A novel iterative reconstruction algorithm allows reduced dose multidetector-row CT imaging of mechanical prosthetic heart valves

被引:0
|
作者
Jesse Habets
Petr Symersky
Bas A. J. M. de Mol
Willem P. Th. M. Mali
Tim Leiner
Ricardo P. J. Budde
机构
[1] University Medical Center Utrecht,Department of Radiology
[2] Academic Medical Center,Department of Cardiothoracic Surgery
关键词
Prosthetic heart valve; Computed tomography; Iterative reconstruction; Artifacts; Image noise; Reconstruction algorithm;
D O I
暂无
中图分类号
学科分类号
摘要
Multidetector-row CT is promising for prosthetic heart valve (PHV) assessment but retrospectively ECG-gated scanning has a considerable radiation dose. Recently introduced iterative reconstruction (IR) algorithms may enable radiation dose reduction with retained image quality. Furthermore, PHV image quality on the CT scan mainly depends on extent of PHV artifacts. IR may decrease streak artifacts. We compared image noise and artifact volumes in scans of mechanical PHVs reconstructed with conventional filtered back projection (FBP) to lower dose scans reconstructed with IR. Four different PHVs (St. Jude, Carbomedics, ON-X and Medtronic Hall) were scanned in a pulsatile in vitro model. Ten retrospectively ECG-gated CT scans were performed of each PHV at 120 kV, 600 mAs (high-dose CTDIvol 35.3 mGy) and 120 kV, 300 mAs (low-dose CTDIvol 17.7 mGy) on a 64 detector-row scanner. Diastolic and systolic images were reconstructed with FBP (high and low-dose) and the IR algorithm (low-dose only). Hypo- and hyperdense artifact volumes were determined using two threshold filters. Image noise was measured. Mean hypo- and hyperdense artifact volumes (mm3) were 1,235/5,346 (high-dose FBP); 2,405/6,877 (low-dose FBP) and 1,218/5,333 (low-dose IR). Low-dose IR reconstructions had similar image noise compared to high-dose FBP (16.5 ± 1.7 vs. 16.3 ± 1.6, mean ± SD, respectively, P = 1.0). IR allows ECG-gated PHV imaging with similar image noise and PHV artifacts at 50% less dose compared to conventional FBP in an pulsatile in vitro model.
引用
收藏
页码:1567 / 1575
页数:8
相关论文
共 43 条
  • [31] Iterative model reconstruction (IMR) algorithm for reduced radiation dose renal artery CT angiography with different tube voltage protocols
    Le Qin
    ZePeng Ma
    FuHua Yan
    WenJie Yang
    La radiologia medica, 2018, 123 : 83 - 90
  • [32] Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study
    Nakamoto, Atsushi
    Tanaka, Yoshikazu
    Juri, Hiroshi
    Nakai, Go
    Yoshikawa, Shushi
    Narumi, Yoshifumi
    EUROPEAN RADIOLOGY, 2017, 27 (07) : 2995 - 3003
  • [33] Deep learning reconstruction allows low-dose imaging while maintaining image quality: comparison of deep learning reconstruction and hybrid iterative reconstruction in contrast-enhanced abdominal CT
    Tamura, Akio
    Mukaida, Eisuke
    Ota, Yoshitaka
    Nakamura, Iku
    Arakita, Kazumasa
    Yoshioka, Kunihiro
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (05) : 2977 - 2984
  • [34] Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality
    Ippolito, Davide
    Fior, Davide
    Franzesi, Cammillo Talei
    Riva, Luca
    Casiraghi, Alessandra
    Sironi, Sandro
    RADIOLOGIA MEDICA, 2017, 122 (12): : 893 - 901
  • [35] Diagnostic accuracy of 256-row multidetector CT coronary angiography with prospective ECG-gating combined with fourth-generation iterative reconstruction algorithm in the assessment of coronary artery bypass: evaluation of dose reduction and image quality
    Davide Ippolito
    Davide Fior
    Cammillo Talei Franzesi
    Luca Riva
    Alessandra Casiraghi
    Sandro Sironi
    La radiologia medica, 2017, 122 : 893 - 901
  • [36] Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative Reconstruction Algorithm
    Solomon, Justin
    Marin, Daniele
    Choudhury, Kingshuk Roy
    Patel, Bhavik
    Samei, Ehsan
    RADIOLOGY, 2017, 284 (03) : 777 - 787
  • [37] Ultra-low-dose CT for left atrium and pulmonary veins imaging using new model-based iterative reconstruction algorithm
    Annoni, A. D.
    Andreini, D.
    Pontone, G.
    Formenti, A.
    Petulla, M.
    Consiglio, E.
    Nobili, E.
    Baggiano, A.
    Conte, E.
    Mushtaq, S.
    Bertella, E.
    Billi, F.
    Bartorelli, A. L.
    Montorsi, P.
    Pepi, M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (12) : 1366 - 1373
  • [38] Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm
    Nakaura, Takeshi
    Kidoh, Masafumi
    Sakaino, Naritsugu
    Utsunomiya, Daisuke
    Oda, Seitaro
    Kawahara, Tetsuya
    Harada, Kazunori
    Yamashita, Yasuyuki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04): : 913 - 923
  • [39] Low contrast- and low radiation dose protocol for cardiac CT of thin adults at 256-row CT: usefulness of low tube voltage scans and the hybrid iterative reconstruction algorithm
    Takeshi Nakaura
    Masafumi Kidoh
    Naritsugu Sakaino
    Daisuke Utsunomiya
    Seitaro Oda
    Tetsuya Kawahara
    Kazunori Harada
    Yasuyuki Yamashita
    The International Journal of Cardiovascular Imaging, 2013, 29 : 913 - 923
  • [40] Low Contrast Agent and Radiation Dose Protocol for Hepatic Dynamic CT of Thin Adults at 256-Detector Row CT: Effect of Low Tube Voltage and Hybrid Iterative Reconstruction Algorithm on Image Quality
    Nakaura, Takeshi
    Nakamura, Shinichi
    Maruyama, Natsuki
    Funama, Yoshinori
    Awai, Kazuo
    Harada, Kazunori
    Uemura, Shouzaburou
    Yamashita, Yasuyuki
    RADIOLOGY, 2012, 264 (02) : 445 - 454