Effect of surface topography on pull-out strength of cortical screw after ultrasonic bone drilling: an in vitro study

被引:0
|
作者
Raj Agarwal
Vivek Jain
Vishal Gupta
Sanjai Saxena
Vagish Dwibedi
机构
[1] Thapar Institute of Engineering and Technology,Department of Mechanical Engineering
[2] Thapar Institute of Engineering and Technology,Department of Biotechnology
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2020年 / 42卷
关键词
Rotary ultrasonic bone drilling; Surface roughness; Microcracks; SBF; Pull-out strength;
D O I
暂无
中图分类号
学科分类号
摘要
Drilling of bone is required to repair and align the bone when faced with a major fracture. The screw and implant are used for fixing the fractured part of the bone. The failure of osteosynthesis is due to strength between the bone and screw, which majorly depends upon the pull-out strength of the cortical screw. Pull-out strength is the force required to pull a screw out of its foundation from the bone. After the fixation of cortical screws, the major forces acting on the fixation of the screw and the implanted device in the bone. Therefore, it needs to make sure that the screw must fit into the place and grasp the bone within the drilled hole. The intended focus of this research is to see the effect of surface roughness induced during the bone drilling operation on pull-out strength with rotary ultrasonic bone drilling (RUBD) and standard conventional bone drilling (CBD). This is observed that a drilled hole in a bone exhibits greater pull-out strength with more surface roughness because more anchoring is provided by the roughened surface. Also, the apatite formation of the bone shows the biocompatible nature of porcine bone in the simulated body fluid (SBF) solution. RUBD using different grit size in a hollow drilling burr resulted that coarse abrasive have maximum effort for higher surface roughness. Furthermore, the higher surface texture provides a better bone growth rate as it provides peaks for branching and nucleation when preserved in SBF. RUBD provides precise cutting to the bone as compared to CBD. On the 28th day of the bone-screw samples to be immersed in SBF results 42.82% higher pull-out strength of screw in case of RUBD as compared to CBD.
引用
收藏
相关论文
共 50 条
  • [41] Does the anchorage form and depth influence the pull-out strength of screws from bone cement? An experimental study
    Heller, KD
    Zilkens, KW
    Hammer, J
    Cohen, B
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (1-2) : 88 - 91
  • [42] Development of bioactivity and pull-out torque control technology on Ti implant surface and its application for cold thread rolled bone screw
    Yoshida, Yoshinori
    Kuroda, Kensuke
    Ichino, Ryoichi
    Hayashi, Norishige
    Ogihara, Naofumi
    Nonaka, Yoshio
    11TH INTERNATIONAL CONFERENCE ON TECHNOLOGY OF PLASTICITY, ICTP 2014, 2014, 81 : 340 - 345
  • [43] Is the pull-out force of the Meniscus Arrow in bone affected by the inward curling of the barbs during biodegradation? An in vitro study
    Wouters, Diederick B.
    Burgerhof, Johannes G. M.
    de Hosson, Jeff T. M.
    Bos, Rudolf R. M.
    MEDICAL SCIENCE MONITOR, 2009, 15 (04): : BR95 - BR98
  • [44] Relation between diameter of a lateral screw and pull-out strength in distal clavicle fracture in plates with different geometry: A cadaveric biomechanical study
    Yoon, Tae-Hwan
    Choi, Yun-Rak
    Ju, Hun-Jin
    Chun, Yong-Min
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (07) : 1577 - 1583
  • [45] Effect of surface treatment, ferrule height, and luting agent type on pull-out bond strength of monolithic zirconia endocrowns
    Buyukerkmen, Emine B.
    Bozkurt, Durmus A.
    Terlemez, Arslan
    JOURNAL OF ORAL SCIENCE, 2022, 64 (04) : 279 - 285
  • [46] Axial pull-out strength of 3.5 cortical and 4.0 cancellous bone screws placed in canine proximal tibias using manual and power tapping
    Demko, J. L.
    Soniat, M. E.
    Elder, S.
    McLaughlin, R.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2008, 21 (04) : 323 - 328
  • [47] Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength
    Wichmann, Julian L.
    Booz, Christian
    Wesarg, Stefan
    Bauer, Ralf W.
    Kerl, J. Matthias
    Fischer, Sebastian
    Lehnert, Thomas
    Vogl, Thomas J.
    Khan, M. Fawad
    Kafchitsas, Konstantinos
    EUROPEAN RADIOLOGY, 2015, 25 (06) : 1714 - 1720
  • [48] A comparison of the thermal properties of 2-and 3-fluted drills and the effects on bone cell viability and screw pull-out strength in an ovine model
    Bertollo, Nicky
    Milne, Hadley R. M.
    Ellis, Liam P.
    Stephens, Paul C.
    Gillies, Ronald M.
    Walsh, William R.
    CLINICAL BIOMECHANICS, 2010, 25 (06) : 613 - 617
  • [49] Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength
    Julian L. Wichmann
    Christian Booz
    Stefan Wesarg
    Ralf W. Bauer
    J. Matthias Kerl
    Sebastian Fischer
    Thomas Lehnert
    Thomas J. Vogl
    M. Fawad Khan
    Konstantinos Kafchitsas
    European Radiology, 2015, 25 : 1714 - 1720
  • [50] Comparison of pedicle screw pull-out forces using two vertebral bone material mappings: a patient-specific finite element modeling study
    Rouyin, Alireza
    Salmani, Mohammad Javad
    Arjmand, Navid
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 33 - 38