Evaluation of EUCAST rapid antimicrobial susceptibility testing (RAST) for positive blood cultures in clinical practice using a total lab automation

被引:0
|
作者
Jasmin Kaur Jasuja
Stefan Zimmermann
Irene Burckhardt
机构
[1] University Hospital Heidelberg,Department for Infectious Diseases
关键词
RAST; Time to report; Total lab automation (TLA) ; Blood culture; EUCAST;
D O I
暂无
中图分类号
学科分类号
摘要
Our objective was to evaluate EUCAST’s ‘rapid antimicrobial susceptibility testing’ (RAST) directly from positive blood culture that delivers antimicrobial results within 6 h for Staphylococcus aureus, Enterococcus spp., Escherichia coli, Klebsiella pneumoniae and Pseudomonas aeruginosa, using total lab automation. Zone diameters from RAST were compared with MIC results. Furthermore, its influence on time to report was investigated. RAST was performed to all positive aerobic and anaerobic blood culture bottles by subculturing them, i.e. onto Mueller-Hinton agar and adding six antibiotic discs covering Gram-negative and Gram-positive therapy (cefoxitin, ampicillin, vancomycin, piperacillin/tazobactam, meropenem and ciprofloxacin). RAST was automatically imaged after 6 h. Zone sizes were measured using a TLA software tool and interpreted according to EUCAST clinical breakpoints. Bacteria were identified using MALDI-TOF MS and MIC results were determined using Vitek2 panels. Categorial agreement between agar diffusion and MIC results was investigated. Additionally, time to RAST and time to Vitek were compared for 100 isolates (20 per species). Between November 2018 and April 2019, 3313 positive mono-bacterial blood culture bottles were collected of which 894 bottles with RAST-validated species were investigated. Among these bottles, 2029 individual antibiotic measurements were compared with MIC results from Vitek2 and 14 very major, 28 major and 12 minor errors were found. A median reduction of 17:30 h in time to report was observed. Introduction of RAST with automatic TLA imaging function could reduce time to report by 17:30 h. Excellent accordance between zone diameter and MIC results, particularly for cefoxitin, vancomycin and meropenem, was observed, but drawbacks due to ATU were seen.
引用
收藏
页码:1305 / 1313
页数:8
相关论文
共 50 条
  • [21] Impact of EUCAST Rapid Antimicrobial Susceptibility Testing (RAST) on optimal antimicrobial therapy in gram-negative bloodstream infections
    Top, Ozge Ozge
    Cifci, Beyza
    Buyukkoruk, Merve
    Can, Handan
    Yildiz, Pinar Aysert
    Martli, Halil Furkan
    Sahin, Elif Ayca
    Caglar, Kayhan
    Ozger, Hasan Selcuk
    INFECTIOUS DISEASES NOW, 2024, 54 (08):
  • [22] Evaluation of the Alfred AST® system for rapid antimicrobial susceptibility testing directly from positive blood cultures
    Sanchez-Carrillo, Carlos
    Pescador, Paula
    Ricote, Rosa
    Fuentes, Julia
    Losada, Carmen
    Candela, Ana
    Cercenado, Emilia
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2019, 38 (09) : 1665 - 1670
  • [23] Evaluation of the Alfred AST® system for rapid antimicrobial susceptibility testing directly from positive blood cultures
    Carlos Sánchez-Carrillo
    Paula Pescador
    Rosa Ricote
    Julia Fuentes
    Carmen Losada
    Ana Candela
    Emilia Cercenado
    European Journal of Clinical Microbiology & Infectious Diseases, 2019, 38 : 1665 - 1670
  • [24] EUCAST rapid antimicrobial susceptibility testing (RAST) compared to conventional susceptibility testing: implementation and potential added value in a tertiary hospital in Belgium
    Strubbe, Gregory
    Messiaen, Anne-Sophie
    Vandendriessche, Stien
    Verhasselt, Bruno
    Boelens, Jerina
    ACTA CLINICA BELGICA, 2023, 78 (05) : 385 - 391
  • [25] Implementation of the EUCAST rapid antimicrobial susceptibility test (RAST) directly from positive blood culture bottles without the advanced identification systems
    Taysi, Muhammet Ridvan
    Senturk, Gonul Cicek
    Caliskan, Elif
    Ocal, Duygu
    Miroglu, Gulsah
    Sencan, Irfan
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2022, 77 (04) : 1020 - 1026
  • [26] Evaluation of EUCAST Direct Rapid Antimicrobial Susceptibility Test Method in Blood Culture Bottles with Positive Signal
    Erdogan, Gizem
    Karakoc, Ayse Esra
    Yucel, Mihriban
    Yagci, Serap
    MIKROBIYOLOJI BULTENI, 2021, 55 (04): : 626 - 634
  • [27] Comment on "Impact of EUCAST rapid antimicrobial susceptibility testing (RAST) on management of Gram-negative bloodstream infection"
    Sajid, Samar
    INFECTIOUS DISEASES NOW, 2023, 53 (02):
  • [28] Evaluation of EUCAST rapid antimicrobial susceptibility test directly from positive blood culture for Pseudomonas aeruginosa
    Lebreton, Cedric
    Fournier, Damien
    Jeannot, Katy
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2024, 43 (10) : 2061 - 2064
  • [29] The EUCAST rapid disc diffusion method for antimicrobial susceptibility testing directly from positive blood culture bottles
    Jonasson, Emma
    Matuschek, Erika
    Kahlmeter, Gunnar
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2020, 75 (04) : 968 - 978
  • [30] Usage of 150 mm Mueller - Hinton Agar for the EUCAST rapid antimicrobial susceptibility test (RAST) directly from positive blood culture bottles
    Yildiz, Serap Suzuk
    Sahin, Sevgi
    Tavukcu, Esra
    Mumcuoglu, Ipek
    Hekimoglu, Can Huseyin
    Gureser, Ayse Semra
    Dal, Tuba
    ACTA MICROBIOLOGICA ET IMMUNOLOGICA HUNGARICA, 2025, 72 (01) : 43 - 48