Comparisons of different new-generation transcatheter aortic valve implantation devices for patients with severe aortic stenosis: a systematic review and network meta-analysis

被引:0
|
作者
Yang, Yi-Xing [1 ,2 ]
Liu, Xin-Ming [1 ,2 ]
Fu, Yuan [1 ,2 ]
Li, Chuang [1 ,2 ]
Wang, Hong-Jiang [1 ,2 ]
Xu, Li [1 ,2 ]
Xia, Kun [1 ,2 ]
Zhang, Zhi-Yong [1 ,2 ]
Zhong, Jiu-Chang [1 ,2 ]
Chen, Mu-Lei [1 ,2 ]
Su, Pi-Xiong [1 ,2 ,3 ,4 ]
Wang, Le-Feng [1 ,2 ,3 ,4 ]
机构
[1] Capital Med Univ, Beijing Chaoyang Hosp, Heart Ctr, Beijing, Peoples R China
[2] Capital Med Univ, Beijing Chaoyang Hosp, Beijing Key Lab Hypertens, Beijing, Peoples R China
[3] Capital Med Univ, Beijing Chaoyang Hosp, Heart Ctr, 8 Gongti South Rd, Beijing 100020, Peoples R China
[4] Capital Med Univ, Beijing Chaoyang Hosp, Beijing Key Lab Hypertens, 8 Gongti South Rd, Beijing 100020, Peoples R China
关键词
aortic stenosis; network meta-analysis; new-generation; systematic review; transcatheter aortic valve implantation; VENTRICULAR OUTFLOW TRACT; BALLOON-EXPANDABLE VALVES; PROCEDURAL OUTCOMES; CLINICAL-OUTCOMES; RISK PATIENTS; HEART-VALVES; REPLACEMENT; TAVI; MULTICENTER; PORTICO;
D O I
10.1097/JS9.0000000000000456
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background:Whether there are differences among the new-generation transcatheter aortic valve implantation (TAVI) devices for patients with aortic stenosis remains unclear. The aim of the study was to compare the efficiency and safety of different new-generation TAVI devices for patients with aortic stenosis. Materials and methods:A comprehensive search of PubMed, Embase and Web of Science from their inception to 1 February 2022. Randomized clinical trials and observational studies that compared two or more different TAVI devices were enroled. Pairwise meta-analysis and frequentist network meta-analysis were conducted to pool the outcome estimates of interest. Results:A total of 79 studies were finally included. According to the surface under the cumulative ranking, the top two ranked valves for lower rates of events were as follows: direct flow medical (DFM) (4.6%) and Lotus (48.8%) for lower rate of device success; Sapien 3 (16.8%) and DFM (19.7%) for lower mortality; DFM (8.6%) and Sapien 3 (25.5%) for lower rates of stroke; Evolut (27.6%) and DFM (35.8%) for lower rates of major and life-threatening bleeding; Portico (22.6%) and Sapien 3 (41.9%) for lower rates of acute kidney injury; Acurate (8.6%) and DFM (13.2%) for lower rates of permanent pacemaker implantation; Lotus (0.3%) and Sapien 3 (22.7%) for lower rates of paravalvular leak; Evolut (1.4%) and Portico (29.1%) for lower rates of mean aortic valve gradients. Conclusions:The findings of the present study suggested that the device success rates were comparable among these new-generation valves except for DFM. After excluding DFM, Sapien 3 might be the best effective for decreased mortality and stroke; Lotus might be the best effective for decreased paravalvular leak; Evolut might be the best effective for decreased major and life-threatening bleeding and mean aortic valve gradients; Acurate and Portico might be the best effective for decreased permanent pacemaker implantation and acute kidney injury, respectively.
引用
收藏
页码:2414 / 2426
页数:13
相关论文
共 50 条
  • [1] Transcatheter aortic valve replacement with new-generation devices: A systematic review and meta-analysis
    Barbanti, Marco
    Buccheri, Sergio
    Rodes-Cabau, Josep
    Gulino, Simona
    Genereux, Philippe
    Pilato, Gerlando
    Dvir, Danny
    Picci, Andrea
    Costa, Giuliano
    Tamburino, Corrado
    Leon, Martin B.
