The addition of contrast media such as BaSO4 or ZrO2 to bone cement has adverse effects in joint replacements, including third body wear and particle-induced bone resorption. Ground PMMA containing particles of the non-ionic water-soluble iodine-based X-ray contrast media, iohexol (IHX) and iodixanol (IDX), has, in bone tissue culture, shown less bone resorption than commercial cements. These water-soluble non-ceramic contrast media may change the mechanical properties of acrylic bone cement. The static mechanical properties of bone cement containing either IHX or IDX have been investigated. There was no significant difference in ultimate stress between Palacos R® (with 15.0 wt % of ZrO2) and plain cement with 8.0 wt % of IHX or IDX with mass median diameter (MMD) of 15.0 or 16.0 μm, while strain to failure was higher for the latter (p<0.02). The larger particles (15.0 or 16.0 μm) gave significantly higher (p<0.001) ultimate tensile strengths and strains to failure than smaller sizes (2.4 or 3.6 μm). Decreasing the amount of IHX from 10.0 wt % to 6.0 wt % gave a higher ultimate tensile strength (p<0.001) and strain to failure (p< 0.02). Scanning electron microscopy (SEM) showed the smaller contrast media particles attached to the surface of the polymer beads, which may prevent areas of the acrylate bead surface from participating in the polymerization. In conclusion, the mechanical properties of bone cement were influenced by the size and amount of contrast medium particles. By choosing the appropriate amount and size of particles of water-soluble non-ionic contrast media the mechanical properties of the new radio-opaque bone cement can be optimized, thus reaching and surpassing given regulatory standards.
引用
收藏
页码:889 / 894
页数:5
相关论文
共 50 条
  • [41] Ionic or non-ionic contrast media during coronary intervention: does it make a difference?
    Legrand, V
    EUROPEAN HEART JOURNAL, 2001, 22 (05) : 353 - 354
  • [42] A RANDOMIZED COMPARISON OF IONIC AND NON-IONIC CONTRAST-MEDIA IN COMPUTED CRANIAL TOMOGRAPHY
    LAMB, J
    NEURORADIOLOGY, 1984, 26 (02) : 157 - 157
  • [43] IONIC ANGIOGRAPHIC CONTRAST-MEDIA CAUSES SIGNIFICANTLY GREATER HISTAMINE-RELEASE THAN NON-IONIC CONTRAST-MEDIA
    SALEM, DN
    FINDLAY, SR
    ISNER, JM
    KONSTAM, MA
    CLINICAL RESEARCH, 1983, 31 (03): : A672 - A672
  • [44] IONIC ANGIOGRAPHIC CONTRAST-MEDIA CAUSES SIGNIFICANTLY GREATER HISTAMINE-RELEASE THAN NON-IONIC CONTRAST-MEDIA
    SALEM, DN
    FINDLAY, SR
    ISNER, JM
    KONSTAM, MA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (02) : 567 - 567
  • [45] WATER-SOLUBLE CONTRAST-MEDIA IN RADIOGRAPHY OF SMALL BOWEL OBSTRUCTION - COMPARISON OF IONIC AND NON-IONIC CONTRAST-MEDIA
    STORDAHL, A
    LAERUM, F
    GJOLBERG, T
    ENGE, I
    ACTA RADIOLOGICA, 1988, 29 (01) : 53 - 56
  • [46] EXTRA-VASCULAR LUNG WATER - EFFECTS OF IONIC AND NON-IONIC CONTRAST-MEDIA
    SLUTSKY, RA
    HACKNEY, DB
    PECK, WW
    HIGGINS, CB
    RADIOLOGY, 1983, 149 (02) : 375 - 378
  • [47] Effects of ionic and non-ionic paramagnetic contrast media on brain bio-electric activity
    Messori, A
    Polonara, G
    Regnicolo, L
    Provinciali, L
    Signorino, M
    Salvolini, U
    NEURORADIOLOGY, 2005, 47 (11) : 820 - 825
  • [48] EFFECTS OF IONIC AND NON-IONIC CONTRAST-MEDIA ON BLOOD-BRAIN-BARRIER INTEGRITY
    BURNS, EM
    DOBBEN, GD
    KRUCKEBERG, TW
    GAETANO, PK
    INVESTIGATIVE RADIOLOGY, 1980, 15 (05) : 395 - 395
  • [49] CLINICAL AND EXPERIMENTAL STUDIES ON THE IONIC AND NON-IONIC CONTRAST-MEDIA INTERACTIONS WITH ANTICOAGULANT DRUGS
    PARVEZ, Z
    MESSMORE, HL
    MONCADA, R
    ANDERSON, AC
    FAREED, J
    THROMBOSIS AND HAEMOSTASIS, 1981, 46 (01) : 361 - 361
  • [50] COMPARISON OF THE CARDIOVASCULAR-RESPONSES TO CAROTID INJECTIONS OF IONIC AND NON-IONIC CONTRAST-MEDIA
    MORRIS, TW
    FRANCIS, M
    FISCHER, HW
    INVESTIGATIVE RADIOLOGY, 1979, 14 (03) : 217 - 223