Comparative one-month safety and effectiveness of five leading new-generation devices for transcatheter aortic valve implantation

被引:0
|
作者
Arturo Giordano
Nicola Corcione
Paolo Ferraro
Alberto Morello
Sirio Conte
Luca Testa
Francesco Bedogni
Alessandro Iadanza
Sergio Berti
Damiano Regazzoli
Enrico Romagnoli
Carlo Trani
Francesco Burzotta
Martino Pepe
Giacomo Frati
Giuseppe Biondi-Zoccai
机构
[1] Pineta Grande Hospital,Unita‘ Operativa di Interventistica Cardiovascolare
[2] Santa Lucia Hospital,Unità Operativa di Emodinamica
[3] IRCCS Policlinico San Donato,Department of Cardiology
[4] San Donato Milanese,Divisione di Emodinamica, Dipartimento di Scienze Cardiache
[5] Toraciche e Vascolari,Department of Biomedical Sciences
[6] Policlinico Santa Maria alle Scotte,Institute of Cardiology
[7] Fondazione C.N.R. G. Monasterio Ospedale del Cuore,Division of Cardiology, Department of Emergency and Organ Transplantation
[8] Humanitas University,Department of Medico
[9] Fondazione Policlinico Universitario A. Gemelli IRCCS,Surgical Sciences and Biotechnologies
[10] Università Cattolica del Sacro Cuore,undefined
[11] University of Bari,undefined
[12] Sapienza University of Rome,undefined
[13] IRCCS NEUROMED,undefined
[14] Mediterranea Cardiocentro,undefined
[15] University of Catania,undefined
[16] Spedali Civili di Brescia,undefined
[17] University of Pisa,undefined
[18] University of Turin,undefined
[19] Ospedale Niguarda Ca’ Granda,undefined
[20] Clinica Montevergine,undefined
[21] Centro Cardiologico Monzino,undefined
[22] Anthea Hospital GVM Care&Research,undefined
[23] Sapienza University of Rome-Policlinico Umberto I,undefined
[24] “SS Antonio e Biagio e Cesare Arrigo” Hospital,undefined
[25] Maria Pia Hospital,undefined
[26] San Giovanni di Dio e Ruggi d’Aragona,undefined
[27] Ospedale di Lecco,undefined
[28] Azienda Ospedaliera Universitaria di Parma,undefined
[29] Policlinico Universitario Mater Domini,undefined
[30] IRCCS San Martino,undefined
[31] Ospedale Bolognini,undefined
[32] Ospedale Civile di Legnano,undefined
[33] Ospedale S. Chiara,undefined
[34] Istituto Clinico San Rocco,undefined
[35] Fondazione Poliambulanza,undefined
[36] Maria Cecilia Hospital,undefined
[37] European Hospital,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Transcatheter aortic valve implantation (TAVI) for aortic stenosis is becoming an appealing alternative to surgical aortic valve replacement in high-risk patients and to medical therapy for inoperable ones. Several new-generation TAVI devices have been recently introduced, but comparative analyses are lacking. We aimed to compare 1-month outcomes associated with such five leading new-generation TAVI devices exploiting data collected in the prospective observational RISPEVA (Registro Italiano GISE sull’impianto di Valvola Aortica Percutanea) Study. We queried the dataset of the ongoing RISPEVA study to retrieve baseline, procedural and 1-month outcome details of patients undergoing TAVI with Acurate, Evolut, Portico, Lotus, and Sapien3. Analysis was based on unadjusted and propensity score-adjusted methods. We included 1976 patients, 234 (11.8%) treated with Acurate, 703 (35.6%) with Evolut, 151 (7.6%) with Lotus, 347 (17.6%) with Portico, and 541 (27.4%) with Sapien3. Unadjusted analysis for baseline features highlighted several significant differences, and other discrepancies were found for procedural features. Despite these differences, device and procedural success were similarly high (ranging from 98.0% to 99.4%, p > 0.05). However, procedural valve migration appeared more common with Acurate (p = 0.007), and major bleeding with Sapien3 (p = 0.002). Unadjusted analysis for 1-month outcomes also highlighted significant differences in the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure (favoring Portico, p < 0.001), major vascular complications (favoring Lotus, p < 0.001), renal failure (favoring Portico, p = 0.035), and permanent pacemaker implantation (favoring Acurate, p < 0.001). Propensity score-adjusted analyses showed lower rates of major adverse events with Evolut and Portico (p < 0.05), major vascular complications with Lotus and Portico (p < 0.05), renal failure with Sapien3 (p < 0.05) and permanent pacemaker implantation with Acurate (p < 0.05). In conclusion, new-generation TAVI devices have different profiles of early comparative safety and efficacy. These findings should be taken into account for individualized decision making and patient management.
