Tensile properties of a bone cement containing non-ionic contrast media

被引:0
|
作者
F. Kjellson
J.-S. Wang
T. Almén
A. Mattsson
J. Klaveness
K. E. Tanner
L. Lidgren
机构
[1] Lund University Hospital,Department of Orthopedics
[2] University Hospital MAS,Institute of Radiology and Physiology
[3] Bicema AB,School of Pharmacy
[4] ö,IRC in Biomedical Materials, Queen Mary
[5] University of Oslo,undefined
[6] University of London,undefined
关键词
PMMA; Ultimate Tensile Strength; Bone Cement; Iohexol; BaSO4;
D O I
暂无
中图分类号
学科分类号
摘要
The addition of contrast media such as BaSO4 or ZrO2 to bone cement has adverse effects in joint replacements, including third body wear and particle-induced bone resorption. Ground PMMA containing particles of the non-ionic water-soluble iodine-based X-ray contrast media, iohexol (IHX) and iodixanol (IDX), has, in bone tissue culture, shown less bone resorption than commercial cements. These water-soluble non-ceramic contrast media may change the mechanical properties of acrylic bone cement. The static mechanical properties of bone cement containing either IHX or IDX have been investigated. There was no significant difference in ultimate stress between Palacos R® (with 15.0 wt % of ZrO2) and plain cement with 8.0 wt % of IHX or IDX with mass median diameter (MMD) of 15.0 or 16.0 μm, while strain to failure was higher for the latter (p<0.02). The larger particles (15.0 or 16.0 μm) gave significantly higher (p<0.001) ultimate tensile strengths and strains to failure than smaller sizes (2.4 or 3.6 μm). Decreasing the amount of IHX from 10.0 wt % to 6.0 wt % gave a higher ultimate tensile strength (p<0.001) and strain to failure (p< 0.02). Scanning electron microscopy (SEM) showed the smaller contrast media particles attached to the surface of the polymer beads, which may prevent areas of the acrylate bead surface from participating in the polymerization. In conclusion, the mechanical properties of bone cement were influenced by the size and amount of contrast medium particles. By choosing the appropriate amount and size of particles of water-soluble non-ionic contrast media the mechanical properties of the new radio-opaque bone cement can be optimized, thus reaching and surpassing given regulatory standards.
引用
收藏
页码:889 / 894
页数:5
相关论文
共 50 条
  • [21] Non-ionic contrast media neurotoxicity mimicking intracerebral hematoma
    Bora Gürer
    Erdal Resit Yilmaz
    Ramazan Kahveci
    Zeki Sekerci
    Acta Neurochirurgica, 2011, 153 : 419 - 420
  • [22] Thrombogenic potential of non-ionic contrast media - Fact or fiction?
    Schrader, R
    EUROPEAN JOURNAL OF RADIOLOGY, 1996, 23 : S10 - S13
  • [23] BRAIN PARENCHYMA PENETRATION BY INTRATHECAL IONIC AND NON-IONIC CONTRAST-MEDIA
    SAGE, MR
    WILCOX, J
    EVILL, CA
    BENNESS, GT
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1982, 3 (05) : 481 - 483
  • [24] Influence of ionic and non-ionic radiographic contrast media on leukocyte adhesion molecules
    Vermeiren, GLJ
    Willems, R
    Claeys, MJ
    Vrints, C
    Slegers, H
    Jorens, PG
    MEDIATORS OF INFLAMMATION, 2003, 12 (05) : 269 - 275
  • [25] INTERACTIONS OF IONIC AND NON-IONIC INTRAVASCULAR CONTRAST-MEDIA WITH THROMBOLYTIC AGENTS
    MONCADA, R
    FAREED, J
    HOPPENSTEADT, D
    HUAN, XQ
    WALENGA, JM
    FASEB JOURNAL, 1988, 2 (04): : A392 - A392
  • [26] On the properties of agar gel containing ionic and non-ionic surfactants
    Prasad, K
    Siddhanta, AK
    Rakshit, AK
    Bhattacharya, A
    Ghosh, PK
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2005, 35 (3-4) : 135 - 144
  • [27] Frequency of late allergy-like adverse reactions following injection of intravascular non-ionic contrast media - A retrospective study comparing a non-ionic monomeric contrast medium with a non-ionic dimeric contrast medium
    Rydberg, J
    Charles, J
    Aspelin, P
    ACTA RADIOLOGICA, 1998, 39 (03) : 219 - 222
  • [28] PROPERTIES AND CHARACTERISTICS OF NON-IONIC IODINATED GRADIENT MEDIA
    RICKWOOD, D
    BIOLOGY OF THE CELL, 1982, 45 : 473 - 473
  • [29] NON-IONIC AND DIMERIC IONIC CONTRAST AGENTS
    GOUSSEMENT, A
    RADIOLOGY, 1983, 148 (01) : 318 - 319
  • [30] Myelography in the dog with non-ionic contrast media at different iodine concentrations
    Fatone, G
    Lamagna, F
    Pasolini, MP
    Potena, A
    Brunetti, A
    JOURNAL OF SMALL ANIMAL PRACTICE, 1997, 38 (07) : 292 - 294