Effect of groundwater flow in vertical and horizontal fractures on borehole heat exchanger temperatures

被引:0
|
作者
S. Emad Dehkordi
Bo Olofsson
Robert A. Schincariol
机构
[1] University of Western Ontario,Department of Earth Sciences
[2] Royal Institute of Technology (KTH),Department of Land and Water Resources Engineering
关键词
Crystalline rock; FEFLOW; Fractured rock; Groundwater flow; Heat transport; Thermal response test;
D O I
暂无
中图分类号
学科分类号
摘要
Vertical closed loop systems, also known as borehole heat exchangers (BHEs), are a popular way of extracting the ground source heat energy. Primary factors affecting the performance of BHEs are the thermal and hydrogeological properties of the subsurface. Groundwater flow is known to potentially influence heat transport and system performance. The effect of groundwater movement is more commonly studied under homogeneous conditions. However, in heterogeneous fractured rocks, BHEs are more common than horizontal or open loops due to lack of sufficient soil layers and productive aquifers. The finite-element modelling shows that fractures can play an important role in BHE functioning. Especially, vertical open fractures (≥1 mm) near the borehole (≤10 m) can have a considerable impact. Although increase in fracture aperture continuously affects the subsurface and BHE temperatures, the increase in its effect progressively lessens. Depending on the distance and aperture, one major fracture influencing the BHE operation performance can be identified; yet a larger number of fractures may govern heat transport (thermal plume outline) and thermal recovery. Individually, horizontal fractures may have less influence than vertical fractures. However, as the density of horizontal fractures increases, their impact can be major, exceeding that of fracture aperture. In particular, we propose that measurements of rock thermal properties be combined with fracture mapping, to better analyse the thermal response testing results and integrate the configuration of fractures in design and layout of the BHE(s). This is particularly valid for (vertical) fractures not intersecting with the borehole.
引用
收藏
页码:479 / 491
页数:12
相关论文
共 50 条
  • [31] Temperatures and Heat Flows in a Soil Enclosing a Slinky Horizontal Heat Exchanger
    Neuberger, Pavel
    Adamovsky, Radomir
    Sed'ova, Michaela
    ENERGIES, 2014, 7 (02): : 972 - 987
  • [32] Heat extraction thermal response test in groundwater-filled borehole heat exchanger - Investigation of the borehole thermal resistance
    Gustafsson, A. -M.
    Westerlund, L.
    RENEWABLE ENERGY, 2011, 36 (09) : 2388 - 2394
  • [33] Study on heat transfer characteristic of vertical borehole heat exchanger at different geological structure
    地质结构分层中地埋管换热特性研究
    Li, Xiaozhao (lixz@nju.edu.cn), 1600, Science Press (41): : 290 - 294
  • [34] Investigation of buoyancy effects on heat transfer between a vertical borehole heat exchanger and the ground
    Sharqawy, Mostafa H.
    Badr, Hassan M.
    Mokheimer, Esmail M.
    GEOTHERMICS, 2013, 48 : 52 - 59
  • [35] Numerical investigation on the influence of groundwater flow on long-term heat extraction performance of deep borehole heat exchanger array
    Yang, Xiong
    Cai, Wanlong
    Li, Yongpeng
    Wang, Ming
    Kong, Yanlong
    Wang, Fenghao
    Chen, Chaofan
    Geothermal Energy, 2024, 12 (01)
  • [36] Study on the Coupled Heat Transfer Model Based on Groundwater Advection and Axial Heat Conduction for the Double U-Tube Vertical Borehole Heat Exchanger
    Zhang, Linlin
    Shi, Zhonghua
    Yuan, Tianhao
    SUSTAINABILITY, 2020, 12 (18)
  • [37] Preliminary Investigation of the Effect of Horizontal Piping on the Performance of a Vertical Ground Heat Exchanger System
    Cullin, James R.
    Spitler, Jeffrey D.
    Lee, Edwin
    ASHRAE TRANSACTIONS 2013, VOL 119, PT 2, 2013, 119 : 302 - 311
  • [38] Long-term performance of large borehole heat exchanger fields with unbalanced seasonal loads and groundwater flow
    Zanchini, Enzo
    Lazzari, Stefano
    Priarone, Antonella
    ENERGY, 2012, 38 (01) : 66 - 77
  • [39] Refrigerant distribution in a parallel flow heat exchanger having vertical headers and heated horizontal tubes
    Byun, H. W.
    Kim, N. H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2011, 35 (06) : 920 - 932
  • [40] Long-term performance of large borehole heat exchanger fields with unbalanced seasonal loads and groundwater flow
    Dipartimento di Ingegneria Energetica Nucleare e del Controllo Ambientale, Università di Bologna, Viale Risorgimento 2, I-40136 Bologna, Italy
    不详
    Energy, 1 (66-77):