Amperometric biogenic amine biosensors based on Prussian blue, indium tin oxide nanoparticles and diamine oxidase– or monoamine oxidase–modified electrodes

被引:0
|
作者
Ceren Kaçar
Pınar Esra Erden
Berna Dalkiran
Emine Kübra İnal
Esma Kiliç
机构
[1] Ankara University,Department of Chemistry, Faculty of Science
[2] Ankara Hacı Bayram Veli University,Department of Chemistry, Polatlı Faculty of Science and Arts
来源
关键词
Amperometry; Biosensor; Biogenic amine; Indium tin oxide; Prussian blue; Screen-printed electrode;
D O I
暂无
中图分类号
学科分类号
摘要
Biogenic amine biosensors, based on screen-printed carbon electrodes (SPCE) modified with Prussian blue (PB) and indium tin oxide nanoparticles (ITONP), are reported. PB/ITONP-modified SPCE was further modified with diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes to construct the biosensors. The morphology of the modified electrodes was studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and atomic force microscopy (AFM). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to enlighten the electrochemical properties of the modified electrodes at each step of biosensor fabrication. Electrode surface composition and experimental conditions were optimized and analytical performance characteristics of the biosensors were studied. Several biogenic amines were tested and both biosensors responded to histamine, putrescine and cadaverine. DAO/ITONP/PB/SPCE biosensor exhibited the highest response to histamine 6.0 × 10−6–6.9 × 10−4 M with a sensitivity of 1.84 μA mM−1. On the other hand, the highest sensitivity was obtained for cadaverine with the MAO/ITONP/PB/SPCE biosensor. The analytical utility of the presented biosensors were illustrated by the determination of cadaverine and histamine in cheese sample.
引用
收藏
页码:1933 / 1946
页数:13
相关论文
共 50 条
  • [21] Enzymeless Gabapentin Sensor Based on Prussian Blue-modified Indium Tin Oxide Electrodes for Sensing Gabapentin in Capsules
    Alshitari, Wael
    El-Said, Waleed A.
    CURRENT ANALYTICAL CHEMISTRY, 2024,
  • [22] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [23] Amperometric choline biosensors prepared by layer-by-layer deposition of choline oxidase on the Prussian blue-modified platinum electrode
    Shi, Haibin
    Yang, Yu
    Huang, Jiadong
    Zhao, Zixia
    Xu, Xinhua
    Anzai, Jun-ichi
    Osa, Tetsuo
    Chen, Qiang
    TALANTA, 2006, 70 (04) : 852 - 858
  • [24] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)
  • [25] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    Medyantseva, E. P.
    Brusnitsyn, D. V.
    Varlamova, R. M.
    Beshevets, M. A.
    Budnikov, H. C.
    Fattakhova, A. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 535 - 539
  • [26] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    E. P. Medyantseva
    D. V. Brusnitsyn
    R. M. Varlamova
    M. A. Beshevets
    H. C. Budnikov
    A. N. Fattakhova
    Journal of Analytical Chemistry, 2015, 70 : 535 - 539
  • [27] Single Printing Step Prussian Blue Bulk-Modified Transducers for Oxidase-Based Biosensors
    Vokhmyanina, Darya
    Daboss, Elena
    Sharapova, Olesya
    Mogilnikova, Mariia
    Karyakin, Arkady
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [28] Detection of histamine and other biogenic amines using biosensors based on amine oxidase
    Niculescu, M
    Nistor, C
    Ruzgas, T
    Frébort, I
    Sebela, M
    Pec, P
    Csöregi, E
    INFLAMMATION RESEARCH, 2001, 50 : S146 - S148
  • [29] Indium tin oxide electrodes for cell-based biosensors
    Mathine, DL
    Fang, DZ
    O'Connell, DJ
    Bahl, J
    Scholz, M
    Runyan, RB
    2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology, 2005, : 180 - 183
  • [30] Detection of histamine and other biogenic amines using biosensors based on amine oxidase
    M. Niculescu
    C. Nistor
    T. Ruzgas
    I. Frébort
    M. Šebela
    P. Peč
    El. Csöregi
    Inflammation Research, 2001, 50 (Suppl 2) : 146 - 148