stephan
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (11):
  • [39] Transcatheter Aortic Valve Implantation Using the Slow Balloon Inflation Technique: Making Balloon-Expandable Valves Partially Repositionable
    Mok, Michael
    Dumont, Eric
    Doyle, Daniel
    Rodes-Cabau, Josep
    JOURNAL OF CARDIAC SURGERY, 2012, 27 (05) : 546 - 548
  • [40] Feasibility and safety of balloon-expandable transcatheter aortic valve implantation with moderate or without predilatation
    Abramowitz, Yigal
    Jilaihawi, Hasan
    Chakravarty, Tarun
    Kashif, Mohammad
    Matar, George
    Hariri, Babak
    Patel, Jigar
    Sharma, Rahul P.
    Cheng, Wen
    Makkar, Raj R.
    EUROINTERVENTION, 2016, 11 (10) : 1132 - 1139