Appropriate device selection for transcatheter atrial septal defect closure using three-dimensional transesophageal echocardiography

被引:0
|
作者
Hiroki Kitakata
Yuji Itabashi
Hideaki Kanazawa
Kotaro Miura
Mai Kimura
Keitaro Shinada
Marjolein C. de Jongh
Jin Endo
Hikaru Tsuruta
Mitsushige Murata
Akio Kawamura
Mitsuru Murata
Keiichi Fukuda
机构
[1] Keio University School of Medicine,Department of Cardiology
[2] Keio University School of Medicine,Department of Laboratory Medicine
[3] Haga Teaching Hospital,Department of Cardiology
[4] Tokai University Hachioji Hospital,Department of Laboratory Medicine
[5] International University of Health and Welfare,Department of Cardiovascular Medicine
关键词
Atrial septal defect; Transcatheter closure; Device size; Three-dimensional transesophageal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Detail morphological evaluation for ASD is essential to achieve successful transcatheter closure. Three-dimensional transesophageal echocardiography (3D-TEE) is emerging, but few studies have comprehensively verified the usefulness of 3D-TEE. We divided 329 patients who underwent transcatheter ASD closure at our university hospital into 157 in the Conventional group evaluated with 2-dimensional transesophageal echocardiography and balloon sizing (BS), and 172 in the 3D-TEE group evaluated with 3D-TEE additionally. We assessed usefulness of 3D-TEE and consider appropriate device selection procedure. Overall, the percentage with re-sizing of device tended to be lower in the 3D-TEE group than in the Conventional group (10.1% vs 6.0%, p = 0.187). Among preprocedural modalities, the device size was mainly decided based on the BS diameter. A logistic regression analysis demonstrated that large atrial septum aneurysms (ASA) were associated with a ≥ 2 mm discrepancy of the BS diameter from the preprocedural 3D-TEE diameter (p < 0.05). Compared to the Amplatzer Septal Occluder, the differences in device size and the preprocedural ASD measurement were greater when using the Occlutech Figulla Flex II Occluder (FFII). Particularly, among the patients implanted with FFIIs, the discrepancies of the device size from the 3D-TEE measurement were greater in patients with large ASA than those with small ASA. Preprocedural 3D-TEE is useful to select the appropriate device size. Particularly, it is necessary to select a much larger device than that derived from the preprocedural 3D-TEE measurement when using FFII in patients with a septal aneurysm.
引用
收藏
页码:1159 / 1168
页数:9
相关论文
共 50 条
  • [31] Percutaneous closure of second secundum atrial septal defect under guidance of three-dimensional transesophageal echocardiography guidance
    Demirkol, Sait
    Barcin, Cem
    Balta, Sevket
    Unlu, Murat
    ANADOLU KARDIYOLOJI DERGISI-THE ANATOLIAN JOURNAL OF CARDIOLOGY, 2013, 13 (04): : E22 - E23
  • [32] Clinical Implications of Real-Time Three-Dimensional Transesophageal Echocardiography for Catheter Closure of Atrial Septal Defect
    Kijima, Yasufumi
    Akagi, Teiji
    Nakagawa, Koji
    Taniguchi, Manabu
    Toh, Norihisa
    Kusano, Kengo
    Sano, Hiroshi Ito Shunji
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 99S - 99S
  • [33] Efficacy of three dimensional transesophageal echocardiography for percutaneous device closure of atrial septal defect without balloon sizing procedure
    Song, J. M.
    Jang, J. Y.
    Heo, R.
    Cho, M. S.
    Bae, J.
    Lee, S.
    Ahn, J. M.
    Park, D. W.
    Kim, D. H.
    Kang, D. H.
    Song, J. K.
    EUROPEAN HEART JOURNAL, 2016, 37 : 463 - 464
  • [34] Atrial septal defect closure device, a three-dimensional volume render
    Mitchell, G.
    Loo, B.
    Morgan-Hughes, G.
    HEART, 2010, 96 (15) : 1222 - 1222
  • [35] Clinical advantage of real-time three-dimensional transesophageal echocardiography for transcatheter closure of multiple atrial septal defects
    Manabu Taniguchi
    Teiji Akagi
    Yasufumi Kijima
    Shunji Sano
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1273 - 1280
  • [36] Clinical advantage of real-time three-dimensional transesophageal echocardiography for transcatheter closure of multiple atrial septal defects
    Taniguchi, Manabu
    Akagi, Teiji
    Kijima, Yasufumi
    Sano, Shunji
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1273 - 1280
  • [37] Three-Dimensional Transesophageal Echocardiography of Atrial Septal Defect: A Qualitative and Quantitative Anatomic Study
    Roberson, David A.
    Cui, Wei
    Patel, Dhaval
    Tsang, Wendy
    Sugeng, Lissa
    Weinert, Lynn
    Bharati, Saroja
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) : 600 - 610
  • [38] Three-Dimensional Transesophageal Echocardiographic Guidance during Retrieval of an Embolized Percutaneous Atrial Septal Defect Closure Device
    Lerakis, Stamatios
    Babaliaros, Vasilis
    Junahadhwalla, Zahid
    Williams, Stephen K.
    Martin, Randolph
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (08): : 970 - 972
  • [39] Optimising device imaging in atrial septal closure by three-dimensional transoesophageal echocardiography
    Budts, W.
    Troost, E.
    Voigt, J-U
    HEART, 2008, 94 (09) : 1110 - 1110
  • [40] A new method to select device size for atrial septal defect closure based on the largest defect diameter and area on real time three-dimensional transesophageal echocardiography
    Pedra, Carlos
    Arrieta, Raul
    Pedra, Simone
    Costa, Rodrigo
    Ribeiro, Marcelo
    Abizaid, Alexandre
    Fontes, Valmir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (18) : B211 - B211