Evaluation of objective and subjective binocular ocular refraction with looking in type

被引:0
|
作者
Fukushima, Megumi [1 ]
Hirota, Masakazu [2 ,3 ]
Yukimori, Takafumi [4 ]
Hayashi, Akio [4 ]
Hirohara, Yoko [4 ]
Saika, Makoto [4 ]
Matsuoka, Kumiko [2 ]
机构
[1] Teikyo Univ, Grad Sch Med Care & Technol, Div Orthopt, Itabashi Ku, Tokyo 1738605, Japan
[2] Teikyo Univ, Fac Med Technol, Dept Orthopt, 2-11-1 Kaga,Itabashi Ku, Tokyo 1738605, Japan
[3] Teikyo Univ, Sch Med, Dept Ophthalmol, Itabashi Ku, Tokyo, Japan
[4] Topcon Corp, Itabashi Ku, Tokyo, Japan
基金
日本学术振兴会;
关键词
Ocular refraction; Refractive error; Astigmatism; Autorefractometer; Visual acuity; RESOLUTION;
D O I
10.1186/s12886-024-03449-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background This study aimed to compare the results of the Chronos binocular/monocular refraction system, that measures objective and subjective ocular refraction in one unit, to objective findings obtained from a conventional autorefractometer and a conventional subjective ocular refraction using a trial-frame in real space.Methods Twenty-eight healthy volunteers (21.2 +/- 1.5 years old) were included in this study. Objective ocular refraction was measured using two tests: the Chronos binocular/monocular refraction system under binocular conditions and a conventional autorefractometer under monocular conditions. Subjective ocular refraction was measured using three tests: Chronos binocular/monocular refraction system under binocular, monocular conditions, and trial-frame in the real space under monocular conditions. The measurement distance was set to 5.0 m for each test. All ocular refractions were converted into spherical equivalents (SEs).Results The objective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (- 4.08 +/- 2.76 D) than with the conventional autorefractometer under monocular condition (- 3.85 +/- 2.66 D) (P = 0.002). Although, the subjective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (- 3.55 +/- 2.67 D) than with the trial-frame in the real space under monocular condition (- 3.33 +/- 2.75 D) (P = 0.002), Chronos binocular/monocular refraction system under monocular condition (- 3.17 +/- 2.57 D) was not significantly different from that in trial-frame in real space under monocular condition (P = 0.33).Conclusion These findings suggest that the Chronos binocular/monocular refraction system, which can complete both objective and subjective ocular refraction tests in a single unit, is suitable for screening ocular refraction, although it produces slightly more myopic results. Furthermore, subjective ocular refraction testing accuracy in Chronos binocular/monocular refraction system can be equivalent to trial-frame in real-space testing by switching from binocular to monocular condition.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Comparison of Subjective Ocular Refraction with Binocular Simultaneous Looking-in Type and Real Space
    Fukushima, Megumi
    Hirota, Masakazu
    Yukimori, Takafumi
    Hayashi, Akio
    Hirohara, Yoko
    Saika, Makoto
    Matsuoka, Kumiko
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [2] Subjective refraction - binocular alignment.
    Krause, Kunibert
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2010, 227 (07) : R93 - R106
  • [3] REPEATABILITY OF SUBJECTIVE AND OBJECTIVE REFRACTION
    ROSENFIELD, M
    CHIU, NN
    OPTOMETRY AND VISION SCIENCE, 1995, 72 (08) : 577 - 579
  • [4] Subjective refraction - binocular adjustment: action path
    von Livonius, Bettina
    AUGENHEILKUNDE UP2DATE, 2022, 12 (04) : 297 - 301
  • [5] Comparison Between Aberrometry-Based Binocular Refraction and Subjective Refraction
    Carracedo, Gonzalo
    Carpena-Torres, Carlos
    Serramito, Maria
    Batres-Valderas, Laura
    Gonzalez-Bergaz, Anahi
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (04):
  • [6] Assessment of objective and subjective eccentric refraction
    Lundstrom, L
    Gustafsson, J
    Unsbo, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U998 - U998
  • [7] Assessment of objective and subjective eccentric refraction
    Lundström, L
    Gustafsson, J
    Svensson, I
    Unsbo, P
    OPTOMETRY AND VISION SCIENCE, 2005, 82 (04) : 298 - 306
  • [8] EVALUATION OF OCULAR IRRITATION IN RABBIT - OBJECTIVE VERSUS SUBJECTIVE ASSESSMENT
    CONQUET, P
    DURAND, G
    LAILLIER, J
    PLAZONNET, B
    TOXICOLOGY AND APPLIED PHARMACOLOGY, 1977, 39 (01) : 129 - 139
  • [9] Clinical testing of a new objective binocular refraction device
    Shi, Lei
    Chen, Ying-Ling
    Lewis, James
    Wang, Ming
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [10] Binocular Objective Accommodation versus Subjective Measures
    Hammer, Maximilian
    Heggemann, Yvonne
    Auffarth, Gerd U.
    OPHTHALMOLOGY SCIENCE, 2023, 3 (04):