An open source automatic quality assurance (OSAQA) tool for the ACR MRI phantom

被引:0
|
作者
Jidi Sun
Michael Barnes
Jason Dowling
Fred Menk
Peter Stanwell
Peter B. Greer
机构
[1] University of Newcastle,
[2] Calvary Mater Newcastle,undefined
[3] CSIRO Australian E-Health Research Centre,undefined
关键词
Quality assurance; ACR MRI phantom; MR QA; Magnetic resonance imaging; Medical imaging;
D O I
暂无
中图分类号
学科分类号
摘要
Routine quality assurance (QA) is necessary and essential to ensure MR scanner performance. This includes geometric distortion, slice positioning and thickness accuracy, high contrast spatial resolution, intensity uniformity, ghosting artefact and low contrast object detectability. However, this manual process can be very time consuming. This paper describes the development and validation of an open source tool to automate the MR QA process, which aims to increase physicist efficiency, and improve the consistency of QA results by reducing human error. The OSAQA software was developed in Matlab and the source code is available for download from http://jidisun.wix.com/osaqa-project/. During program execution QA results are logged for immediate review and are also exported to a spreadsheet for long-term machine performance reporting. For the automatic contrast QA test, a user specific contrast evaluation was designed to improve accuracy for individuals on different display monitors. American College of Radiology QA images were acquired over a period of 2 months to compare manual QA and the results from the proposed OSAQA software. OSAQA was found to significantly reduce the QA time from approximately 45 to 2 min. Both the manual and OSAQA results were found to agree with regard to the recommended criteria and the differences were insignificant compared to the criteria. The intensity homogeneity filter is necessary to obtain an image with acceptable quality and at the same time keeps the high contrast spatial resolution within the recommended criterion. The OSAQA tool has been validated on scanners with different field strengths and manufacturers. A number of suggestions have been made to improve both the phantom design and QA protocol in the future.
引用
收藏
页码:39 / 46
页数:7
相关论文
共 50 条
  • [31] Quality assurance of open source components: Integrator point of view
    Maki-Asiala, Pekka
    Matinlassi, Mari
    30TH ANNUAL INTERNATIONAL COMPUTER SOFTWARE AND APPLICATIONS CONFERENCE, VOL 2, SHORT PAPERS/WORKSHOPS/FAST ABSTRACTS/DOCTORAL SYMPOSIUM, PROCEEDINGS, 2006, : 189 - +
  • [32] A novel anthropomorphic multimodality phantom for MRI-based radiotherapy quality assurance testing
    Singhrao, Kamal
    Fu, Jie
    Wu, Holden H.
    Hu, Peng
    Kishan, Amar U.
    Chin, Robert K.
    Lewis, John H.
    MEDICAL PHYSICS, 2020, 47 (04) : 1443 - 1451
  • [33] Preliminary study for a water-paraffin based phantom in MRI quality assurance test
    Lupi, Giulia
    Scorza, Andrea
    Rugiano, Maria Livia
    Sciuto, Salvatore Andrea
    Bini, Fabiano
    2015 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA) PROCEEDINGS, 2015, : 308 - 313
  • [34] An open-source tool for systemc to Verilog automatic translation
    Castillo, J.
    Huerta, P.
    Martinez, J. I.
    LATIN AMERICAN APPLIED RESEARCH, 2007, 37 (01) : 53 - 58
  • [35] An Open-Source Image Quality Assurance Software for Matlab/Octave
    Bedre, M.
    Alexandrian, A.
    Papanikolaou, N.
    Stathakis, S.
    Sampson, A.
    Rasmussen, K.
    Saenz, D.
    Kirby, N.
    MEDICAL PHYSICS, 2018, 45 (06) : E594 - E594
  • [36] A survey of quality assurance practices in biomedical open source software projects
    Koru, Guenes
    El Emam, Khaled
    Neisa, Angelica
    Umarji, Medha
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2007, 9 (02) : e8
  • [37] Open Source CT Scanner Quality Assurance Testing Report Generator
    Brenny, S.
    Ford, C.
    Reiter, R.
    Shumaker, H.
    Szczykutowicz, T.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [38] REGION SPECIFIC AUTOMATIC QUALITY ASSURANCE FOR MRI-DERIVED CORTICAL SEGMENTATIONS
    Gadewar, Shruti
    Zhu, Alyssa H.
    Thomopoulos, Sophia, I
    Li, Zhuocheng
    Gari, Iyad Ba
    Maiti, Piyush
    Thompson, Paul M.
    Jahanshad, Neda
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1288 - 1291
  • [39] Phantom-based quality assurance for multicenter quantitative MRI in locally advanced cervical cancer
    van Houdt, Petra J.
    Kallehauge, Jesper F.
    Tanderup, Kari
    Nout, Remi
    Zaletelj, Marko
    Tadic, Tony
    van Kesteren, Zdenko J.
    van den Berg, Cornelius A. T.
    Georg, Dietmar
    Cote, Jean-Charles
    Levesque, Ives R.
    Swamidas, Jamema
    Malinen, Eirik
    Telliskivi, Sven
    Brynolfsson, Patrik
    Mahmood, Faisal
    van der Heide, Uulke A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 114 - 121
  • [40] Simple, inexpensive, and ergonomic phantom for quality assurance control of MRI guided Focused Ultrasound systems
    Anastasia Antoniou
    Christakis Damianou
    Journal of Ultrasound, 2023, 26 : 401 - 408