引用
收藏
相关论文
共 50 条
  • [21] A New Generation Aortic Valve Device for Transcatheter Implantation
    Tzamtzis, S.
    Ghanbari, H.
    Seifalian, A.
    Burriesci, G.
    CARDIOLOGY, 2010, 115 (04) : 292 - 292
  • [22] Unplanned Hospital Readmissions After Transcatheter Aortic Valve Replacement in the Era of New-Generation Devices
    Faroux, Laurent
    Nombela-Franco, Luis
    Tetu-Couture, Maxime
    Romero Delgado, Teresa
    Mohammadi, Siamak
    Tirado-Conte, Gabriela
    Paradis, Jean-Michel
    Jimenez-Quevedo, Pilar
    Kalavrouziotis, Dimitri
    McInerney, Angela
    Delarochelliere, Robert
    Marroquin, Luis
    Dumont, Eric
    Alperi, Alberto
    Muntane-Carol, Guillem
    Macaya, Carlos
    Rodes-Cabau, Josep
    JOURNAL OF INVASIVE CARDIOLOGY, 2022, 34 (04): : E299 - E309
  • [23] Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis
    Barbanti, Marco
    Buccheri, Sergio
    Rodes-Cabau, Josep
    Gulino, Simona
    Genereux, Philippe
    Pilato, Gerlando
    Dvir, Danny
    Picci, Andrea
    Costa, Giuliano
    Tamburino, Corrado
    Leon, Martin B.
    Webb, John G.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 245 : 83 - 89
  • [24] Transcatheter Aortic Valve Implantation: Safety and Effectiveness of the Treatment of Degenerated Aortic Homograft
    Lopez-Otero, Diego
    Teles, Rui
    Gomez-Hospital, Joan A.
    Balestrini, Carlos S.
    Romaguera, Rafael
    Saaibi-Solano, Jose F.
    Neves, Jose
    Cid-Alvarez, Belen
    Brito, Joao
    Cequier-Fillat, Angel
    Trillo-Nouche, Ramiro
    REVISTA ESPANOLA DE CARDIOLOGIA, 2012, 65 (04): : 350 - 355
  • [25] Comparisons of different new-generation transcatheter aortic valve implantation devices for patients with severe aortic stenosis: a systematic review and network meta-analysis
    Yang, Yi-Xing
    Liu, Xin-Ming
    Fu, Yuan
    Li, Chuang
    Wang, Hong-Jiang
    Xu, Li
    Xia, Kun
    Zhang, Zhi-Yong
    Zhong, Jiu-Chang
    Chen, Mu-Lei
    Su, Pi-Xiong
    Wang, Le-Feng
    INTERNATIONAL JOURNAL OF SURGERY, 2023, 109 (08) : 2414 - 2426
  • [26] New-generation Myval transcatheter heart valve in severe aortic stenosis
    Akodad, Mariama
    Gall, Emmanuel
    LANCET, 2024, 403 (10445): : 2664 - 2665
  • [27] Effectiveness and Safety of Transcatheter Aortic Valve Implantation for Aortic Stenosis in Patients With "Porcelain" Aorta
    Ramirez-Del Val, Fernando
    Hirji, Sameer A.
    Yammine, Maroun
    Ejiofor, Julius I.
    McGurk, Siobhan
    Norman, Anthony
    Shekar, Prem
    Aranki, Sary
    Bhatt, Deepak L.
    Shah, Pinak
    Cohn, Lawrence H.
    Kaneko, Tsuyoshi
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 121 (01): : 62 - 68
  • [28] Network meta-analysis on the comparative effectiveness and safety of transcatheter aortic valve implantation with CoreValve or Sapien devices versus surgical replacement
    Biondi-Zoccai, G.
    Peruzzi, M.
    Abbate, A.
    Gertz, Z. M.
    Benedetto, U.
    Tonelli, E.
    D'Ascenzo, F.
    Giordano, A.
    Agostoni, P.
    Frati, G.
    HEART LUNG AND VESSELS, 2014, 6 (04) : 232 - 243
  • [29] Transcatheter Aortic Valve Replacement With Early and New Generation Devices
    Kim, Minsoo
    Yoon, Yong-Hoon
    Om, Sang Yong
    Park, Hanbit
    Cho, Sang-Cheol
    Park, Sangwoo
    Kim, Tae-Oh
    Lee, Sun Hack
    Kwon, Osung
    Lee, Kyusup
    Kang, Do-Yoon
    Ahn, Jung-Min
    Park, Duk-Woo
    Kang, Soo-Jin
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Park, Seung-Jung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (16) : S64 - S64
  • [30] Transcatheter Aortic Valve Replacement The Good Results of the New Generation of Transcatheter Aortic Valve Replacement Devices Are Confirmed
    Vahanian, Alec
    Himbert, Dominique
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04) : 385 - 386