Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase– or monoamine oxidase–modified electrodes

被引:0
|
作者
Ceren Kaçar
Pınar Esra Erden
Berna Dalkiran
Emine Kübra İnal
Esma Kiliç
机构
[1] Ankara University,Department of Chemistry, Faculty of Science
[2] Ankara Hacı Bayram Veli University,Department of Chemistry, Polatlı Faculty of Science and Arts
来源
关键词
Amperometry; Biosensor; Biogenic amine; Indium tin oxide; Prussian blue; Screen-printed electrode;
D O I
暂无
中图分类号
学科分类号
摘要
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 × 10−6–6.9 × 10−4 M with a sensitivity of 1.84 μA mM−1. On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
引用
收藏
页码:1933 / 1946
页数:13
相关论文
共 50 条
  • [31] Disposable biosensors based on carbonaceous screen-printed electrodes and diamine oxidase
    Irina, Apetrei
    Veronica, Popa Claudia
    Constantin, Apetrei
    CURRENT OPINION IN BIOTECHNOLOGY, 2013, 24 : S65 - S65
  • [32] Determination of Antidepressants Using Monoamine Oxidase Amperometric Biosensors Based on Screen-Printed Graphite Electrodes Modified with Multi-Walled Carbon Nanotubes
    E. P. Medyantseva
    D. V. Brusnitsyn
    R. M. Varlamova
    M. A. Baibatarova
    G. K. Budnikov
    A. N. Fattakhova
    Pharmaceutical Chemistry Journal, 2014, 48 : 478 - 482
  • [33] Determination of Antidepressants Using Monoamine Oxidase Amperometric Biosensors Based on Screen-Printed Graphite Electrodes Modified with Multi-Walled Carbon Nanotubes
    Medyantseva, E. P.
    Brusnitsyn, D. V.
    Varlamova, R. M.
    Baibatarova, M. A.
    Budnikov, G. K.
    Fattakhova, A. N.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2014, 48 (07) : 478 - 482
  • [34] Prussian Blue onto platinum and optically transparent indium-tin oxide electrodes
    Totir, N
    Lete, C
    Lupu, S
    Ungureanu, EM
    Iftimie, N
    REVISTA DE CHIMIE, 2002, 53 (05): : 346 - 350
  • [35] Prussian Blue- and lactate oxidase-based amperometric biosensor for lactic acid
    Garjonyte, R
    Yigzaw, Y
    Meskys, R
    Malinauskas, A
    Gorton, L
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) : 33 - 38
  • [36] Performances of an electrochemical detector using Prussian blue modified indium tin oxide electrode
    Yi, In-Je
    Kim, Ju-Ho
    Choi, Y. J.
    Kang, C. J.
    Kim, Yong-Sang
    2006 1ST IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2006, : 1384 - +
  • [37] A novel electrochemical detector using Prussian blue modified indium tin oxide electrode
    Yi, IJ
    Kim, JH
    Kang, CJ
    Choi, YJ
    Lee, K
    Kim, YS
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (1B): : 438 - 441
  • [38] A novel electrochemical detector using prussian blue modified indium tin oxide electrode
    In-Je, Y.I.
    Kim, Ju-Ho
    Kang, C.J.
    Choi, Y.J.
    Lee, Kisay
    Kim, Yong-Sang
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (1 B): : 438 - 441
  • [39] Cholesterol biosensors based on cholesterol oxidase immobilized in a silica sol-gel matrix on a Prussian blue modified electrode
    Li, Jian-Ping
    Peng, Tu-Zhi
    Gaodeng Xuexiao Huaxue Xuebao/Chemical Journal of Chinese Universities, 2003, 24 (05):
  • [40] Cholesterol biosensors based on cholesterol oxidase immobilized in a silica sol-gel matrix on a Prussian Blue modified electrode
    Li, JP
    Peng, TZ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (05): : 798 - 802