Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images

被引:0
|
作者
M.E. Miquel
D.L.G. Hill
E.J. Baker
S.A. Qureshi
R.D.B. Simon
S.F. Keevil
R.S. Razavi
机构
[1] Cardiac MR Research Group,Department of Radiological Sciences
[2] King's College London 5th Floor,Department of Congenital Heart Disease
[3] Thomas Guy's House,Department of Cardiology
[4] Guy's Hospital,undefined
[5] Guy's and St Thomas' Hospital NHS Trust,undefined
[6] Guy's and St Thomas' Hospital NHS Trust,undefined
[7] East Wing,undefined
[8] St Thomas' Hospital,undefined
关键词
cardiac MRI; intra-cardiac echocardiography; rendering; segmentation; three-dimensional; trans-esophagal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2–3 mm apart) were acquired during breath holding. Depending on image quality, T1- or T2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.
引用
收藏
页码:239 / 254
页数:15
相关论文
共 50 条
  • [21] Reconstruction and visualization of irregularly sampled three- and four-dimensional ultrasound data for cerebrovascular applications
    Meairs, S
    Beyer, J
    Hennerici, M
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (02): : 263 - 272
  • [22] Automated analysis of four-dimensional magnetic resonance images of the human aorta
    Johnson, Ryan K.
    Premraj, Senthil
    Patel, Sonali S.
    Walker, Nicholas
    Wahle, Andreas
    Sonka, Milan
    Scholz, Thomas D.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (05): : 571 - 578
  • [23] Statistical reconstruction of three-dimensional porous media from two-dimensional images
    Roberts, AP
    PHYSICAL REVIEW E, 1997, 56 (03) : 3203 - 3212
  • [24] Automated analysis of four-dimensional magnetic resonance images of the human aorta
    Ryan K. Johnson
    Senthil Premraj
    Sonali S. Patel
    Nicholas Walker
    Andreas Wahle
    Milan Sonka
    Thomas D. Scholz
    The International Journal of Cardiovascular Imaging, 2010, 26 : 571 - 578
  • [25] Three- and four-dimensional HDlive rendering images of normal and abnormal fetuses: pictorial essay
    Hata, Toshiyuki
    Hanaoka, Uiko
    Tenkumo, Chiaki
    Sato, Miki
    Tanaka, Hirokazu
    Ishimura, Mari
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2012, 286 (06) : 1431 - 1435
  • [26] Three- and four-dimensional HDlive rendering images of normal and abnormal fetuses: pictorial essay
    Toshiyuki Hata
    Uiko Hanaoka
    Chiaki Tenkumo
    Miki Sato
    Hirokazu Tanaka
    Mari Ishimura
    Archives of Gynecology and Obstetrics, 2012, 286 : 1431 - 1435
  • [27] Quantitative Evaluation of Four-Dimensional versus Three- Dimensional Reconstruction on XCAT Phantom Under Different Sampling Rates
    Al-Momani, Sajedah
    Elabed, Salma
    Dhou, Salam
    2019 3RD INTERNATIONAL CONFERENCE ON COMMUNICATIONS, SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA), 2019,
  • [28] A two-dimensional representation of four-dimensional gravitational waves
    Schmidt, HJ
    INTERNATIONAL JOURNAL OF MODERN PHYSICS D, 1998, 7 (02): : 215 - 223
  • [29] Test-retest and intra-observer repeatability of two-, three- and four-dimensional perineal ultrasound of pelvic floor muscle anatomy and function
    Braekken, Ingeborg Hoff
    Majida, Memona
    Ellstrom-Engh, Marie
    Dietz, Hans Peter
    Umek, Wolfgang
    Bo, Kari
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2008, 19 (02) : 227 - 235
  • [30] Thermodynamic shift from three- to two-dimensional systems
    Cuadros, F
    Mulero, A
    Okrasinski, W
    CHEMICAL PHYSICS, 1997, 218 (03) : 235 - 241