Effect of surface topography on pull-out strength of cortical screw after ultrasonic bone drilling: an in vitro study

被引:0
|
作者
Raj Agarwal
Vivek Jain
Vishal Gupta
Sanjai Saxena
Vagish Dwibedi
机构
[1] Thapar Institute of Engineering and Technology,Department of Mechanical Engineering
[2] Thapar Institute of Engineering and Technology,Department of Biotechnology
来源
Journal of the Brazilian Society of Mechanical Sciences and Engineering | 2020年 / 42卷
关键词
Rotary ultrasonic bone drilling; Surface roughness; Microcracks; SBF; Pull-out strength;
D O I
暂无
中图分类号
学科分类号
摘要
Drilling of bone is required to repair and align the bone when faced with a major fracture. The screw and implant are used for fixing the fractured part of the bone. The failure of osteosynthesis is due to strength between the bone and screw, which majorly depends upon the pull-out strength of the cortical screw. Pull-out strength is the force required to pull a screw out of its foundation from the bone. After the fixation of cortical screws, the major forces acting on the fixation of the screw and the implanted device in the bone. Therefore, it needs to make sure that the screw must fit into the place and grasp the bone within the drilled hole. The intended focus of this research is to see the effect of surface roughness induced during the bone drilling operation on pull-out strength with rotary ultrasonic bone drilling (RUBD) and standard conventional bone drilling (CBD). This is observed that a drilled hole in a bone exhibits greater pull-out strength with more surface roughness because more anchoring is provided by the roughened surface. Also, the apatite formation of the bone shows the biocompatible nature of porcine bone in the simulated body fluid (SBF) solution. RUBD using different grit size in a hollow drilling burr resulted that coarse abrasive have maximum effort for higher surface roughness. Furthermore, the higher surface texture provides a better bone growth rate as it provides peaks for branching and nucleation when preserved in SBF. RUBD provides precise cutting to the bone as compared to CBD. On the 28th day of the bone-screw samples to be immersed in SBF results 42.82% higher pull-out strength of screw in case of RUBD as compared to CBD.
引用
收藏
相关论文
共 50 条
  • [31] Relationship between pull-out strength and oscillation angle in bipolar cups: an in vitro study.
    Kaku, Nobuhiro
    Tabata, Tomonori
    Tsumura, Hiroshi
    JOURNAL OF ORTHOPAEDIC SURGERY, 2016, 24 (02) : 209 - 215
  • [32] Screw insertion torque as parameter to judge the fixation. Assessment of torque and pull-out strength in different bone densities and screw-pitches
    Addevico, Francesco
    Morandi , Massimo
    Scaglione, Michelangelo
    Solitro, Giovanni F.
    CLINICAL BIOMECHANICS, 2020, 72 : 130 - 135
  • [33] Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model
    Krishnan, Venkatesh
    Varghese, Vicky
    Kumar, Gurunathan Saravana
    ASIAN SPINE JOURNAL, 2016, 10 (03) : 414 - 421
  • [34] Influence of bone quality and pedicle screw design on the fixation strength during Axial Pull-out test: A 2D Axisymmetric FE study
    Makaram, Harikrishna
    Swaminathan, Ramakrishnan
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4924 - 4927
  • [35] BOTH TBS AND VOLUMETRIC BMD ARE ASSOCIATED WITH PEDICLE SCREW PULL-OUT STRENGTH: AN EX-VIVO FEASIBILITY STUDY
    Lelong, C.
    Le Nost, P.
    Choisne, J.
    Valiadis, J. -M.
    Winzenrieth, R.
    Kolta, S.
    Skalli, W.
    OSTEOPOROSIS INTERNATIONAL, 2017, 28 : S527 - S528
  • [36] Pull-Out Strength Comparison Among Conventional Pedicle Screw, Cortical lnfero-Superior, and Cortical Supero-lnferior Trajectories in Yorkshire Porcine Lumbar Spines: A Biomechanical Study
    Tobing, Singkat Dohar A. L.
    Wisnubaroto, Rizky P.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2020, 14 (04): : 580 - 584
  • [37] Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles
    Meira, Thiago Martins
    Tanaka, Orlando Motohiro
    Ronsani, Maiara Medeiros
    Maruo, Ivan Toshio
    Guariza-Filho, Odilon
    Camargo, Elisa Souza
    Maruo, Hiroshi
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (06) : 766 - 771
  • [38] Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models
    Varghese, Vicky
    Kumar, Gurunathan Saravana
    Krishnan, Venkatesh
    MEDICAL ENGINEERING & PHYSICS, 2017, 40 : 28 - 38
  • [39] Biomechanical effect of bone cement augmentation on rotational stability and pull-out strength of the Proximal Femur Nail Antirotation™
    Erhart, S.
    Schmoelz, W.
    Blauth, M.
    Lenich, A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1322 - 1327
  • [40] Does the anchorage form and depth influence the pull-out strength of screws from bone cement?An experimental study
    K. -D. Heller
    K. W. Zilkens
    J. Hammer
    B. Cohen
    Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 88 - 91