Computer-aided detection in direct digital full-field mammography: initial results

被引:0
|
作者
F. Baum
U. Fischer
S. Obenauer
E. Grabbe
机构
[1] Department of Radiology,
[2] Georg-August-Universität Göttingen,undefined
[3] Robert-Koch-Strasse 40,undefined
[4] 37075 Göttingen,undefined
[5] Germany,undefined
来源
European Radiology | 2002年 / 12卷
关键词
Computer-aided diagnosis Direct digital full-field mammography Microcalcifications BI-RADS classification;
D O I
暂无
中图分类号
学科分类号
摘要
For the first time, full-field digital mammography (FFDM) allows computer-aided detection (CAD) analysis of directly acquired digital image data. The purpose of this study was to evaluate a CAD system in patients with histologically correlated breast cancer depicted with FFDM. Sixty-three cases of histologically proven breast cancer detected with FFDM (Senographe 2000D, GE Medical Systems, Buc, France) were analyzed using a CAD system (Image Checker V2.3, R2 Technology, Los Altos, Calif.). Fourteen of these malignancies were characterized as microcalcifications, 37 as masses, and 12 as both. The mammographic findings were categorized as BI-RADS 3 (n=5), BI-RADS 4 (n=17) and BI-RADS 5 (n=40). The sensitivity for malignant lesions and the rate of false-positive marks per image were calculated. The sensitivity and its 95% confidence interval (CI) were estimated. The sensitivity of the CAD R2 system in breast cancer seen on FFDM was 89% for microcalcifications [CI95%=(70%; 98%)] and 81% for masses [CI95%=(67%; 91%)]. As expected, the detection rate was higher in lesions categorized as BI-RADS 5 (37 of 40) compared with lesions categorized as BI-RADS 4 (11 of 17). In the group categorized as BI-RADS 3 the detection rate was 4 of 5 lesions; however, this group was very small. The rate of false-positive marks was 0.35 microcalcification marks/image and 0.26 mass marks/image. The overall rate of false-positive marks was 0.61 per image. CAD based on FFDM provides an optimized work flow. Results are equivalent to the results reported for CAD analysis of secondarily digitized image data. Sensitivity for microcalcifications is acceptable and for masses is low. The number of false-positive marks per image should be reduced.
引用
收藏
页码:3015 / 3017
页数:2
相关论文
共 50 条
  • [31] Microcalcification detection in full-field digital mammograms: A fully automated computer-aided system
    Basile, T. M. A.
    Fanizzi, A.
    Losurdo, L.
    Bellotti, R.
    Bottigli, U.
    Dentamaro, R.
    Didonna, V
    Fausto, A.
    Massafra, R.
    Moschetta, M.
    Tamborra, P.
    Tangaro, S.
    La Forgia, D.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 1 - 9
  • [32] Sensitivity of integral computer-aided detection with full-field digital mammography for detection of breast cancer according to different histopathological tumor types and appearances
    K Pinker
    N Perry
    S Milner
    K Mokbel
    S Duffy
    [J]. Breast Cancer Research, 12
  • [33] Sensitivity of integral computer-aided detection with full-field digital mammography for detection of breast cancer according to different histopathological tumor types and appearances
    Pinker, K.
    Perry, N.
    Milner, S.
    Mokbel, K.
    Duffy, S.
    [J]. BREAST CANCER RESEARCH, 2010, 12
  • [34] Computer-aided detection of breast masses depicted on full-field digital mammograms: a performance assessment
    Zheng, B.
    Sumkin, J. H.
    Zuley, M. L.
    Lederman, D.
    Wang, X.
    Gur, D.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014): : E153 - E161
  • [35] Computer-Aided Detection Systems for Digital Mammography
    Perez-Diaz, Marlen
    Orozco-Morales, Ruben
    Suarez-Aday, Eduardo
    Pirchio, Rosana
    [J]. VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 265 - 271
  • [36] Initial clinical experience with full-field digital mammography
    Moore, RH
    Kopans, DB
    Niklason, LT
    Slanetz, PJ
    McCarthy, KA
    Hall, DA
    [J]. RADIOLOGY, 1997, 205 : 570 - 570
  • [37] Sensitivity of integral computer-aided detection (CAD) with full-field digital mammography (FFDM) for detection of breast cancer according to different histopathological types and appearance
    Pinker, K.
    Milner, S.
    Stephen, D.
    Mokbel, K.
    Perry, N. M.
    [J]. EJC SUPPLEMENTS, 2010, 8 (03): : 227 - 227
  • [38] VinDr-Mammo: A large-scale benchmark dataset for computer-aided diagnosis in full-field digital mammography
    Hieu T. Nguyen
    Ha Q. Nguyen
    Hieu H. Pham
    Khanh Lam
    Linh T. Le
    Minh Dao
    Van Vu
    [J]. Scientific Data, 10
  • [39] VinDr-Mammo: A large-scale benchmark dataset for computer-aided diagnosis in full-field digital mammography
    Nguyen, Hieu T. T.
    Nguyen, Ha Q. Q.
    Pham, Hieu H. H.
    Lam, Khanh
    Le, Linh T. T.
    Dao, Minh
    Vu, Van
    [J]. SCIENTIFIC DATA, 2023, 10 (01)
  • [40] Computer-aided detection (CAD) on 90 biopsy-proven breast cancer cases acquired on a full-field digital mammography (FFDM) system
    O'Shaughnessy, KF
    Castellino, RA
    Muller, SL
    Benali, K
    [J]. RADIOLOGY, 2001, 221 : 471 - 471