Effect of repetitive square voltage frequency on partial discharge features

被引:0
|
作者
Peng Wang
GuangNing Wu
Yang Luo
GuangYa Zhu
机构
[1] Southwest Jiaotong University,School of Electrical Engineering
来源
关键词
inverter-fed motors; partial discharge; insulation system; qualification test; square voltages;
D O I
暂无
中图分类号
学科分类号
摘要
The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of considerations for PD measurements on inverter-fed motors were provided to improve the sensitivity of the PD test system and to obtain high objective insulation lifetime test results, which are used to assess the insulation status of inverter-fed motors.
引用
收藏
页码:1313 / 1321
页数:8
相关论文
共 50 条
  • [21] Partial Discharge Features for Power Electronic Transformers Under High-Frequency Pulse Voltage
    Jiang, Jun
    Zhang, Bendong
    Li, Zhi
    Ranjan, Prem
    Chen, Jiawei
    Zhang, Chaohai
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2021, 49 (02) : 845 - 853
  • [22] Effect of temperature on partial discharge properties of polyimide film under continuous square impulse voltage
    Luo, Y. (luoyang_2004@126.com), 1600, Chinese Society for Electrical Engineering (32):
  • [23] Effect of Temperature on Partial Discharge and Breakdown Characteristics of Epoxy Resin Under Square Wave Voltage
    Shang X.
    Pang L.
    Bu Q.
    Zhang Q.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (08): : 3286 - 3295
  • [24] Phase Distribution Characteristics of Partial Discharge under Square Pulse Voltage
    Luo, Yang
    Wu, Guangning
    Zhou, Liren
    Guo, Xiaoxia
    Cao, Kaijiang
    ICPADM 2009: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2009, : 542 - 545
  • [25] Measurement and Analysis of Partial Discharge Current during Square Voltage Waveforms
    Sonerud, B.
    Bengtsson, T.
    Blennow, J.
    Gubanski, S. M.
    CEIDP: 2009 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2009, : 192 - 195
  • [26] Inception of Partial Discharges under Repetitive Square Voltages: Effect of Voltage Waveform and Repetition Rate on PDIV and RPDIV
    Cavallini, A.
    Lindell, E.
    Montanari, G. C.
    Tozzi, M.
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [27] Effect of energizing voltage frequency on partial discharge characteristics of defects in power cable joints
    Wang, Li
    Jin, Lei
    Li, Hongjie
    ENERGY REPORTS, 2023, 9 : 518 - 524
  • [28] Cable Commissioning and Diagnostic Tests: The Effect of Voltage Supply Frequency on Partial Discharge Behavior
    Peng, Xianyong
    Xiong, Qing
    Gattozzi, Angelo
    Montanari, Gian Carlo
    Seri, Paolo
    Hebner, Robert
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 373 - 376
  • [29] Effect of energizing voltage frequency on partial discharge characteristics of defects in power cable joints
    Wang, Li
    Jin, Lei
    Li, Hongjie
    ENERGY REPORTS, 2023, 9 : 518 - 524
  • [30] Effect of energizing voltage frequency on partial discharge characteristics of defects in power cable joints
    Wang, Li
    Jin, Lei
    Li, Hongjie
    ENERGY REPORTS, 2023, 9 : 518 - 524