Field performance of a low-cost sensor in the monitoring of particulate matter in Santiago, Chile

被引:0
|
作者
Matías Tagle
Francisca Rojas
Felipe Reyes
Yeanice Vásquez
Fredrik Hallgren
Jenny Lindén
Dimitar Kolev
Ågot K. Watne
Pedro Oyola
机构
[1] Antonio Bellet 292,Centro Mario Molina Chile
[2] Aschebergsgatan 44,IVL Swedish Environmental Research Institute
[3] RISE Acreo,undefined
[4] Research Institutes of Sweden,undefined
[5] Environment Administration,undefined
[6] City of Gothenburg,undefined
来源
关键词
Citizen science; Reproducibility; Relative humidity; SDS011;
D O I
暂无
中图分类号
学科分类号
摘要
Integration of low-cost air quality sensors with the internet of things (IoT) has become a feasible approach towards the development of smart cities. Several studies have assessed the performance of low-cost air quality sensors by comparing their measurements with reference instruments. We examined the performance of a low-cost IoT particulate matter (PM10 and PM2.5) sensor in the urban environment of Santiago, Chile. The prototype was assembled from a PM10–PM2.5 sensor (SDS011), a temperature and relative humidity sensor (BME280) and an IoT board (ESP8266/Node MCU). Field tests were conducted at three regulatory monitoring stations during the 2018 austral winter and spring seasons. The sensors at each site were operated in parallel with continuous reference air quality monitors (BAM 1020 and TEOM 1400) and a filter-based sampler (Partisol 2000i). Variability between sensor units (n = 7) and the correlation between the sensor and reference instruments were examined. Moderate inter-unit variability was observed between sensors for PM2.5 (normalized root-mean-square error 9–24%) and PM10 (10–37%). The correlations between the 1-h average concentrations reported by the sensors and continuous monitors were higher for PM2.5 (R2 0.47–0.86) than PM10 (0.24–0.56). The correlations (R2) between the 24-h PM2.5 averages from the sensors and reference instruments were 0.63–0.87 for continuous monitoring and 0.69–0.93 for filter-based samplers. Correlation analysis revealed that sensors tended to overestimate PM concentrations in high relative humidity (RH > 75%) and underestimate when RH was below 50%. Overall, the prototype evaluated exhibited adequate performance and may be potentially suitable for monitoring daily PM2.5 averages after correcting for RH.
引用
收藏
相关论文
共 50 条
  • [41] Using Low-Cost Sensors for Measuring and Monitoring Particulate Matter with a Focus on Fine and Ultrafine Particles
    Kiresova, Simona
    Guzan, Milan
    Sobota, Branislav
    [J]. ATMOSPHERE, 2023, 14 (02)
  • [42] Assessment of Low-Cost Particulate Matter Sensor Systems against Optical and Gravimetric Methods in a Field Co-Location in Norway
    Vogt, Matthias
    Schneider, Philipp
    Castell, Nuria
    Hamer, Paul
    [J]. ATMOSPHERE, 2021, 12 (08)
  • [43] Evaluation and calibration of low-cost particulate matter sensors for respirable coal mine dust monitoring
    Feng Z.
    Zheng L.
    Zhang X.
    Liu J.
    Xue N.
    Wang M.
    [J]. Aerosol Science and Technology, 2024, 58 (02) : 158 - 169
  • [44] A Low-Cost Sensor Network for Monitoring Peatland
    Mitchell, Hazel Louise
    Cox, Simon J.
    Lewis, Hugh G.
    [J]. Sensors, 2024, 24 (18)
  • [45] A Low-Cost Optoacoustic Sensor for Environmental Monitoring
    Stylogiannis, Antonios
    Kousias, Nikolaos
    Kontses, Anastasios
    Ntziachristos, Leonidas
    Ntziachristos, Vasilis
    [J]. SENSORS, 2021, 21 (04) : 1 - 14
  • [46] A Study of the Dynamic Behaviour of Fine Particulate Matter in Santiago, Chile
    Salini, Giovanni A.
    Perez, Patricio
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (01) : 154 - 165
  • [47] Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
    Holstius, D. M.
    Pillarisetti, A.
    Smith, K. R.
    Seto, E.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (04) : 1121 - 1131
  • [48] Can data reliability of low-cost sensor devices for indoor air particulate matter monitoring be improved?-An approach using machine learning
    Chojer, H.
    Branco, P. T. B. S.
    Martins, F. G.
    Alvim-Ferraz, M. C. M.
    Sousa, S. I. V.
    [J]. ATMOSPHERIC ENVIRONMENT, 2022, 286
  • [49] Analyzing and Improving the Performance of a Particulate Matter Low Cost Air Quality Monitoring Device
    Bagkis, Evangelos
    Kassandros, Theodosios
    Karteris, Marinos
    Karteris, Apostolos
    Karatzas, Kostas
    [J]. ATMOSPHERE, 2021, 12 (02)
  • [50] Long-term field evaluation of the Plantower PMS low-cost particulate matter sensors
    Sayahi, T.
    Butterfield, A.
    Kelly, K. E.