Design and inelastic behavior of hyperbolic cooling tower

被引:2
|
作者
Hyun-ock Jang
Chang-shik Min
机构
[1] Dongguk Univ.,Dept. of Civil & Environmental Engrg.
关键词
reinforcement design in plate and shell; hyperbolic cooling tower; nonlinear inelastic behavior; finite element analysis;
D O I
10.1007/BF02829106
中图分类号
学科分类号
摘要
A design is performed for the hyperbolic cooling tower (Grand Gulf cooling tower) to check the design strength under a consistent design load; therefore, to verify the adequacy of the design algorithm developed. Based on the equilibrium consideration for the ultimate limit state of reinforcement in tension and cracked concrete in compression, an iterative numerical computational algorithm was developed. The design algorithm is implemented in a finite element analysis computer program developed by Mahmoud and Gupta. The amount of reinforcement is then determined at the center of each element by an elastic finite element analysis with the design ultimate load. Based on ultimate nonlinear analysis performed with the designed reinforcement, the analytically calculated ultimate load exceeded the design ultimate load from 26% to 63% for analyses with tension stiffening parameters of from 5 to 20. Since the effective tension stiffening would vary over the life of the shell due to environmental factors, a degree of uncertainty seems inevitable in calculating the actual failure load by numerical analysis. Even though the ultimate loads are strongly dependent on the tensile properties of concrete, the calculated ultimate loads are higher than the design ultimate loads for the design case. For the case designed, the design algorithm gives a lower bound on the design ultimate load with respect to the lower bound theorem. This shows the adequacy of the design algorithm developed, at least for the shell studied. The presented design algorithm for combined membrane and flexural forces can be evolved as a general design method for reinforced concrete plates and shells, through further studies involving the performance of many more designs and analyses of different shell configurations.
引用
收藏
页码:309 / 318
页数:9
相关论文
共 50 条
  • [1] Inelastic behavior of hyperbolic cooling tower
    Min, Chang
    Gupta, Ajay Kumar
    Journal of structural engineering New York, N.Y., 1993, 119 (07): : 2235 - 2255
  • [2] INELASTIC BEHAVIOR OF HYPERBOLIC COOLING-TOWER
    MIN, CS
    GUPTA, AK
    JOURNAL OF STRUCTURAL ENGINEERING, 1993, 119 (07) : 2235 - 2255
  • [3] INVESTIGATION ON HYPERBOLIC COOLING-TOWER ULTIMATE BEHAVIOR
    GUPTA, AK
    MAESTRINI, S
    ENGINEERING STRUCTURES, 1986, 8 (02) : 87 - 92
  • [4] Optimization Design of the GFRP Hyperbolic Cooling Tower Structure
    Zhang, Wenhua
    Meng, Chunling
    Li, Yunlong
    Wu, Nianpeng
    Liang, Tao
    2013 INTERNATIONAL CONFERENCE ON MECHANICAL AND AUTOMATION ENGINEERING (MAEE 2013), 2013, : 76 - 79
  • [5] INELASTIC LARGE-DISPLACEMENT BEHAVIOR AND BUCKLING OF COOLING-TOWER
    MAHMOUD, BEH
    GUPTA, AK
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (06): : 981 - 985
  • [6] A Simplified Procedure for the Structural Reinforcement Design of Hyperbolic Cooling Tower Shells
    Zhang, Jun-Feng
    Pei, Hao
    Li, Jie
    Ge, Yao-Jun
    Zhao, Lin
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (04) : 4155 - 4169
  • [7] A Simplified Procedure for the Structural Reinforcement Design of Hyperbolic Cooling Tower Shells
    Jun-Feng Zhang
    Hao Pei
    Jie Li
    Yao-Jun Ge
    Lin Zhao
    Arabian Journal for Science and Engineering, 2022, 47 : 4155 - 4169
  • [8] Blast Demolition of a hyperbolic cooling tower
    Werner, Diethelm
    Melzer, Rainer
    Bautechnik, 1998, 75 (04): : 205 - 212
  • [9] Analysis and Design of Strengthened Hyperbolic Cooling Tower by Using PDS Module in ANSYS
    Wei, Xinxin
    Wu, Yibin
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 3436 - 3440
  • [10] DRY-TYPE HYPERBOLIC COOLING TOWER
    ROGERS, P
    HELLER, L
    CIVIL ENGINEERING, 1972, 42 (10): : 56 - &