Appropriate device selection for transcatheter atrial septal defect closure using three-dimensional transesophageal echocardiography

被引:0
|
作者
Hiroki Kitakata
Yuji Itabashi
Hideaki Kanazawa
Kotaro Miura
Mai Kimura
Keitaro Shinada
Marjolein C. de Jongh
Jin Endo
Hikaru Tsuruta
Mitsushige Murata
Akio Kawamura
Mitsuru Murata
Keiichi Fukuda
机构
[1] Keio University School of Medicine,Department of Cardiology
[2] Keio University School of Medicine,Department of Laboratory Medicine
[3] Haga Teaching Hospital,Department of Cardiology
[4] Tokai University Hachioji Hospital,Department of Laboratory Medicine
[5] International University of Health and Welfare,Department of Cardiovascular Medicine
关键词
Atrial septal defect; Transcatheter closure; Device size; Three-dimensional transesophageal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Detail morphological evaluation for ASD is essential to achieve successful transcatheter closure. Three-dimensional transesophageal echocardiography (3D-TEE) is emerging, but few studies have comprehensively verified the usefulness of 3D-TEE. We divided 329 patients who underwent transcatheter ASD closure at our university hospital into 157 in the Conventional group evaluated with 2-dimensional transesophageal echocardiography and balloon sizing (BS), and 172 in the 3D-TEE group evaluated with 3D-TEE additionally. We assessed usefulness of 3D-TEE and consider appropriate device selection procedure. Overall, the percentage with re-sizing of device tended to be lower in the 3D-TEE group than in the Conventional group (10.1% vs 6.0%, p = 0.187). Among preprocedural modalities, the device size was mainly decided based on the BS diameter. A logistic regression analysis demonstrated that large atrial septum aneurysms (ASA) were associated with a ≥ 2 mm discrepancy of the BS diameter from the preprocedural 3D-TEE diameter (p < 0.05). Compared to the Amplatzer Septal Occluder, the differences in device size and the preprocedural ASD measurement were greater when using the Occlutech Figulla Flex II Occluder (FFII). Particularly, among the patients implanted with FFIIs, the discrepancies of the device size from the 3D-TEE measurement were greater in patients with large ASA than those with small ASA. Preprocedural 3D-TEE is useful to select the appropriate device size. Particularly, it is necessary to select a much larger device than that derived from the preprocedural 3D-TEE measurement when using FFII in patients with a septal aneurysm.
引用
收藏
页码:1159 / 1168
页数:9
相关论文
共 50 条
  • [41] Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect
    Boccalandro, F
    Baptista, E
    Muench, A
    Carter, C
    Smalling, RW
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (04): : 437 - 440
  • [42] Clinical usefulness of real-time three dimensional transesophageal echocardiography during transcatheter closure of atrial septal defect in the catheterization laboratory
    Taniguchi, M.
    Okamoto, Y.
    Akagi, T.
    Otsuki, S.
    Kusano, K.
    Ito, H.
    Sano, S.
    EUROPEAN HEART JOURNAL, 2010, 31 : 595 - 595
  • [43] Real-Time Three-Dimensional Transesophageal Echocardiography in Patients with Secundum Atrial Septal Defects: Outcomes following Transcatheter Closure
    Johri, Amer M.
    Witzke, Christian
    Solis, Jorge
    Palacios, Igor F.
    Inglessis, Ignacio
    Picard, Michael H.
    Passeri, Jonathan J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (04) : 431 - 437
  • [44] Live/Real Time Three-Dimensional Transesophageal Echocardiography in Percutaneous Closure of Atrial Septal Defects
    Bhaya, Maneesha
    Mutluer, Ferit Onur
    Mahan, Edward
    Mahan, Luke
    Hsiung, Ming C.
    Yin, Wei-Hsian
    Wei, Jeng
    Tsai, Shen-Kou
    Zhao, Guang-Yu
    Yin, Wei-Hsian
    Pradhan, Manish
    Beniwal, Rajesh
    Joshi, Deepak
    Nabavizadeh, Fatemeh
    Singh, Amitoj
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2013, 30 (03): : 345 - 353
  • [45] Real-time Three-dimensional Transoesophageal Echocardiography for Guidance of Transcatheter Closure of a Complex Multifenestrated Atrial Septal Defect
    Nasis, Arthur
    Harper, Richard W.
    Mottram, Philip M.
    HEART LUNG AND CIRCULATION, 2011, 20 (05): : 343 - 344
  • [46] Two- and three-dimensional transesophageal echocardiography in patient selection and assessment of atrial septal defect closure by the new DAS-angel wings device - Initial clinical experience
    Magni, G
    Hijazi, ZM
    Pandian, NG
    Delabays, A
    Sugeng, L
    Laskari, C
    Marx, GR
    CIRCULATION, 1997, 96 (06) : 1722 - 1728
  • [47] Transesophageal echocardiographic monitoring for transcatheter closure of atrial septal defect
    Tseng, HC
    Hsiao, PN
    Lin, YH
    Wang, JK
    Tsai, SK
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2000, 99 (09) : 684 - 688
  • [48] Comparison of transthoracic and transesophageal three-dimensional echocardiography for assessment of atrial septal defect diameter in children
    Acar, P
    Dulac, Y
    Roux, D
    Rougé, P
    Duterque, D
    Aggoun, Y
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 91 (04): : 500 - +
  • [49] Transesophageal echocardiography-assisted transcatheter device closure of apical muscular ventricular septal defect
    Maddali, Madan M.
    Al-Maskari, Salim N.
    Kandachar, Pranav S.
    Arora, Nishant R.
    Lacour-Gayet, Francois
    SAUDI JOURNAL OF ANAESTHESIA, 2019, 13 (02) : 148 - +
  • [50] The role of three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects associated with aneurysm of the atrial septum
    Costa, Catia
    Anjos, Rui
    Martins, Duarte
    Canada, Manuel
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2017, 36 (03) : 225 - 226