Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph

被引:0
|
作者
I. I. Rod’ko
G. A. Sarychev
P. V. Balakirev
T. V. Bondarenko
I. L. Dergacheva
A. S. Evteev
S. N. Kovalev
S. A. Koloskov
T. A. Krylova
T. K. Lobzhanidze
S. A. Polikhov
V. P. Smirnov
G. B. Sharkov
G. E. Gorlachev
I. V. Gulidov
S. A. Ivanov
A. D. Kaprin
Yu. S. Romanko
E. V. Khmelevskii
L. Yu. Ovchinnikova
V. I. Shvedunov
N. V. Shvedunov
D. V. Cherednichenko
机构
[1] National Research Nuclear University MEPhI (Moscow Engineering Physics Institute),Laboratory of Electron Accelerators (LEU MGU)
[2] Research Institute of Technical Physics and Automation (NIITFA),undefined
[3] Radiation-Oncological Intelligent Systems and Services,undefined
[4] National Medical Research Center of Radiology (NMITS Radiology),undefined
[5] Lomonosov Moscow State University,undefined
[6] Rusatom Healthcare,undefined
来源
Atomic Energy | 2019年 / 125卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
A system currently under development for remote radiotherapy based on a 6 MeV linac and cone-beam computer tomograph is presented. Its distinguishing design features and solutions are described: compact 5-cm wavelength electron accelerator, solid-state modulator, visualization in the bremsstrahlung beam with low nominal energy 2.5 MeV, bremsstrahlung beam without a compensating filter, cone-beam computer tomography, multi-leaf collimator, adaptive radiotherapy, and a therapeutic table with six degrees of freedom. The system is compared with foreign analogs.
引用
收藏
页码:333 / 337
页数:4
相关论文
共 50 条
  • [1] DEVELOPMENT OF A RADIOTHERAPY SYSTEM BASED ON 6 MeV LINAC AND CONE-BEAM COMPUTER TOMOGRAPH
    Rod'ko, I. I.
    Sarychev, G. A.
    Balakirev, P., V
    Bondarenko, T., V
    Dergacheva, I. L.
    Evteev, A. S.
    Kovalev, S. N.
    Koloskov, S. A.
    Krylova, T. A.
    Lobzhanidze, T. K.
    Polikhov, S. A.
    Smirnov, V. P.
    Sharkov, G. B.
    Gorlachev, G. E.
    Gulidov, I., V
    Ivanov, S. A.
    Kaprin, A. D.
    Romanko, Yu S.
    Khmelevskii, E., V
    Ovchinnikova, L. Yu
    Shvedunov, V., I
    Shvedunov, N., V
    Cherednichenko, D., V
    ATOMIC ENERGY, 2019, 125 (05) : 333 - 337
  • [2] Correction to: Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph
    I. I. Rod’ko
    G. A. Sarychev
    P. V. Balakirev
    T. V. Bondarenko
    I. L. Dergacheva
    A. S. Evteev
    S. N. Kovalev
    S. A. Koloskov
    T. A. Krylova
    T. K. Lobzhanidze
    S. A. Polikhov
    V. P. Smirnov
    G. B. Sharkov
    G. E. Gorlachev
    I. A. Gulidov
    S. A. Ivanov
    A. D. Kaprin
    Yu. S. Romanko
    E. V. Khmelevskii
    L. Yu. Ovchinnikova
    V. I. Shvedunov
    N. V. Shvedunov
    D. V. Cherednichenko
    Atomic Energy, 2019, 126 : 342 - 342
  • [3] Development of a Radiotherapy System Based on 6 MeV Linac and Cone-Beam Computer Tomograph (vol 125, pg 333, 2019)
    Rod'ko, I. I.
    Sarychev, G. A.
    Balakirev, P. V.
    Bondarenko, T. V.
    Dergacheva, I. L.
    Evteev, A. S.
    Kovalev, S. N.
    Koloskov, S. A.
    Krylova, T. A.
    Lobzhanidze, T. K.
    Polikhov, S. A.
    Smirnov, V. P.
    Sharkov, G. B.
    Gorlachev, G. E.
    Gulidov, I. A.
    Ivanov, S. A.
    Kaprin, A. D.
    Romanko, Yu S.
    Khmelevskii, E. V.
    Ovchinnikova, L. Yu
    Shvedunov, V. I.
    Shvedunov, N. V.
    Cherednichenko, D. V.
    ATOMIC ENERGY, 2019, 126 (05) : 342 - 342
  • [4] Cone-beam CT for radiotherapy applications
    Cho, P.S.
    Johnson, R.H.
    Griffin, T.W.
    1863, Institute of Physics Publishing Ltd, Bristol, Engl (40):
  • [5] CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS
    CHO, PS
    JOHNSON, RH
    GRIFFIN, TW
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11): : 1863 - 1883
  • [6] Linac cone-beam CT option for treatment planning: A possible approach for DART (dynamic adaptive radiotherapy)?
    Cossmann, P. H.
    Stuessi, A.
    von Briel, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S700 - S701
  • [7] Application of asymmetric cone-beam CT in radiotherapy
    Yu, LF
    Pelizzari, C
    Pan, XC
    Riem, H
    Munro, P
    Kaissl, W
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3249 - 3252
  • [8] To frame or not to frame? Cone-beam CT-based analysis of head immobilization devices specific to linac-based stereotactic radiosurgery and radiotherapy
    Babic, Steven
    Lee, Young
    Ruschin, Mark
    Lochray, Fiona
    Lightstone, Alex
    Atenafu, Eshetu
    Phan, Nic
    Mainprize, Todd
    Tsao, May
    Soliman, Hany
    Sahgal, Arjun
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 111 - 120
  • [9] CORRECTION STRATEGIES FOR CONE-BEAM CT GUIDED RADIOTHERAPY
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S141 - S142
  • [10] Clinical implementation of cone-beam CT guided radiotherapy
    van Herk, M
    Jaffray, D
    Remeijer, P
    Sonke, JJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S17 - S17