Modulation Depth Discrimination by Cochlear Implant Users

被引:0
|
作者
Jessica J. M. Monaghan
Robert P. Carlyon
John M. Deeks
机构
[1] Macquarie University,Cambridge Hearing Group, Medical Research Council Cognition and Brain Sciences Unit
[2] National Acoustic Laboratories,undefined
[3] The Australian Hearing Hub,undefined
[4] University of Cambridge,undefined
关键词
Cochlear implant (CI); Modulation depth discrimination; Amplitude modulation sensitivity; Masking; Temporal processing; Temporal window; Envelope;
D O I
暂无
中图分类号
学科分类号
摘要
Cochlear implants (CIs) convey the amplitude envelope of speech by modulating high-rate pulse trains. However, not all of the envelope may be necessary to perceive amplitude modulations (AMs); the effective envelope depth may be limited by forward and backward masking from the envelope peaks. Three experiments used modulated pulse trains to measure which portions of the envelope can be effectively processed by CI users as a function of AM frequency. Experiment 1 used a three-interval forced-choice task to test the ability of CI users to discriminate less-modulated pulse trains from a fully modulated standard, without controlling for loudness. The stimuli in experiment 2 were identical, but a two-interval task was used in which participants were required to choose the less-modulated interval, ignoring loudness. Catch trials, in which judgements based on level or modulation depth would give opposing answers, were included. Experiment 3 employed novel stimuli whose modulation envelope could be modified below a variable point in the dynamic range, without changing the loudness of the stimulus. Overall, results showed that substantial portions of the envelope are not accurately encoded by CI users. In experiment 1, where loudness cues were available, participants on average were insensitive to changes in the bottom 30% of their dynamic range. In experiment 2, where loudness was controlled, participants appeared insensitive to changes in the bottom 50% of the dynamic range. In experiment 3, participants were insensitive to changes in the bottom 80% of the dynamic range. We discuss potential reasons for this insensitivity and implications for CI speech-processing strategies.
引用
收藏
页码:285 / 299
页数:14
相关论文
共 50 条
  • [41] Combining Place and Rate of Stimulation Improves Frequency Discrimination in Cochlear Implant Users
    Bissmeyer, Susan R. S.
    Goldsworthy, Raymond L.
    HEARING RESEARCH, 2022, 424
  • [42] Discrimination of Voice Pitch and Vocal-Tract Length in Cochlear Implant Users
    Gaudrain, Etienne
    Baskent, Deniz
    EAR AND HEARING, 2018, 39 (02): : 226 - 237
  • [43] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Stefano Cosentino
    Robert P. Carlyon
    John M. Deeks
    Wendy Parkinson
    Julie A. Bierer
    Journal of the Association for Research in Otolaryngology, 2016, 17 : 371 - 382
  • [44] Logatome Discrimination in Cochlear Implant Users: Subjective Tests Compared to the Mismatch Negativity
    Rahne, Torsten
    Ziese, Michael
    Rostalski, Dorothea
    Muehler, Roland
    THESCIENTIFICWORLDJOURNAL, 2010, 10 : 329 - 339
  • [45] The effect of simulated insertion depth differences on the vocal pitches of cochlear implant users
    Soleimanifar, Simin
    Staisloff, Hannah E.
    Aronoff, Justin M.
    JASA EXPRESS LETTERS, 2022, 2 (04):
  • [46] Modulation rate discrimination using half-wave rectified and sinusoidally amplitude modulated stimuli in cochlear-implant users
    Kreft, Heather A.
    Oxenham, Andrew J.
    Nelson, David A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2010, 127 (02): : 656 - 659
  • [47] Characterizing the relationship between modulation sensitivity and pitch resolution in cochlear implant users
    Camarena, Andres
    Goldsworthy, Raymond L.
    HEARING RESEARCH, 2024, 448
  • [48] Neural Modulation Transmission Is a Marker for Speech Perception in Noise in Cochlear Implant Users
    Gransier, Robin
    Luke, Robert
    van Wieringen, Astrid
    Wouters, Jan
    EAR AND HEARING, 2020, 41 (03): : 591 - 602
  • [49] Effects of stimulation rate on modulation detection and speech recognition by cochlear implant users
    Arora, Komal
    Vandali, Andrew
    Dowell, Richard
    Dawson, Pam
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2011, 50 (02) : 123 - 132
  • [50] Spectro-temporal cues enhance modulation sensitivity in cochlear implant users
    Zheng, Yi
    Escabi, Monty
    Litovsky, Ruth Y.
    HEARING RESEARCH, 2017, 351 : 45 - 54