Evaluation of the new LCx HIV RNA quantitative assay: comparison with the Cobas Amplicor HIV Monitor assay

被引:0
|
作者
Annemarie Berger
Holger F. Rabenau
Aribert Stief
Hugo Troonen
Hans W. Doerr
机构
[1] Institute for Medical Virology,
[2] Johann Wolfgang Goethe University Hospital,undefined
[3] Paul Ehrlich-Str. 40,undefined
[4] 60596 Frankfurt am Main,undefined
[5] Germany,undefined
[6] Abbott Diagnostika,undefined
[7] Wiesbaden Delkenheim,undefined
[8] Germany,undefined
来源
关键词
Quantitative Viral load HIV subtype LCx;
D O I
暂无
中图分类号
学科分类号
摘要
In the present study we evaluated the performance of the new LCx HIV RNA quantitative kit (Abbott Laboratories, Delkenheim, Germany) for the quantitative detection of HIV-1 RNA in human plasma in comparison to the Cobas Amplicor HIV-1 Monitor assay (Roche Diagnostics, Branchburg, N.J.), including samples containing a variety of HIV-1 subtypes. LCx and Cobas were compared using archived EDTA plasma samples collected from HIV-infected patients. Considering the lower limit of the linear range of 50 copies/ml, the detection rate of the LCx was 139 out of 174 (79.9%) versus 131 out of 174 (75.3%) of the Cobas. Overall agreement was 95.4% (166/174) at a cut-off of 50 copies. LCx and Cobas results on clinical samples were found linearly associated (r2=0.900) and strongly correlated (r=0.949). The mean viral load in the 174 frozen patient samples was 3.25 log10 copies/ml by LCx compared to 2.71 log10 copies/ml by Cobas. Considering only samples with a viral load ≥50 copies/ml, the average difference was –0.132 log copy/ml. Using a panel consisting of 9 plasma samples spiked with 9 different HIV-1 cultured isolates (A-H, and O) LCx detected the 9 subtypes with a high degree of precision, i.e., 9–33% coefficient of variation. As expected, the Cobas failed to detect the group O isolates. The results of the remaining samples showed a higher degree of variation (when testing four replicates of the subtype panel) than the LCx of 14.2–40.3%. Nevertheless, the results were comparable with the LCx data.
引用
收藏
页码:129 / 134
页数:5
相关论文
共 50 条
  • [1] Evaluation of the new LCx HIV RNA quantitative assay: comparison with the Cobas Amplicor HIV Monitor Assay
    Berger, A
    Rabenau, HF
    Steif, A
    Troonen, H
    Doerr, HW
    MEDICAL MICROBIOLOGY AND IMMUNOLOGY, 2001, 190 (03) : 129 - 134
  • [2] Validation of the COBAS AmpliPrep COBAS amplicor HIV-1 monitor assay
    Snyder, T. C.
    Hoefle, W. L.
    Kim, R. O.
    Miller, R. C.
    Roeven, R. T.
    Rehrauer, W. M.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2007, 9 (05): : 675 - 675
  • [3] Evaluation of the Cobas amplicor HCV monitor™ assay:: Comparison with the branched DNA assay
    Halfon, P
    Gerolami, V
    Khiri, H
    Bourlière, M
    Ouzan, D
    Halimi, G
    Cartouzou, G
    HEPATOLOGY, 1998, 28 (04) : 470A - 470A
  • [4] Evaluation of the Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor™ Ultrasensitive Test:: comparison with the Cobas Amplicor HIV-1 Monitor™ test (manual specimen preparation)
    Berger, A
    Scherzed, L
    Stürmer, M
    Preiser, W
    Doerr, HW
    Rabenau, HF
    JOURNAL OF CLINICAL VIROLOGY, 2002, 25 : S103 - S107
  • [5] Comparative evaluation of the Cobas Amplicor HIV-1 Monitor™ ultrasensitive test, the new Cobas AmpliPrep/Cobas Amplicor HIV-1 Monitor™ ultrasensitive test and the versant HIV RNA 3.0 assays for quantitation of HIV-1 RNA in plasma samples
    Berger, A
    Scherzed, L
    Sturmer, M
    Preiser, W
    Doerr, HW
    Rabenau, HF
    JOURNAL OF CLINICAL VIROLOGY, 2005, 33 (01) : 43 - 51
  • [6] Evaluation of the AMPLICOR CMV, COBAS AMPLICOR CMV monitor and antigenemia assay for cytomegalovirus disease
    Masaoka, T
    Hiraoka, A
    Ohta, K
    Tatsumi, N
    Watanabe, S
    Hotta, T
    Yabe, H
    Kato, S
    Aikawa, A
    Ohara, T
    Hasegawa, A
    Tanabe, K
    Toma, H
    Yasuoka, A
    Oka, S
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2001, 54 (01) : 12 - 16
  • [7] Comparison of three HIV1 RNA quantitation assays: NASBA HIV1 RNA QT, amplicor HIV monitor and quantiplex HIV RNA assay
    Revets, H
    Marrissens, D
    Dewit, S
    Clumeck, N
    Lauwers, S
    BIOLOGICALS, 1996, 24 (03) : 222 - 222
  • [8] Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays-LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5
    Katsoulidou, A
    Petrodaskalaki, M
    Sypsa, V
    Papachristou, E
    Anastassopoulou, CG
    Gargalianos, P
    Karafoulidou, A
    Lazanas, M
    Kordossis, T
    Andoniadou, A
    Hatzakis, A
    JOURNAL OF VIROLOGICAL METHODS, 2006, 131 (02) : 168 - 174
  • [9] Evaluation of a next-generation Vacutainer® tube for HIV viral load measurements with the Roche COBAS Amplicor HIV-1 Monitor® Assay
    Rainen, L.
    Belem, P.
    Wan, H.
    Dastane, A.
    Brown, M.
    Fernandes, H.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 645 - 645
  • [10] Evaluation of the Abbott LCx HIV-1 RNA quantitative, a new assay for quantitative determination of human immunodeficiency virus type 1 RNA
    Zanchetta, N
    Nardi, G
    Tocalli, L
    Drago, L
    Bossi, C
    Pulvirenti, FR
    Galli, C
    Gismondo, MR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (10) : 3882 - 3886