Radiation Dose Reduction in Pediatric Cardiac Computed Tomography: Experience from a Tertiary Medical Center

被引:0
|
作者
Brian B. Ghoshhajra
Ashley M. Lee
Leif-Christopher Engel
Csilla Celeng
Mannudeep K. Kalra
Thomas J. Brady
Udo Hoffmann
Sjirk J. Westra
Suhny Abbara
机构
[1] Massachusetts General Hospital,Cardiac MR PET CT Program, Department of Radiology
来源
Pediatric Cardiology | 2014年 / 35卷
关键词
Cardiac computed tomography angiography; Pediatrics; Children; Low dose; Radiation;
D O I
暂无
中图分类号
学科分类号
摘要
Cardiac CT angiography (cCTA) has become an established method for the assessment of congenital heart disease. However, the potential harmful effects of ionizing radiation must be considered, particularly in younger, more radiosensitive patients. In this study, we sought to assess the temporal change in radiation doses from pediatric cCTA during an 8-year period at a tertiary medical center. This retrospective study included all patients ≤18 years old who were referred to electrocardiography (ECG)-gated cCTA for the assessment of congenital heart disease or inflammatory disease (Kawasaki disease) from November 2004 to September 2012. During the study period, 95 patients were scanned using 3 different scanner models—64-slice multidetector CT (64-MDCT) and first- (64-DSCT) and second-generation (128-DSCT) dual-source CT—and 3 scan protocols—retrospective ECG-gated helical scanning (RG), prospective ECG-triggered axial scanning (PT), or prospective ECG-triggered high-pitch helical scanning (HPH). Effective dose (ED) was calculated with the dose length product method with a conversion factor (k) adjusted for age. ED was then compared among scan protocols. Image quality was extracted from clinical cCTA reports when available. Overall, 94 % of scans were diagnostic (80 % for 64-slice MDCT, 93 % for 64-slice DSCT, and 97 % for 128-slice DSCT).With 128-DSCT, median ED (1.0 [range 0.6–2.0] mSv) decreased by 85.8 % and 66.8 % compared with 64-MDCT (6.8 [range 2.9–13.6] mSv) and 64-DSCT (2.9 [range 0.9–4.1] mSv), respectively. With HPH, median ED (0.9 [range 0.6–1.8] mSv) decreased by 59.4 % and 85.4 % compared with PT (2.2 [range 0.9–3.4] mSv) and RG (6.1 [range 2.5–10.6] mSv). cCTA can now be obtained at very low radiation doses in pediatric patients using the latest dual-source CT technology in combination with prospective ECG-triggered HPH acquisition.
引用
收藏
页码:171 / 179
页数:8
相关论文
共 50 条
  • [21] Pediatric computed tomography.: Radiation dose in abdominal studies
    Lopez, X.
    Ruiz-Trejo, C.
    Buenfil, A. E.
    Gamboa-deBuen, I.
    Dies, P.
    MEDICAL PHYSICS, 2008, 1032 : 186 - +
  • [22] Dose Reduction in Pediatric Computed Tomography with Automated Exposure Control
    Alibek, Sedat
    Brand, Martin
    Suess, Christoph
    Wuest, Wolfgang
    Uder, Michael
    Greess, Holger
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 690 - 693
  • [23] Multidetector computed tomography (MDCT) and dose reduction in pediatric radiology
    Heyer, C. M.
    MONATSSCHRIFT KINDERHEILKUNDE, 2011, 159 (04) : 343 - 349
  • [24] Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently ‘Have-A-Heart’ campaign
    Cynthia K. Rigsby
    Sarah E. McKenney
    Kevin D. Hill
    Anjali Chelliah
    Andrew J. Einstein
    B. Kelly Han
    Joshua D. Robinson
    Christina L. Sammet
    Timothy C. Slesnick
    Donald P. Frush
    Pediatric Radiology, 2018, 48 : 5 - 20
  • [25] Radiation dose management for pediatric cardiac computed tomography: a report from the Image Gently 'Have-A-Heart' campaign
    Rigsby, Cynthia K.
    McKenney, Sarah E.
    Hill, Kevin D.
    Chelliah, Anjali
    Einstein, Andrew J.
    Han, B. Kelly
    Robinson, Joshua D.
    Sammet, Christina L.
    Slesnick, Timothy C.
    Frush, Donald P.
    PEDIATRIC RADIOLOGY, 2018, 48 (01) : 5 - 20
  • [26] A Reduction in Radiation Exposure During Pediatric Craniofacial Computed Tomography
    Zarella, Christopher
    Didier, Ryne
    Bergquist, Curtis
    Bardo, Dianna M. E.
    Selden, Nathan R.
    Kuang, Anna A.
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (02) : 331 - 333
  • [27] Radiation dose in multidetector row computed tomography cardiac imaging
    Bae, KT
    Hong, C
    Whiting, BR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (06) : 859 - 863
  • [28] Practical Strategies for Low Radiation Dose Cardiac Computed Tomography
    Henzler, Thomas
    Hanley, Michael
    Arnoldi, Elisabeth
    Bastarrika, Gorka
    Schoepf, U. Joseph
    Becker, Hans-Christoph
    JOURNAL OF THORACIC IMAGING, 2010, 25 (03) : 213 - 220
  • [29] Established and emerging dose reduction methods in cardiac computed tomography
    Gary R. Small
    Mustapha Kazmi
    Robert A. deKemp
    Benjamin J. W. Chow
    Journal of Nuclear Cardiology, 2011, 18
  • [30] Established and emerging dose reduction methods in cardiac computed tomography
    Small, Gary R.
    Kazmi, Mustapha
    deKemp, Robert A.
    Chow, Benjamin J. W.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (04) : 570 - 579