Transcutaneous PCO2 monitoring in the evaluation of hyperventilation of patients with recurrent nerve paralysis

被引:0
|
作者
H. Miyazaki
H. Yamashita
T. Masuda
T. Yamamoto
S. Komiyama
机构
[1] Department of Otorhinolaryngology,
[2] Faculty of Medicine,undefined
[3] Kyushu University,undefined
[4] 3-1-1 Maidashi,undefined
[5] Higashiku,undefined
[6] Fukuoka 812–8582,undefined
[7] Japan,undefined
关键词
Key words Vocal disorder; Hyperventilation; Transcutaneus PCO2; Recurrent laryngeal nerve; paralysis;
D O I
暂无
中图分类号
学科分类号
摘要
Hyperventilation during phonation is one of the causes of fatigue in patients with vocal cord disorders. Transcutaneous (TC) PCO2 and PO2 were analyzed during phonation in patients with known recurrent nerve paralyses (RNP). There was no significant change in TCPCO2 in eight normal subjects. In cases with unilateral RNP and incomplete glottic closure, TCPCO2 decreased during phonation. This decrease in TCPCO2 resulted from hyperventilation during phonation. The TCPCO2 did not decrease in one case with RNP and complete glottic closure. In one case with incomplete glottic closure, the decrease in TCPCO2 and fatigue disappeared after treatment. These results suggest that hyperventilation is one of the causes for easy fatiguability during phonation in patients with RNP. Findings also show that measurements of TCPCO2 during phonation are useful for evaluating the cause of fatigue in patients with vocal disorders.
引用
收藏
页码:S47 / S50
相关论文
共 50 条
  • [31] NONINVASIVE CONTINUOUS FETAL TRANSCUTANEOUS PO2 AND PCO2 MONITORING DURING LABOR
    OKANE, M
    SHIGEMITSU, S
    INABA, J
    KORESAWA, M
    KUBO, T
    IWASAKI, H
    JOURNAL OF PERINATAL MEDICINE, 1989, 17 (06) : 399 - 410
  • [32] Noninvasive optical transcutaneous pCO2 gas sensor
    Kim, DE
    Lee, HJ
    Cha, EJ
    Kwon, DH
    Lee, SH
    Kang, SW
    SENSORS AND MATERIALS, 2005, 17 (05) : 249 - 257
  • [33] EFFECT OF CPAP ON TRANSCUTANEOUS PCO2 IN NORMAL HUMANS
    XIE, A
    RANKIN, F
    WONG, B
    BRADLEY, TD
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A680 - A680
  • [34] FETAL TRANSCUTANEOUS PCO2 MEASUREMENTS DURING LABOR
    BERGMANS, MGM
    VANGEIJN, HP
    WEBER, T
    NICKELSEN, C
    SCHMIDT, S
    VANDENBERG, PP
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1993, 51 (01) : 1 - 7
  • [35] Monitoring des pCO2 unter BeatmungMonitoring of pCO2 during ventilation
    F. S. Magnet
    W. Windisch
    J. H. Storre
    Medizinische Klinik - Intensivmedizin und Notfallmedizin, 2016, 111 : 202 - 207
  • [36] Transcutaneous monitoring as a replacement for arterial PCO2 monitoring during nocturnal non-invasive ventilation
    Storre, Jan Hendrik
    Magnet, Friederike Sophie
    Dreher, Michael
    Windisch, Wolfram
    RESPIRATORY MEDICINE, 2011, 105 (01) : 143 - 150
  • [37] NON-INVASIVE CONJUNCTIVAL PCO2 AND PO2 MONITORING DURING HYPERVENTILATION AND HYPOVENTILATION
    KRAM, HB
    APPEL, PL
    FINK, S
    SHOEMAKER, WC
    RESUSCITATION, 1988, 16 (04) : 263 - 269
  • [38] Clinical significance of transcutaneous PCO2 in patients with obstructive sleep apnea syndrome
    Sakaguchi, Tadashi
    Hataji, Osamu
    Saiki, Haruko
    Gabazza, Esteban C.
    D'Alessandro-Gabazz, Corina
    Nishii, Yoichi
    Kobayashi, Tetsu
    Taguchi, Osamu
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [39] The Accuracy of Transcutaneous PCO2 in Subjects With Severe Brain Injury: A Comparison With End-Tidal PCO2
    Rosier, Sebastien
    Launey, Yoann
    Bleichner, Jean-Paul
    Laviolle, Bruno
    Jouve, Alice
    Malledant, Yannick
    Seguin, Philippe
    RESPIRATORY CARE, 2014, 59 (08) : 1242 - 1247
  • [40] Skin blood flow influences the transcutaneous PCO2 (tc PCO2) during stress in the guinea pig
    Braems, GA
    Lang, U
    Kunzel, W
    JOURNAL OF PERINATAL MEDICINE, 1996, 24 (02) : 155 - 161