Intercentre Reproducibility of Magnetic Resonance T2* Measurements of Myocardial Iron in Thalassaemia

被引:0
|
作者
Mark A. Westwood
David N. Firmin
Matta Gildo
Galanello Renzo
Gotsis Stathis
Karagiorga Markissia
Berdoukas Vasili
Dudley J. Pennell
机构
[1] Royal Brompton Hospital,CMR Unit
[2] Hospital Brotzu,Department of Radiology
[3] Department of Thalassemia and other Hematologic Diseases,Department of Magnetic Resonance
[4] Institute EUROMEDICA-ENCEPHALOS,Department of Haematology
[5] Agia Sophia Childrens hospital,undefined
关键词
anemia; cardiomyopathy; heart failure; magnetic resonance imaging; reproducibility; thalassemia;
D O I
暂无
中图分类号
学科分类号
摘要
In transfusion-dependent thalassemia major, iron-induced cardiomyopathy is the predominant cause of morbidity and mortality. Assessment of myocardial iron loading using MRI gradient echo T2* measurements have been described, but has only been performed at one centre in London. We assessed the transferability of this method by comparing the results from three different MR scanners in three different countries. Ten patients with thalassemia major underwent myocardial T2* assessment using a Siemens Sonata Scanner in London. Patients were also scanned with either a similar T2* sequence on a GE Systems CVI scanner in Athens, or a GE Systems signa echospeed scanner in Cagliari. Two scans were performed at the respective site in all patients to assess interstudy reproducibility at each site. The mean difference and coefficient of variability for the heart between scanners was 0.08 ms and 9.7% between London and Athens; and 0.30 ms and 1.6% between London and Cagliari. The interstudy mean difference and coefficient of variability for the heart in Athens was 0.6 ms and 3.5%, and 0.2 ms and 2.4% in Cagliari. In conclusion, the myocardial iron estimations were consistent between the three centres with scanners of differing manufacture, suggesting that this technique may have widespread application in the assessment of patients with iron overload conditions such as thalassaemia.
引用
收藏
页码:531 / 538
页数:7
相关论文
共 50 条
  • [41] Multicenter validation of the magnetic resonance T2* technique for quantification of pancreatic iron
    Antonella Meloni
    Daniele De Marchi
    Laura Pistoia
    Emanuele Grassedonio
    Giuseppe Peritore
    Paolo Preziosi
    Gennaro Restaino
    Riccardo Righi
    Ada Riva
    Stefania Renne
    Nicolò Schicchi
    Antonino Vallone
    Angelo Peluso
    Calogera Gerardi
    Vincenzo Positano
    Alessia Pepe
    European Radiology, 2019, 29 : 2246 - 2252
  • [42] No evidence for myocardial iron overload in multitransfused patients with myelodysplastic syndrome using cardiac magnetic resonance T2*technique
    Konen, Eli
    Ghoti, Husam
    Goitein, Orly
    Winder, Asher
    Kushnir, Tammi
    Eshet, Yael
    Rachmilewitz, Eliezer
    AMERICAN JOURNAL OF HEMATOLOGY, 2007, 82 (11) : 1013 - 1016
  • [43] Multislice multiecho T2*cardiac magnetic resonance can detect heterogeneous myocardial iron distribution in thalassemia patients
    Pepe, A.
    Positano, V.
    Santarelli, M. F.
    Meloni, A.
    Favilli, B.
    De Marchi, D.
    Keilberg, P.
    Caruso, V.
    Landini, L.
    Lombardi, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 487 - 487
  • [44] A single breath-hold multiecho T2*cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload
    Westwood, M
    Anderson, LJ
    Firmin, DN
    Gatehouse, PD
    Charrier, CC
    Wonke, B
    Pennell, DJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) : 33 - 39
  • [45] Myocardial iron overload assessment by T2*magnetic resonance imaging in adult transfusion dependent patients with acquired anemias
    Di Tucci, Anna Angela
    Matta, Gildo
    Deplano, Simona
    Gabbas, Attilio
    Depau, Cristina
    Derudas, Daniele
    Caocci, Giovanni
    Agus, Annalisa
    Angelucci, Emanuele
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 (09): : 1385 - 1388
  • [46] Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging
    Yoo, Yeon Hwa
    Yoon, Choon-Sik
    Eun, Na Lae
    Hwang, Moon-Jung
    Yoo, Hanna
    Peters, Robert D.
    Chung, Tae-Sub
    Lee, Young Han
    Suh, Jin-Suck
    Kim, Sungjun
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (06) : 903 - 911
  • [47] Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance
    Topriceanu, Constantin-Cristian
    Fornasiero, Massimiliano
    Seo, Han
    Webber, Matthew
    Keenan, Kathryn E. E.
    Stupic, Karl F. F.
    Bruehl, Ruediger
    Ittermann, Bernd
    Price, Kirsty
    McGrath, Louise
    Pang, Wenjie
    Hughes, Alun D. D.
    Nezafat, Reza
    Kellman, Peter
    Pierce, Iain
    Moon, James C. C.
    Captur, Gabriella
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)
  • [48] Developing a medical device-grade T2 phantom optimized for myocardial T2 mapping by cardiovascular magnetic resonance
    Constantin-Cristian Topriceanu
    Massimiliano Fornasiero
    Han Seo
    Matthew Webber
    Kathryn E. Keenan
    Karl F. Stupic
    Rüdiger Bruehl
    Bernd Ittermann
    Kirsty Price
    Louise McGrath
    Wenjie Pang
    Alun D. Hughes
    Reza Nezafat
    Peter Kellman
    Iain Pierce
    James C. Moon
    Gabriella Captur
    Journal of Cardiovascular Magnetic Resonance, 25
  • [49] A T2/T2 magnetic resonance imaging (MRI) study of iron overload in hemopoietic stem cell transplant recipients
    Au, W. Y.
    Lam, W.
    Chu, W.
    Tam, S.
    Wong, W. K.
    Pennell, D. J.
    Lie, A. K.
    Liang, R.
    AMERICAN JOURNAL OF HEMATOLOGY, 2007, 82 (06) : 598 - 598
  • [50] Dark blood versus bright blood T2*acquisition in cardiovascular magnetic resonance (CMR) for thalassaemia major (TM) patients: Evaluation of feasibility, reproducibility and image quality
    Liguori, Carlo
    Di Giampietro, Ilenia
    Pitocco, Francesca
    De Vivo, Aldo Eros
    Schena, Emiliano
    Mortato, Luca
    Pirro, Federica
    Cianciulli, Paolo
    Zobel, Bruno Beomonte
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (01) : E8 - E14