T2*magnetic resonance and myocardial iron in thalassemia

被引:130
|
作者
Pennell, DJ [1 ]
机构
[1] Royal Brompton Hosp, CMR Unit, London SW3 6NP, England
来源
关键词
magnetic resonance; MR; heart; iron overload; siderosis; chelation; deferoxamine; deferiprone; heart failure; ejection fraction; mortality;
D O I
10.1196/annals.1345.045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Magnetic resonance T2* values of the myocardium are directly related to tissue iron levels. Minor effects from myocardial oxygenation and fibrosis are overwhelmed by the highly dominant iron effect in clinically relevant levels of myocardial iron overload. Myocardial T2* values less than 20 ms indicate iron overload, and this is considered severe when T2* is less than 10 ms. Decreasing myocardial T2* levels are associated with systolic and diastolic ventricular dysfunction. Most recorded cases of heart failure in thalassemia to date have occurred in patients with very low T2* values (in the severe range). Exceptions to this have occurred in patients with other causes of heart failure such as concomitant congenital heart disease. In patients presenting with heart failure who undergo aggressive chelation with continuous intravenous deferoxamine, longitudinal studies show that myocardial T2* increases, and this is accompanied by increases in ejection fraction and relief of heart failure. In cross-sectional studies, the myocardial T2* and ejection fraction of patients on deferiprone was superior to that of patients on deferoxamine. Randomized controlled prospective trials comparing these two drugs for their action in clearing myocardial iron, as measured by myocardial T2*, are under way and should report in 2005/2006. These trials will clarify the role of different chelators in the management of myocardial iron overload and may be valuable in reducing the toll of death in thalassemia from heart failure.
引用
收藏
页码:373 / 378
页数:6
相关论文
共 50 条
  • [1] Multislice Multiecho T2*Cardiovascular Magnetic Resonance Detects Heterogeneous Myocardial Iron Distribution in Thalassemia Patients
    Positano, Vincenzo
    Pepe, Alessia
    Ramazzotti, Anna
    Santarelli, Maria Filomena
    Meloni, Antonella
    Spasiano, Anna
    Borgna-Pignatti, Caterina
    Cianciulli, Paolo
    Capra, Marcello
    Lai, Maria-Eliana
    Maggio, Aurelio
    Lombardi, Massimo
    Landini, Luigi
    [J]. BLOOD, 2008, 112 (11) : 1320 - 1320
  • [2] Multislice multiecho T2*cardiac magnetic resonance can detect heterogeneous myocardial iron distribution in thalassemia patients
    Pepe, A.
    Positano, V.
    Santarelli, M. F.
    Meloni, A.
    Favilli, B.
    De Marchi, D.
    Keilberg, P.
    Caruso, V.
    Landini, L.
    Lombardi, M.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 487 - 487
  • [3] A T2*magnetic resonance imaging study of pancreatic iron overload in thalassemia major
    Au, Wing-Yan
    Lam, Wynnie Wai-Man
    Chu, Winnie
    Tam, Sidney
    Wong, Wai-Keng
    Liang, Raymond
    Ha, Shau-Yin
    [J]. HAEMATOLOGICA, 2007, 93 (01) : 116 - 119
  • [4] Interscanner reproducibility of cardiovascular magnetic resonance T2*measurements of tissue iron in thalassemia
    Westwood, MA
    Anderson, LJ
    Firmin, DN
    Gatehouse, PD
    Lorenz, CH
    Wonke, B
    Pennell, DJ
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (05) : 616 - 620
  • [5] Intercentre reproducibility of magnetic resonance T2*measurements of myocardial iron in thalassaemia
    Westwood, MA
    Firmin, DN
    Gildo, M
    Renzo, G
    Stathis, G
    Markissia, K
    Vasili, B
    Pennell, DJ
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (05): : 531 - 538
  • [6] Evaluation of myocardial iron overload by T2* cardiovascular magnetic resonance imaging
    Cheong, B
    Huber, S
    Muthupillai, R
    Flamm, SD
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2005, 32 (03): : 448 - 449
  • [7] Intercentre Reproducibility of Magnetic Resonance T2* Measurements of Myocardial Iron in Thalassaemia
    Mark A. Westwood
    David N. Firmin
    Matta Gildo
    Galanello Renzo
    Gotsis Stathis
    Karagiorga Markissia
    Berdoukas Vasili
    Dudley J. Pennell
    [J]. The International Journal of Cardiovascular Imaging, 2005, 21 : 531 - 538
  • [8] Myocardial iron assessment by T2* cardiovascular magnetic resonance at 3 Tesla
    Mohammed H Alam
    Gillian C Smith
    Taigang He
    John Paul Carpenter
    Arun J Baksi
    Ricardo Wage
    Peter Drivas
    Karen Symmonds
    David Firmin
    Dudley J Pennell
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [9] On T2*Magnetic Resonance and Cardiac Iron
    Carpenter, John-Paul
    He, Taigang
    Kirk, Paul
    Roughton, Michael
    Anderson, Lisa J.
    de Noronha, Sofia V.
    Sheppard, Mary N.
    Porter, John B.
    Walker, J. Malcolm
    Wood, John C.
    Galanello, Renzo
    Forni, Gianluca
    Catani, Gualtiero
    Matta, Gildo
    Fucharoen, Suthat
    Fleming, Adam
    House, Michael J.
    Black, Greg
    Firmin, David N.
    St Pierre, Timothy G.
    Pennell, Dudley J.
    [J]. CIRCULATION, 2011, 123 (14) : 1519 - 1528
  • [10] T2* Magnetic Resonance: Iron and Gold
    Pennell, Dudley J.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2008, 1 (05) : 579 - 581