Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images

被引:0
|
作者
M.E. Miquel
D.L.G. Hill
E.J. Baker
S.A. Qureshi
R.D.B. Simon
S.F. Keevil
R.S. Razavi
机构
[1] Cardiac MR Research Group,Department of Radiological Sciences
[2] King's College London 5th Floor,Department of Congenital Heart Disease
[3] Thomas Guy's House,Department of Cardiology
[4] Guy's Hospital,undefined
[5] Guy's and St Thomas' Hospital NHS Trust,undefined
[6] Guy's and St Thomas' Hospital NHS Trust,undefined
[7] East Wing,undefined
[8] St Thomas' Hospital,undefined
关键词
cardiac MRI; intra-cardiac echocardiography; rendering; segmentation; three-dimensional; trans-esophagal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
The present study was designed to evaluate the feasibility and clinical usefulness of three-dimensional (3D) reconstruction of intra-cardiac anatomy from a series of two-dimensional (2D) MR images using commercially available software. Sixteen patients (eight with structurally normal hearts but due to have catheter radio-frequency ablation of atrial tachyarrhythmias and eight with atrial septal defects (ASD) due for trans-catheter closure) and two volunteers were imaged at 1T. For each patient, a series of ECG-triggered images (5 mm thick slices, 2–3 mm apart) were acquired during breath holding. Depending on image quality, T1- or T2-weighted spin-echo images or gradient-echo cine images were used. The 3D reconstruction was performed off-line: the blood pools within cardiac chambers and great vessels were semi-automatically segmented, their outer surface was extracted using a marching cube algorithm and rendered. Intra- and inter-observer variability, effect of breath-hold position and differences between pulse sequences were assessed by imaging a volunteer. The 3D reconstructions were assessed by three cardiologists and compared with the 2D MR images and with 2D and 3D trans-esophagal and intra-cardiac echocardiography obtained during interventions. In every case, an anatomically detailed 3D volume was obtained. In the two patients where a 3 mm interval between slices was used, the resolution was not as good but it was still possible to visualize all the major anatomical structures. Spin-echo images lead to reconstructions more detailed than those obtained from gradient-echo images. However, gradient-echo images are easier to segment due to their greater contrast. Furthermore, because images were acquired at least at ten points in the cardiac cycles for every slice it was possible to reconstruct a cine loop and, for example, to visualize the evolution of the size and margins of the ASD during the cardiac cycle. 3D reconstruction proved to be an effective way to assess the relationship between the different parts of the cardiac anatomy. The technique was useful in planning interventions in these patients.
引用
收藏
页码:239 / 254
页数:15
相关论文
共 50 条
  • [1] Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images
    Paul Steendijk
    The International Journal of Cardiovascular Imaging, 2003, 19 : 255 - 256
  • [2] Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images
    Miquel, ME
    Hill, DLG
    Baker, EJ
    Qureshi, SA
    Simon, RDB
    Keevil, SF
    Razavi, RS
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (03): : 239 - 254
  • [3] Three- and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images - Response
    Steendijk, P
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (03): : 255 - 256
  • [4] Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review
    Crandon, Saul
    Elbaz, Mohammed S. M.
    Westenberg, Jos J. M.
    van der Geest, Rob J.
    Plein, Sven
    Garg, Pankaj
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : 486 - 493
  • [5] Three- and Four-Dimensional Fetal Echocardiography
    Turan, Sifa
    Turan, Ozhan
    Baschat, Ahmet A.
    FETAL DIAGNOSIS AND THERAPY, 2009, 25 (04) : 361 - 372
  • [6] Three- and four-dimensional visualization of magnetic resonance imaging data sets in pediatric cardiology
    Vick III G.W.
    Pediatric Cardiology, 2000, 21 (1) : 27 - 36
  • [7] Three- and four-dimensional visualization of magnetic resonance imaging data sets in pediatric cardiology
    Vick, GW
    PEDIATRIC CARDIOLOGY, 2000, 21 (01) : 27 - 36
  • [8] Four-dimensional active appearance model segmentation of cardiac magnetic resonance images
    Zhang, Honghai
    Walker, Nicholas E.
    Thomas, Matthew T.
    Wahle, Andreas
    Scholz, Thomas D.
    Sonka, Milan
    CIRCULATION, 2006, 114 (18) : 727 - 727
  • [9] Three-dimensional object reconstruction from two-dimensional images
    Rockwood, AP
    Winget, J
    COMPUTER-AIDED DESIGN, 1997, 29 (04) : 279 - 285
  • [10] Perception of rigidity in three- and four-dimensional spaces
    He, Dongcheng
    Nguyen, Dat-Thanh
    Ogmen, Haluk
    Nishina, Shigeaki
    Yazdanbakhsh, Arash
    FRONTIERS IN PSYCHOLOGY, 2023, 14