Feasibility of tissue characterization of coronary plaques using 320-detector row computed tomography: comparison with integrated backscatter intravascular ultrasound

被引:0
|
作者
Shigekiyo Takahashi
Masanori Kawasaki
Shusaku Miyata
Keita Suzuki
Makoto Yamaura
Takahisa Ido
Takuma Aoyama
Hisayoshi Fujiwara
Shinya Minatoguchi
机构
[1] Gifu University Gradual School of Medicine,Department of Cardiology
[2] Kizawa Memorial Hospital,Department of Cardiology
来源
Heart and Vessels | 2016年 / 31卷
关键词
Coronary; Plaque; Tissue; Computed tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Recently, a new generation of multi-detector row computed tomography (CT) with 320-detector rows (DR) has become available in the clinical settings. The purpose of the present study was to determine the cutoff values of Hounsfield unit (HU) for discrimination of plaque components by comparing HU of coronary plaques with integrated backscatter intravascular ultrasound (IB-IVUS) serving as a gold standard. Seventy-seven coronary atherosclerotic lesions in 77 patients with angina were visualized by both 320-DR CT (Aquilion One, Toshiba, Japan) and IB-IVUS at the same site. To determine the thresholds for discrimination of plaque components, we compared HU with IB values as a gold standard. Optimal thresholds were determined from receiver operating characteristic (ROC) curves analysis. The HU values of lipid pool (n = 115), fibrosis (n = 93), vessel lumen and calcification (n = 73) were 28 ± 19 HU (range −18 to 69 HU), 98 ± 31 HU (44 to 195 HU), 357 ± 65 HU (227 to 534 HU) and 998 ± 236 HU (366 to 1,489 HU), respectively. The thresholds of 56 HU, 210 HU and 490 HU were the most reliable predictors of lipid pool, fibrosis, vessel lumen and calcification, respectively. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS (r = 0.63, p < 0.05), whereas fibrous volume measured by 320-DR CT was not. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS, whereas fibrous volume was not correlated with that measured by IB-IVUS because manual exclusion of the outside of vessel hindered rigorous discrimination between fibrosis and extravascular components.
引用
收藏
页码:29 / 37
页数:8
相关论文
共 50 条
  • [41] Comparison of multislice computed tomography with intravascular ultrasound for detection and characterization of coronary artery plaques: A systematic review
    Springer, Ivonne
    Dewey, Marc
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (02) : 275 - 282
  • [42] Tissue characteristics at the site of gradual progression of coronary plaques assessed by integrated backscatter intravascular ultrasound
    Kawasaki, Masanori
    Okubo, Munenori
    Ishihara, Yoshiyuki
    Mori, Urara
    Kubota, Tomoki
    Yasuda, Shinji
    Tanaka, Shinichiro
    Yamaki, Takahko
    Ojio, Shinsuke
    Tsuchiya, Kunihiko
    Nishigaki, Kazuhiko
    Takemura, Genzou
    Minatoguchi, Shinya
    Fujiwara, Hisayoshi
    CIRCULATION, 2006, 114 (18) : 398 - 398
  • [43] Assessment of coronary arteries in patients with atrial fibrillation by 320-detector computed tomography
    Imamura, T.
    Tanabe, K.
    Kishi, S.
    Taniwaki, M.
    Nakajima, H.
    Ibukuro, K.
    Aoki, J.
    Tanimoto, S.
    Otsuki, S.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2010, 31 : 141 - 141
  • [44] Using 320-detector row computed tomography angiography to investigate the arterial anatomy of the toe flaps on living humans
    Nguyen, Viet Tan
    Lam, Khanh
    Le, Van Doan
    SURGICAL AND RADIOLOGIC ANATOMY, 2021, 43 (10) : 1711 - 1719
  • [45] Using 320-detector row computed tomography angiography to investigate the arterial anatomy of the toe flaps on living humans
    Viet Tan Nguyen
    Khanh Lam
    Van Doan Le
    Surgical and Radiologic Anatomy, 2021, 43 : 1711 - 1719
  • [46] Volumetric 4D Computed Tomography with a 320-Detector Row Scanner for Radiotherapy Simulation
    Bracken, J.
    Driscoll, B.
    Jaffray, D.
    Coolens, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [47] Evaluation of coronary plaque type and composition on 320-row multidetector computed tomography: comparison to virtual histology intravascular ultrasound
    Van Velzen, J. E.
    Schuijf, J. D.
    De Graaf, F. R.
    Spano, F.
    Jukema, J. W.
    Schalij, M. J.
    Kroft, L. J.
    De Roos, A.
    Van der Wall, E. E.
    Bax, J. J.
    EUROPEAN HEART JOURNAL, 2010, 31 : 435 - 435
  • [48] Diagnosis of atresia of the main left coronary artery using 320-detector volumetric cardiac computed tomography
    Dhanoa, D.
    Jimenez-Juan, L.
    Ross, J. R.
    Crean, A. M.
    RADIOLOGIA, 2012, 54 (01): : 85 - 87
  • [49] Assessment of vulnerable plaques causing acute coronary syndrome using integrated backscatter intravascular ultrasound
    Sano, K
    Kawasaki, M
    Ishihara, Y
    Mao, M
    Tsuchlya, K
    Nishigaki, K
    Zhou, XR
    Minatoguchi, S
    Fujita, H
    Fujiwara, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 734 - 741
  • [50] Diagnostic Performance Of 320-Detector Row CT Coronary Angiography: a Comparison with Invasive Angiography
    Nasis, Arthur
    Leung, Michael C.
    Antonis, Paul R.
    Cameron, James D.
    Meredith, Ian T.
    Moir, William S.
    Hope, Sarah A.
    Troupis, John M.
    Crossett, Marcus P.
    Seneviratne, Sujith K.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 68D - 68D