Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images

被引:0
|
作者
M.E. Miquel
D.L.G. Hill
E.J. Baker
S.A. Qureshi
R.D.B. Simon
S.F. Keevil
R.S. Razavi
机构
[1] Cardiac MR Research Group,Department of Radiological Sciences
[2] King's College London 5th Floor,Department of Congenital Heart Disease
[3] Thomas Guy's House,Department of Cardiology
[4] Guy's Hospital,undefined
[5] Guy's and St Thomas' Hospital NHS Trust,undefined
[6] Guy's and St Thomas' Hospital NHS Trust,undefined
[7] East Wing,undefined
[8] St Thomas' Hospital,undefined
关键词
cardiac MRI; intra-cardiac echocardiography; rendering; segmentation; three-dimensional; trans-esophagal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2–3 mm apart) were acquired during breath holding. Depending on image quality, T1- or T2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.
引用
收藏
页码:239 / 254
页数:15
相关论文
共 50 条
  • [31] Three- and four-dimensional sonographic diagnosis of fetal intra-abdominal umbilical vein varix
    Bernadette S. Austria
    Uiko Hanaoka
    Miki Sato
    Toshiyuki Hata
    Journal of Medical Ultrasonics, 2014, 41 : 245 - 246
  • [32] Three- and four-dimensional sonographic diagnosis of fetal intra-abdominal umbilical vein varix
    Austria, Bernadette S.
    Hanaoka, Uiko
    Sato, Miki
    Hata, Toshiyuki
    JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (02) : 245 - 246
  • [33] EchoAnalyzer: software for the analysis of three- and four-dimensional echocardiographic data
    Wolf, I
    Mottl-Link, S
    Hastenteufel, M
    De Simone, R
    Meinzer, HP
    EUROPEAN HEART JOURNAL, 2002, 23 : 519 - 519
  • [34] Three- and four-dimensional Einstein-like manifolds and homogeneity
    Bueken, P
    Vanhecke, L
    GEOMETRIAE DEDICATA, 1999, 75 (02) : 123 - 136
  • [35] Three- and Four-Dimensional Einstein-like Manifolds and Homogeneity
    Peter Bueken
    Lieven Vanhecke
    Geometriae Dedicata, 1999, 75 : 123 - 136
  • [36] Representations of optical fibre communications in three- and four-dimensional spaces
    Rutigliano, Giuseppe Giulio
    Betti, Silvello
    Perrone, Pierluigi
    IET COMMUNICATIONS, 2019, 13 (20) : 3558 - 3564
  • [37] Three- and four-dimensional mapping of speech and language in patients with epilepsy
    Nakai, Yasuo
    Jeong, Jeong-won
    Brown, Erik C.
    Rothermel, Robert
    Kojima, Katsuaki
    Kambara, Toshimune
    Shah, Aashit
    Mittal, Sandeep
    Sood, Sandeep
    Asano, Eishi
    BRAIN, 2017, 140 : 1351 - 1370
  • [38] Effect of three- vs four-dimensional ultrasonography on maternal attachment
    Benzie, R. J.
    Starcevic, V.
    Viswasam, K.
    Kennedy, N. J.
    Mein, B. J.
    Wye, D. A.
    Martin, A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 51 (04) : 558 - 558
  • [39] THE RATIONALITY PROBLEM FOR THREE- AND FOUR-DIMENSIONAL PERMUTATIONAL GROUP ACTIONS
    Michailov, Ivo Michailov
    INTERNATIONAL JOURNAL OF ALGEBRA AND COMPUTATION, 2011, 21 (08) : 1317 - 1337
  • [40] Advancing orthodontic treatment planning - three- and four-dimensional imaging
    Quast, Anja
    Mouchoux, Jeremy
    Wiechens, Bernhard
    Meyer-Marcotty, Philipp
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2025, 57 (01): : 9 - 17