Metal-on-Metal Hip Joint Prostheses: a Retrospective Case Series Investigating the Association of Systemic Toxicity with Serum Cobalt and Chromium Concentrations

被引:19
|
作者
Ho J.H. [1 ]
Leikin J.B. [2 ,3 ]
Dargan P.I. [1 ,4 ]
Archer J.R.H. [1 ,4 ]
Wood D.M. [1 ,4 ]
Brent J. [5 ]
机构
[1] Clinical Toxicology, Guy’s and St Thomas’ NHS Foundation Trust and King’s Health Partners, Westminster Bridge Road, London
[2] Medical Toxicology, Glenbrook Hospital, NorthShore University Health System—OMEGA, Glenview, IL
[3] Pritzker School of Medicine, University of Chicago, Chicago, IL
[4] Faculty of Life Sciences and Medicine, King’s College London, London
[5] School of Medicine, University of Colorado, Aurora, CO
关键词
Chromium; Cobalt; Metal-on-metal hip prosthesis; Toxicity;
D O I
10.1007/s13181-017-0629-1
中图分类号
学科分类号
摘要
Introduction: There have been concerns about prosthesis failure and the potential for systemic toxicity due to release of cobalt and chromium from metal-on-metal hip joint prostheses (MoM-HP). There is conflicting evidence on whether there is a correlation between higher cobalt and chromium concentrations and systemic toxicity. Methods: We undertook a retrospective review of consecutive patients with MoM-HP referred for outpatient review in toxicology clinics in London, UK, and in the USA recorded in the Toxicology Investigators Consortium (ToxIC) Registry from June 2011 to June 2015. Results: Thirty-one cases were identified; the median (IQR) serum cobalt concentration was 10.0 (3.8–32.8) mcg/L, and the median (IQR) serum chromium concentration was 6.9 (3.7–18.7) mcg/L. Twenty-three (74.2%) had symptoms, most commonly lethargy, hearing loss, and tinnitus. The odds ratios of symptomatic/asymptomatic patients for metal ion concentrations above/below 7 mcg/L were 1.87 (95% CI 0.37–9.57, p = 0.45) and 0.60 (95% CI 0.10–3.50, p = 0.57) for cobalt and chromium, respectively. Two (6.5%) patients with systemic cobalt toxicity had median (IQR) serum cobalt concentrations significantly higher than those without systemic features (630.4 [397.6–863.2] mcg/L versus 9.8 [2.9–16.4] mcg/L; p = 0.017). However, overall, there were no differences between cobalt (p = 0.38) or chromium (p = 0.92) concentrations between symptomatic and asymptomatic patients and no clinical features or investigation results correlated with cobalt or chromium concentration. Conclusion: Two (6.5%) of 31 individuals referred for assessment of MoM-HP were diagnosed with systemic cobalt toxicity. However, despite a high prevalence of reported symptoms, neither symptoms nor investigation results correlated with serum cobalt or chromium concentrations. © 2017, American College of Medical Toxicology.
引用
收藏
页码:321 / 328
页数:7
相关论文
共 50 条
  • [31] Case Report: High Chromium and Cobalt Levels in a Pregnant Patient with Bilateral Metal-on-Metal Hip Arthroplasties
    Fritzsche, Juliane
    Borisch, Cornelia
    Schaefer, Christof
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (08) : 2325 - 2331
  • [32] Neuropsychiatric symptoms following metal-on-metal implant failure with cobalt and chromium toxicity
    Ben Green
    Emily Griffiths
    Solomon Almond
    BMC Psychiatry, 17
  • [33] Neuropsychiatric symptoms following metal-on-metal implant failure with cobalt and chromium toxicity
    Green, Ben
    Griffiths, Emily
    Almond, Solomon
    BMC PSYCHIATRY, 2017, 17
  • [34] The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium - Reply
    Daniel, J.
    Ziaee, H.
    Pradhan, C.
    McMinn, D. J. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (11): : 1545 - 1546
  • [35] Cobalt chromium molybdenum metal combination for modular hip prostheses
    Schmidt, M
    Weber, H
    Schon, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) : S35 - S47
  • [36] Is the synovial fluid cobalt-to-chromium ratio related to the serum partitioning of metal debris following metal-on-metal hip arthroplasty?
    Langton, D. J.
    Natu, S.
    Harrington, C. F.
    Bowsher, J. G.
    Nargol, A. V. F.
    BONE & JOINT RESEARCH, 2019, 8 (03): : 146 - 155
  • [37] Cobalt and chromium concentrations in patients with metal on metal total hip replacements
    Jacobs, JJ
    Skipor, AK
    Doorn, PF
    Campbell, P
    Schmalzried, TP
    Black, J
    Amstutz, HC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (329) : S256 - S263
  • [38] Metal-on-metal bearings total hip arthroplasty: The cobalt and chromium ions release concern
    Delaunay, C.
    Petit, I.
    Learmonth, I. D.
    Oger, P.
    Vendittoli, P. A.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (08) : 894 - 904
  • [39] Metal-on-Metal Hip Prostheses and Systemic Health: A Cross-Sectional Association Study 8 Years after Implantation
    Prentice, Jennifer R.
    Clark, Matthew J.
    Hoggard, Nigel
    Morton, Allison C.
    Tooth, Claire
    Paley, Martyn N.
    Stockley, Ian
    Hadjivassiliou, Marios
    Wilkinson, J. Mark
    PLOS ONE, 2013, 8 (06):
  • [40] Do cobalt and chromium levels predict osteolysis in metal-on-metal total hip arthroplasty?
    Renner, Lisa
    Schmidt-Braekling, Tom
    Faschingbauer, Martin
    Boettner, Friedrich
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (12) : 1657 - 1662