Digital radiography: are the manufacturers' settings too high? Optimisation of the Kodak digital radiography system with aid of the computed radiography dose index

被引:0
|
作者
Sinead E. Peters
Patrick C. Brennan
机构
[1] UCD School of Diagnostic Imaging,
[2] Herbert Avenue,undefined
[3] Dublin 4,undefined
[4] Ireland,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Radiography Digital radiation protection Thoracic radiography Image quality Exposure to patients;
D O I
暂无
中图分类号
学科分类号
摘要
Manufacturers offer exposure indices as a safeguard against overexposure in computed radiography, but the basis for recommended values is unclear. This study establishes an optimum exposure index to be used as a guideline for a specific CR system to minimise radiation exposures for computed mobile chest radiography, and compares this with manufacturer guidelines and current practice. An anthropomorphic phantom was employed to establish the minimum milliamperes consistent with acceptable image quality for mobile chest radiography images. This was found to be 2 mAs. Consecutively, 10 patients were exposed with this optimised milliampere value and 10 patients were exposed with the 3.2 mAs routinely used in the department of the study. Image quality was objectively assessed using anatomical criteria. Retrospective analyses of 717 exposure indices recorded over 2 months from mobile chest examinations were performed. The optimised milliampere value provided a significant reduction of the average exposure index from 1840 to 1570 (p<0.0001). This new "optimum" exposure index is substantially lower than manufacturer guidelines of 2000 and significantly lower than exposure indices from the retrospective study (1890). Retrospective data showed a significant increase in exposure indices if the examination was performed out of hours. The data provided by this study emphasise the need for clinicians and personnel to consider establishing their own optimum exposure indices for digital investigations rather than simply accepting manufacturers' guidelines. Such an approach, along with regular monitoring of indices, may result in a substantial reduction in patient exposure.
引用
收藏
页码:2381 / 2387
页数:6
相关论文
共 50 条
  • [21] ACR Dose Index Registry-Digital Radiography Pilot
    Don, Steven
    Sensakovic, William F.
    Gress, Dustin
    Zacharias-Andrews, Kay
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2021, 18 (08) : 1213 - 1215
  • [22] Options for radiation dose optimisation in pelvic digital radiography: A phantom study
    Manning-Stanley, Anthony S.
    Ward, Anthony J.
    England, Andrew
    RADIOGRAPHY, 2012, 18 (04) : 256 - 263
  • [23] Image quality and dose management in digital radiography: A new paradigm for optimisation
    Busch, HP
    Faulkner, K
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 143 - 147
  • [24] Does dose optimisation in digital panoramic radiography affect diagnostic performance?
    Luciano Augusto Cano Martins
    Danieli M. Brasil
    Laís A. Forner
    Cassiana Viccari
    Francisco Haiter-Neto
    Deborah Q. Freitas
    Matheus L. Oliveira
    Clinical Oral Investigations, 2021, 25 : 637 - 643
  • [25] Does dose optimisation in digital panoramic radiography affect diagnostic performance?
    Cano Martins, Luciano Augusto
    Brasil, Danieli M.
    Forner, Lais A.
    Viccari, Cassiana
    Haiter-Neto, Francisco
    Freitas, Deborah Q.
    Oliveira, Matheus L.
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (02) : 637 - 643
  • [26] Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system
    Sasaki Y.
    Abe K.
    Tabei M.
    Katsuragawa S.
    Kurosaki A.
    Matsuoka S.
    Radiological Physics and Technology, 2011, 4 (1) : 84 - 90
  • [27] A study of dose reduction using digital luminescence radiography for lateral skull radiography
    Seifert, H
    Kubale, R
    Hagen, T
    Kramann, B
    Leetz, HK
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (820): : 311 - 317
  • [28] Quality assurance of computed and digital radiography systems
    Walsh, C.
    Gorman, D.
    Byrne, P.
    Larkin, A.
    Dowling, A.
    Malone, J. F.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 271 - 275
  • [29] Digital mammography performed with computed radiography technology
    Jouan, B
    EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (01) : 18 - 24
  • [30] DIGITAL RADIOGRAPHY USING A COMPUTED TOMOGRAPHIC INSTRUMENT
    KATRAGADDA, CS
    FOGEL, SR
    COHEN, G
    WAGNER, LK
    MORGAN, C
    HANDEL, SF
    AMTEY, SR
    LESTER, RG
    RADIOLOGY, 1979, 133 (01) : 83 - 87