    Webb, John G.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 245 : 83 - 89
  • [2] Network meta-analysis of new-generation valves for transcatheter aortic valve implantation
    Takagi, Hisato
    Hari, Yosuke
    Nakashima, Kouki
    Kuno, Toshiki
    Ando, Tomo
    HEART AND VESSELS, 2019, 34 (12) : 1984 - 1992
  • [3] Network meta-analysis of new-generation valves for transcatheter aortic valve implantation
    Hisato Takagi
    Yosuke Hari
    Kouki Nakashima
    Toshiki Kuno
    Tomo Ando
    Heart and Vessels, 2019, 34 : 1984 - 1992
  • [4] Transcatheter aortic valve implantation versus surgical aortic valve replacement in patients with severe aortic stenosis: a systematic review and meta-analysis
    Swift, Stephanie Louise
    Puehler, Thomas
    Misso, Kate
    Lang, Shona Helen
    Forbes, Carol
    Kleijnen, Jos
    Danner, Marion
    Kuhn, Christian
    Haneya, Assad
    Seoudy, Hatim
    Cremer, Jochen
    Frey, Norbert
    Lutter, Georg
    Wolff, Robert
    Scheibler, Fueloep
    Wehkamp, Kai
    Frank, Derk
    BMJ OPEN, 2021, 11 (12):
  • [5] Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve With Aortic Stenosis: A Systematic Review and Meta-Analysis
    Chan, J. S. K.
    Harky, A.
    Singh, S.
    Eriksen, P.
    Tsui, L. H.
    Abdulsalam, A.
    Field, M.
    Nawaytou, O.
    BRITISH JOURNAL OF SURGERY, 2020, 107 : 34 - 34
  • [6] Systematic review and meta-analysis of transcatheter aortic valve implantation versus surgical aortic valve replacement for severe aortic stenosis
    Cao, Christopher
    Ang, Su C.
    Indraratna, Praveen
    Manganas, Con
    Bannon, Paul
    Black, Deborah
    Tian, David
    Yan, Tristan D.
    ANNALS OF CARDIOTHORACIC SURGERY, 2013, 2 (01) : 10 - 23
  • [7] Transcatheter Aortic Valve Implantation in Intermediate Surgical Risk Patients with Severe Aortic Stenosis: A Systematic Review and Meta-Analysis
    Singh, Kuljit
    Carson, Kristin
    Rashid, Mohammed K.
    Jayasinghe, Rohan
    AlQahtani, Abdulrahman
    Dick, Alexander
    Glover, Christopher
    Labinaz, Marino
    HEART LUNG AND CIRCULATION, 2018, 27 (02): : 227 - 234
  • [8] Transcatheter aortic valve replacement for bicuspid aortic valve stenosis with first- and new-generation bioprostheses: A systematic review and meta-analysis
    Ueshima, Daisuke
    Fovino, Luca Nai
    Brener, Sorin J.
    Fabris, Tommaso
    Scotti, Andrea
    Barioli, Alberto
    Giacoppo, Daniele
    Pavei, Andrea
    Fraccaro, Chiara
    Napodano, Massimo
    Tarantini, Giuseppe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 298 : 76 - 82
  • [9] Transcatheter aortic valve replacement for bicuspid aortic valve stenosis with first- and new-generation bioprostheses: a systematic review and meta-analysis
    Ueshima, D.
    Fovino, L. N. F. Nai
    Brener, S. J. B.
    Pavei, A. R.
    Fraccaro, C. F.
    Napodano, M. N.
    Tarantini, G. T.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1927 - 1927
  • [10] Transcatheter Aortic Valve Implantation (TAVI) in Patients With Bicuspid Aortic Valve Stenosis - Systematic Review and Meta-Analysis
    Phan, Kevin
    Wong, Sophia
    Phan, Steven
    Ha, Hakeem
    Qian, Pierre
    Yan, Tristan D.
    HEART LUNG AND CIRCULATION, 2015, 24 (07): : 649 - 659