NEMA NU 2–2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes

被引:0
|
作者
Paulo R. R. V. Caribé
M. Koole
Yves D’Asseler
Timothy W. Deller
K. Van Laere
S. Vandenberghe
机构
[1] Ghent University,Medical Imaging and Signal Processing – MEDISIP
[2] UZ/KU Leuven,Division of Nuclear Medicine and Molecular Imaging
[3] GE Healthcare,undefined
来源
关键词
PET/MR; NEMA NU 2–2007; F; Ga; Y;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] NEMA NU 2-2007 performance characteristics of GE Signa integrated PET/MR for different PET isotopes
    Caribe, Paulo R. R. V.
    Koole, M.
    D'Asseler, Yves
    Deller, Timothy W.
    Van Laere, K.
    Vandenberghe, S.
    EJNMMI PHYSICS, 2019, 6 (1)
  • [2] NEMA NU 2-2007 Performance Characteristics of GE Signa Integrated PET/MR: Impact of Using Different PET Isotopes
    Caribe, P.
    Koole, M.
    Vandenberghe, S.
    Deller, T.
    van Laere, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S339 - S339
  • [3] GE Signa Integrated PET/MR: NEMA NU 2-2007 Performance Characteristics for 68Ga PET Imaging
    Caribe, P.
    Koole, M.
    Vandenberghe, S.
    Deller, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S507 - S508
  • [4] NEMA PET performance measurements of the GE SIGNA integrated TOF PET/MR
    Schramm, Georg
    Vunckx, Kathleen
    D'Hoe, Ester
    Vandenberghe, Stefaan
    Verhaeghe, Jeroen
    Van Laere, Koen
    Nuyts, Johan
    Koole, Michel
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [5] NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system
    Grant, Alexander M.
    Deller, Timothy W.
    Khalighi, Mohammad Mehdi
    Maramraju, Sri Harsha
    Delso, Gaspar
    Levin, Craig S.
    MEDICAL PHYSICS, 2016, 43 (05) : 2334 - 2343
  • [6] NEMA NU 2-2007 Measurements and GATE Monte Carlo Simulations of GE Signa integrated PET/MR for Pure and Non-Pure Positron Emitters
    Caribe, P. R. R. V.
    Koole, M.
    Diogo, A.
    D'Asseler, Y.
    Deller, T.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S352 - S353
  • [7] Monte Carlo Simulations of the GE Signa PET/MR for Different Radioisotopes
    Caribe, Paulo R. R. V.
    Vandenberghe, Stefaan
    Diogo, Andre
    Perez-Benito, David
    Efthimiou, Nikos
    Thyssen, Charlotte
    D'Asseler, Yves
    Koole, Michel
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [8] NEMA NU2-2001 performance results for the GE advance PET system
    Kohlmeyer, SG
    Stearns, CW
    Kinahan, PE
    Lewellen, TK
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 890 - 894
  • [9] NEMA NU2-2012 performance measurements of the United Imaging uPMR790: an integrated PET/MR system
    Chen, Shuguang
    Gu, Yushen
    Yu, Haojun
    Chen, Xin
    Cao, Tuoyu
    Hu, Lingzhi
    Shi, Hongcheng
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (06) : 1726 - 1735
  • [10] NEMA NU2-2012 performance measurements of the United Imaging uPMR790: an integrated PET/MR system
    Shuguang Chen
    Yushen Gu
    Haojun Yu
    Xin Chen
    Tuoyu Cao
    Lingzhi Hu
    Hongcheng Shi
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 1726 - 1735