Recently, a new generation of multi-detector row computed tomography (CT) with 320-detector rows (DR) has become available in the clinical settings. The purpose of the present study was to determine the cutoff values of Hounsfield unit (HU) for discrimination of plaque components by comparing HU of coronary plaques with integrated backscatter intravascular ultrasound (IB-IVUS) serving as a gold standard. Seventy-seven coronary atherosclerotic lesions in 77 patients with angina were visualized by both 320-DR CT (Aquilion One, Toshiba, Japan) and IB-IVUS at the same site. To determine the thresholds for discrimination of plaque components, we compared HU with IB values as a gold standard. Optimal thresholds were determined from receiver operating characteristic (ROC) curves analysis. The HU values of lipid pool (n = 115), fibrosis (n = 93), vessel lumen and calcification (n = 73) were 28 ± 19 HU (range −18 to 69 HU), 98 ± 31 HU (44 to 195 HU), 357 ± 65 HU (227 to 534 HU) and 998 ± 236 HU (366 to 1,489 HU), respectively. The thresholds of 56 HU, 210 HU and 490 HU were the most reliable predictors of lipid pool, fibrosis, vessel lumen and calcification, respectively. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS (r = 0.63, p < 0.05), whereas fibrous volume measured by 320-DR CT was not. Lipid volume measured by 320-DR CT was correlated with that measured by IB-IVUS, whereas fibrous volume was not correlated with that measured by IB-IVUS because manual exclusion of the outside of vessel hindered rigorous discrimination between fibrosis and extravascular components.
引用
收藏
页码:29 / 37
页数:8
相关论文
共 50 条
  • [31] Influential Factors on the Evaluation of Adamkiewicz Artery Using a 320-Detector Row Computed Tomography Device
    Amato, Alexandre C. M.
    Parga Filho, Jose R.
    Stolf, Noedir A. G.
    ANNALS OF VASCULAR SURGERY, 2017, 44 : 136 - 145
  • [32] Comparison of tissue characterization of coronary plaques between integrated backscatter intravascular ultrasound color-coded mapping method and angioscopy
    Kawasaki, M
    Takatsu, H
    Tsuchiya, K
    Nishigaki, K
    Minatoguchi, S
    Fujiwara, H
    CIRCULATION, 2000, 102 (18) : 410 - 410
  • [33] In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings
    Kawasaki, M
    Takatsu, H
    Noda, T
    Sano, K
    Ito, Y
    Hayakawa, K
    Tsuchiya, K
    Arai, M
    Nishigaki, K
    Takemura, G
    Minatoguchi, S
    Fujiwara, T
    Fujiwara, H
    CIRCULATION, 2002, 105 (21) : 2487 - 2492
  • [34] Comparisons of ultrasound radio frequency analysis between integrated backscatter intravascular ultrasound and virtual histology intravascular ultrasound for tissue characterization of coronary plaques
    Okubo, Munenori
    Kawasaki, Masanori
    Ishihara, Yoshiyuki
    Mori, Urara
    Kubota, Tomoki
    Yamaki, Takahiko
    Yasucla, Shinji
    Tanaka, Shinichiro
    Ojio, Shinsuke
    Tsuchiya, Kunihko
    Takemura, Genzou
    Nishigaki, Kazuhiko
    Salo, Masanao
    Takami, Tsuyoshi
    Minatoguchi, Shinya
    Fujiwara, Hisayoshi
    CIRCULATION, 2006, 114 (18) : 399 - 399
  • [35] Quantification and Characterization of Obstructive Coronary Plaques Using 64-Slice Computed Tomography: A Comparison With Intravascular Ultrasound
    Hur, Jin
    Kim, Young Jin
    Lee, Hye-Jeong
    Nam, Ji Eun
    Choe, Kyu Ok
    Seo, Jae Seung
    Choi, Dong-Hoon
    Kim, Jung-Sun
    Choi, Byoung Wook
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) : 186 - 192
  • [36] Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography
    Fuchs, Andreas
    Kuhl, J. Tobias
    Chen, Marcus Y.
    Helquist, Steffen
    Razeto, Marco
    Arakita, Kazumasa
    Steveson, Chloe
    Arai, Andrew E.
    Kofoed, Klaus F.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (05) : 393 - 398
  • [37] Tissue characterization of in-stent neointima using integrated backscatter intravascular ultrasound; Comparison with optical coherence tomography
    Sato, K.
    Takebayashi, H.
    Goto, K.
    Kodama, S.
    Taniguchi, M.
    Kikuta, Y.
    Fujiwara, Y.
    Hiramatsu, S.
    Haruta, S.
    EUROPEAN HEART JOURNAL, 2011, 32 : 832 - 833
  • [38] Development and feasibility of three dimensional integrated backscatter intravascular ultrasound for volumetric analysis of coronary plaques
    Kawasaki, M
    Okulbo, M
    Sano, K
    CIRCULATION, 2005, 112 (17) : U832 - U833
  • [39] Diagnosis and Treatment of Intracranial Aneurysms with 320-Detector Row Volumetric Computed Tomography Angiography
    Chen, Wenhua
    Xing, Wei
    Peng, Ya
    He, Zhongming
    Wang, Caoye
    Wang, Qi
    WORLD NEUROSURGERY, 2016, 91 : 347 - 356
  • [40] 320-detector row cardiac computed tomography in the diagnosis of arrhythmogenic right ventricular cardiomyopathy
    Nasis, Arthur
    Antonis, Paul R.
    Seneviratne, Sujith K.
    EUROPACE, 2009, 11 (08): : 1125 - 1126