Appropriate device selection for transcatheter atrial septal defect closure using three-dimensional transesophageal echocardiography

被引:0
|
作者
Hiroki Kitakata
Yuji Itabashi
Hideaki Kanazawa
Kotaro Miura
Mai Kimura
Keitaro Shinada
Marjolein C. de Jongh
Jin Endo
Hikaru Tsuruta
Mitsushige Murata
Akio Kawamura
Mitsuru Murata
Keiichi Fukuda
机构
[1] Keio University School of Medicine,Department of Cardiology
[2] Keio University School of Medicine,Department of Laboratory Medicine
[3] Haga Teaching Hospital,Department of Cardiology
[4] Tokai University Hachioji Hospital,Department of Laboratory Medicine
[5] International University of Health and Welfare,Department of Cardiovascular Medicine
关键词
Atrial septal defect; Transcatheter closure; Device size; Three-dimensional transesophageal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
Detail morphological evaluation for ASD is essential to achieve successful transcatheter closure. Three-dimensional transesophageal echocardiography (3D-TEE) is emerging, but few studies have comprehensively verified the usefulness of 3D-TEE. We divided 329 patients who underwent transcatheter ASD closure at our university hospital into 157 in the Conventional group evaluated with 2-dimensional transesophageal echocardiography and balloon sizing (BS), and 172 in the 3D-TEE group evaluated with 3D-TEE additionally. We assessed usefulness of 3D-TEE and consider appropriate device selection procedure. Overall, the percentage with re-sizing of device tended to be lower in the 3D-TEE group than in the Conventional group (10.1% vs 6.0%, p = 0.187). Among preprocedural modalities, the device size was mainly decided based on the BS diameter. A logistic regression analysis demonstrated that large atrial septum aneurysms (ASA) were associated with a ≥ 2 mm discrepancy of the BS diameter from the preprocedural 3D-TEE diameter (p < 0.05). Compared to the Amplatzer Septal Occluder, the differences in device size and the preprocedural ASD measurement were greater when using the Occlutech Figulla Flex II Occluder (FFII). Particularly, among the patients implanted with FFIIs, the discrepancies of the device size from the 3D-TEE measurement were greater in patients with large ASA than those with small ASA. Preprocedural 3D-TEE is useful to select the appropriate device size. Particularly, it is necessary to select a much larger device than that derived from the preprocedural 3D-TEE measurement when using FFII in patients with a septal aneurysm.
引用
收藏
页码:1159 / 1168
页数:9
相关论文
共 50 条
  • [1] Appropriate device selection for transcatheter atrial septal defect closure using three-dimensional transesophageal echocardiography
    Kitakata, Hiroki
    Itabashi, Yuji
    Kanazawa, Hideaki
    Miura, Kotaro
    Kimura, Mai
    Shinada, Keitaro
    de Jongh, Marjolein C.
    Endo, Jin
    Tsuruta, Hikaru
    Murata, Mitsushige
    Kawamura, Akio
    Murata, Mitsuru
    Fukuda, Keiichi
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04): : 1159 - 1168
  • [2] Three-dimensional Transesophageal Echocardiography of Atrial Septal Defect Device Closure
    Roberson, David A.
    Cui, Vivian Wei
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (02)
  • [3] Three-dimensional Transesophageal Echocardiography of Atrial Septal Defect Device Closure
    David A. Roberson
    Vivian Wei Cui
    Current Cardiology Reports, 2014, 16
  • [4] Percutaneous Closure of an Atrial Septal Defect Guided by Live Three-Dimensional Transesophageal Echocardiography
    Bhan, Amit
    Kapetanakis, Stamatis
    Pearson, Peter
    Dworakowski, Rafal
    Monaghan, M. J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (06) : 753.e1 - 753.e3
  • [5] PERCUTANEOUS CLOSURE OF SECOND ATRIAL SEPTAL DEFECT GUIDED BY THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Demirkol, S.
    Barcin, C.
    Balta, S.
    Unlu, M.
    Arslan, Z.
    Kucuk, U.
    Yokusoglu, M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S88 - S88
  • [6] Atrial natriuretic peptide and three-dimensional echocardiography after transcatheter closure of atrial septal defect
    Jingdong Ding
    Genshan Ma
    Yaoyao Huang
    Xiaoli Zhang
    Biao Liu
    Fengxiang Lu
    Cardiovascular Ultrasound, 6
  • [7] Atrial natriuretic peptide and three-dimensional echocardiography after transcatheter closure of atrial septal defect
    Ding, Jingdong
    Ma, Genshan
    Huang, Yaoyao
    Zhang, Xiaoli
    Liu, Biao
    Lu, Fengxiang
    CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)
  • [8] Role of three dimensional transesophageal echocardiography in transcatheter closure of atrial septal aneurysms
    Taha, Fatma Aboalsoud
    Elshedoudy, Sahar Abdallah
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0A) : A11 - A11
  • [9] Assessment of Atrial Septal Defect Anatomy by Real-Time Three-dimensional Transesophageal Echocardiography and Residual Shunting After Transcatheter Atrial Septal Defect Closure
    Johri, Amer M.
    Palacios, Igor F.
    Cubeddu, Roberto J.
    Inglessis, Ignacio
    Passeri, Jonathan
    CIRCULATION, 2009, 120 (18) : S392 - S392
  • [10] Three-dimensional echocardiography in transcatheter closure of atrial septal defects
    Acar, P
    CARDIOLOGY IN THE YOUNG, 2000, 10 (05) : 484 - 492