Effect of repetitive square voltage frequency on partial discharge features

被引:0
|
作者
Peng Wang
GuangNing Wu
Yang Luo
GuangYa Zhu
机构
[1] Southwest Jiaotong University,School of Electrical Engineering
来源
关键词
inverter-fed motors; partial discharge; insulation system; qualification test; square voltages;
D O I
暂无
中图分类号
学科分类号
摘要
The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of considerations for PD measurements on inverter-fed motors were provided to improve the sensitivity of the PD test system and to obtain high objective insulation lifetime test results, which are used to assess the insulation status of inverter-fed motors.
引用
收藏
页码:1313 / 1321
页数:8
相关论文
共 50 条
  • [31] Influence of Temperature on Surface Discharge Characteristics of PEEK under Positive Repetitive Square Voltage
    Li, Ye
    Li, Xuebao
    Zhao, Zhibin
    Cui, Xiang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2021, 28 (05) : 1652 - 1660
  • [32] A Novel Approach to Partial Discharge Detection Under Repetitive Unipolar Impulsive Voltage
    Wang, Haihua
    Xiao, Guochun
    Wang, Laili
    Pei, Yunqing
    Yan, Feifei
    Yang, Qingshou
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (11) : 11681 - 11691
  • [33] Partial Discharge Analysis in a Needle-plane gap with Repetitive Step Voltage
    Wang, X.
    Niasar, M. Ghaffarian
    Clemence, R.
    Edin, H.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 92 - 95
  • [34] Simplified measurement method for partial discharge inception voltage under repetitive impulses
    Kadowaki, Kazunori
    Takemura, Yujiro
    Nishimoto, Sakae
    IEEJ Transactions on Fundamentals and Materials, 2012, 132 (09): : 811 - 812
  • [35] Partial Discharge Finite Element Analysis under Fast, Repetitive Voltage Pulses
    Borghei, Moein
    Ghassemi, Mona
    2019 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM (ESTS 2019): EMERGING TECHNOLOGIES FOR FUTURE ELECTRIC SHIPS, 2019, : 324 - 328
  • [36] Influence of Rise Time on Partial Discharge Extinction Voltage at Semi-square Voltage Waveforms
    Lindell, Elisabeth
    Bengtsson, Tord
    Blennow, Jorgen
    Gubanski, Stanislaw M.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) : 141 - 148
  • [37] High Temperature Partial Discharge Inception Voltage under Repetitive Impulse Voltage Applied to Motorette Samples
    Nishigaki, Yasutaka
    Matsuzoe, Takakazu
    Takenouchi, Sho
    Kozako, Masahiro
    Hikita, Masayuki
    Nakamura, Takahiro
    Sun, Jintong
    Izumi, Aoto
    Sakurai, Takayuki
    Karasawa, Kazunari
    Hiroshima, Satoshi
    2020 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2020, : 396 - 399
  • [38] Partial Discharge Spectral Response to Variations in the Supply Voltage Frequency
    Nyamupangedengu, Cuthbert
    Jandrell, Ian R.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (02) : 521 - 532
  • [39] Simulation of partial discharge within a void under square waveform applied voltage
    Illias, H. A.
    Bakar, A. H. A.
    Mokhlis, H.
    Tunio, M. A.
    Chen, G.
    Lewin, P. L.
    Ariffin, A. M.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 76 - 79
  • [40] Influence of Gas Type on Surface Discharge Characteristics of PEEK Under Positive Repetitive Square Voltage
    Qiu Z.
    Li X.
    Li Y.
    Zhao Z.