Intercentre Reproducibility of Magnetic Resonance T2* Measurements of Myocardial Iron in Thalassaemia

被引:0
|
作者
Mark A. Westwood
David N. Firmin
Matta Gildo
Galanello Renzo
Gotsis Stathis
Karagiorga Markissia
Berdoukas Vasili
Dudley J. Pennell
机构
[1] Royal Brompton Hospital,CMR Unit
[2] Hospital Brotzu,Department of Radiology
[3] Department of Thalassemia and other Hematologic Diseases,Department of Magnetic Resonance
[4] Institute EUROMEDICA-ENCEPHALOS,Department of Haematology
[5] Agia Sophia Childrens hospital,undefined
关键词
anemia; cardiomyopathy; heart failure; magnetic resonance imaging; reproducibility; thalassemia;
D O I
暂无
中图分类号
学科分类号
摘要
In transfusion-dependent thalassemia major, iron-induced cardiomyopathy is the predominant cause of morbidity and mortality. Assessment of myocardial iron loading using MRI gradient echo T2* measurements have been described, but has only been performed at one centre in London. We assessed the transferability of this method by comparing the results from three different MR scanners in three different countries. Ten patients with thalassemia major underwent myocardial T2* assessment using a Siemens Sonata Scanner in London. Patients were also scanned with either a similar T2* sequence on a GE Systems CVI scanner in Athens, or a GE Systems signa echospeed scanner in Cagliari. Two scans were performed at the respective site in all patients to assess interstudy reproducibility at each site. The mean difference and coefficient of variability for the heart between scanners was 0.08 ms and 9.7% between London and Athens; and 0.30 ms and 1.6% between London and Cagliari. The interstudy mean difference and coefficient of variability for the heart in Athens was 0.6 ms and 3.5%, and 0.2 ms and 2.4% in Cagliari. In conclusion, the myocardial iron estimations were consistent between the three centres with scanners of differing manufacture, suggesting that this technique may have widespread application in the assessment of patients with iron overload conditions such as thalassaemia.
引用
收藏
页码:531 / 538
页数:7
相关论文
共 50 条
  • [1] Intercentre reproducibility of magnetic resonance T2*measurements of myocardial iron in thalassaemia
    Westwood, MA
    Firmin, DN
    Gildo, M
    Renzo, G
    Stathis, G
    Markissia, K
    Vasili, B
    Pennell, DJ
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (05): : 531 - 538
  • [2] Interscanner reproducibility of cardiovascular magnetic resonance T2*measurements of tissue iron in thalassemia
    Westwood, MA
    Anderson, LJ
    Firmin, DN
    Gatehouse, PD
    Lorenz, CH
    Wonke, B
    Pennell, DJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (05) : 616 - 620
  • [3] T2*magnetic resonance and myocardial iron in thalassemia
    Pennell, DJ
    COOLEY'S ANEMIA EIGHTH SYMPOSIUM, 2005, 1054 : 373 - 378
  • [4] Worldwide survey of T2* cardiovascular magnetic resonance in Thalassaemia
    Carpenter J.-P.
    He T.
    Kirk P.
    Anderson L.
    Porter J.B.
    Walker M.
    Galanello R.
    Danjou F.
    Forni G.
    Kattamis A.
    Ladis V.
    Drossou M.
    Vini D.
    Michos A.
    Perifanis V.
    Hazirolan T.
    Almeida A.
    Aydinok Y.
    Rangelova M.
    El-Beshlawy A.
    Elalfy M.
    Alnasser I.
    Daar S.
    Fernandes J.D.L.
    Pennell D.J.
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [5] Evaluation of myocardial iron overload by T2* cardiovascular magnetic resonance imaging
    Cheong, B
    Huber, S
    Muthupillai, R
    Flamm, SD
    TEXAS HEART INSTITUTE JOURNAL, 2005, 32 (03): : 448 - 449
  • [6] Myocardial iron assessment by T2* cardiovascular magnetic resonance at 3 Tesla
    Mohammed H Alam
    Gillian C Smith
    Taigang He
    John Paul Carpenter
    Arun J Baksi
    Ricardo Wage
    Peter Drivas
    Karen Symmonds
    David Firmin
    Dudley J Pennell
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [7] On T2*Magnetic Resonance and Cardiac Iron
    Carpenter, John-Paul
    He, Taigang
    Kirk, Paul
    Roughton, Michael
    Anderson, Lisa J.
    de Noronha, Sofia V.
    Sheppard, Mary N.
    Porter, John B.
    Walker, J. Malcolm
    Wood, John C.
    Galanello, Renzo
    Forni, Gianluca
    Catani, Gualtiero
    Matta, Gildo
    Fucharoen, Suthat
    Fleming, Adam
    House, Michael J.
    Black, Greg
    Firmin, David N.
    St Pierre, Timothy G.
    Pennell, Dudley J.
    CIRCULATION, 2011, 123 (14) : 1519 - 1528
  • [8] T2* Magnetic Resonance: Iron and Gold
    Pennell, Dudley J.
    JACC-CARDIOVASCULAR IMAGING, 2008, 1 (05) : 579 - 581
  • [9] EVALUATION OF RENAL IRON DEPOSITION USING T2☆ MAGNETIC RESONANCE IMAGING IN THALASSAEMIA (LARGE COHORT STUDY)
    Afshan, Shirkavand
    Parisa, Mokhtari Hesari
    Shahram, Akhlaghpoor
    Bahar, Mansoori
    Azita, Azarkeivan
    Mozhgan, Hashemieh
    HAEMATOLOGICA, 2017, 102 : 76 - 77
  • [10] Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload
    Anderson, LJ
    Holden, S
    Davis, B
    Prescott, E
    Charrier, CC
    Bunce, NH
    Firmin, DN
    Wonke, B
    Porter, J
    Walker, JM
    Pennell, DJ
    EUROPEAN HEART JOURNAL, 2001, 22 (23) : 2171 - 2179