Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2

被引:0
|
作者
Francesco Trepiccione
Francesco Maria Iena
Laura Catalini
Francesco Martino Carpi
Mogens Koed
Sebastian Frische
机构
[1] University of Aarhus,Department of Biomedicine
[2] University of Campania “Luigi Vanvitelli”,Department of Cardio
[3] University of Camerino,Thoracic and Respiratory Science
关键词
Acid/base status; Bicarbonate; NDIR; Urine; Total CO;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study is to describe a low-cost and simply made instrument capable of measuring the total CO2 content of microliter volumes of biological fluids utilizing a commercially available CO2 sensor based on a NDIR detector. The described instrument is based on transformation of dissolved HCO3− to CO2 by acidification and subsequent measurement of the produced CO2. The instrument has a linear response in the range 0.025–10 μmol HCO3−, which enables measurements in fresh urine and plasma samples down to 5 μl. The values from plasma were compared to measurements made on 65 μl whole blood in an automatic blood gas analyzer and found not to differ significantly. Compared to currently commercially available instruments applying the same principles to measure total CO2, this study provides a simple and robust alternative which even can be used on smaller sample volumes.
引用
收藏
页码:1267 / 1275
页数:8
相关论文
共 50 条
  • [41] Nonphotosynthetic Biological CO2 Reduction
    Gonzales, Jake N.
    Matson, Morgan M.
    Atsumi, Shota
    BIOCHEMISTRY, 2019, 58 (11) : 1470 - 1477
  • [42] Ambient CO2 Measurement Using Raman Lidar
    Kim, Daewon
    Lee, Hanlim
    Park, Junsung
    Choi, Wonei
    Yang, Jiwon
    Kang, Hyeongwoo
    KOREAN JOURNAL OF REMOTE SENSING, 2019, 35 (06) : 1187 - 1195
  • [43] Biological fossil CO2 mitigation
    Hughes, E
    Benemann, JR
    ENERGY CONVERSION AND MANAGEMENT, 1997, 38 : S467 - S473
  • [44] CO2 MEASUREMENT USING A 550 EXPRESS ANALYZER
    SHAMBERGER, RJ
    MULLINS, M
    REASON, C
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1069 - 1069
  • [45] NEW INFRARED SYSTEM FOR MEASUREMENT OF CO2, CO, H2O FROM AIRCRAFT
    SCHMITT, R
    ATMOSPHERIC ENVIRONMENT, 1975, 9 (09) : 865 - 866
  • [46] Infrared evanescent-field microscope using CO2 laser for reflectance measurement
    Nakano, T.
    Kawata, S.
    Optik (Jena), 1993, 94 (04): : 159 - 162
  • [47] EFFECT OF CO2 ON THE BUOYANCY OF GEOTHERMAL FLUIDS
    STRAUS, JM
    SCHUBERT, G
    GEOPHYSICAL RESEARCH LETTERS, 1979, 6 (01) : 5 - 8
  • [48] Infrared observation of a new mixed trimer, CO - (CO2)2
    Barclay, A. J.
    McKellar, A. R. W.
    Moazzen-Ahmadi, N.
    CHEMICAL PHYSICS LETTERS, 2017, 677 : 127 - 130
  • [49] Organometallic CO2 complexes in supercritical CO2:: a time-resolved infrared study
    George, MW
    Grills, DC
    Sun, XZ
    Poliakoff, M
    ADVANCES IN CHEMICAL CONVERSIONS FOR MITIGATING CARBON DIOXIDE, 1998, 114 : 255 - 260
  • [50] Effects of Supercritical CO2 Fluids on Pore Morphology of Coal: Implications for CO2 Geological Sequestration
    Zhang, Kaizhong
    Cheng, Yuanping
    Jin, Kan
    Guo, Haijun
    Liu, Qingquan
    Dong, Jun
    Li, Wei
    ENERGY & FUELS, 2017, 31 (05) : 4731 - 4741