A Reduction in Radiation Exposure During Pediatric Craniofacial Computed Tomography

被引:4
|
作者
Zarella, Christopher [1 ]
Didier, Ryne [3 ]
Bergquist, Curtis [2 ]
Bardo, Dianna M. E. [3 ]
Selden, Nathan R. [4 ]
Kuang, Anna A. [2 ]
机构
[1] Oregon Hlth & Sci Univ, Div Plast & Reconstruct Surg, Portland, OR 97239 USA
[2] Oregon Hlth & Sci Univ, Div Pediat Surg, Dept Surg, Mail Code CDW 229,3181 SW Sam Jackson Pk Rd, Portland, OR 97239 USA
[3] Oregon Hlth & Sci Univ, Dept Radiol, Portland, OR 97239 USA
[4] Oregon Hlth & Sci Univ, Dept Neurol Surg, Portland, OR 97239 USA
关键词
Craniofacial CT; head position; pediatric; radiation dose; CT; SCANS; RISK; HEAD; SURGERY;
D O I
10.1097/SCS.0000000000002374
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background:Radiation exposure during computed tomography (CT) evaluation in children is the subject of growing professional and public concern. The authors previously demonstrated an 18% reduction in effective radiation dose during craniofacial CT imaging using a modified head position (exaggerated sniff), without any compromise of image diagnostic quality. The current study reports additional reduction of radiation exposure using a commercially available iterative reconstruction CT technique.Methods:This single-institution, retrospective cohort study compared the overall effective radiation dose received during elective pediatric craniofacial CT imaging. Patients imaged using the iterative reconstruction and exaggerated sniff protocol combined (January 2010 through December 2013) were compared with those undergoing imaging with the exaggerated sniff position alone, between October 2008 and January 2010.Results:A total of 325 patients who underwent CT imaging with the exaggerated sniff position, decreased dose and iterative reconstruction protocol experienced an average effective radiation dose of 1.22mSv (47% reduction), compared with 2.32mSv for the sniff-position alone group. Age-matched reference patients not treated using either protocol received an average of 2.82mSv. This represents a 56.7% average radiation dose reduction for combined sniff position and iterative reconstruction patients compared with reference patients and 47.4% reduction compared with the sniff-position alone group. Image quality of both bone and brain windows was equivalent.Conclusions:Altering head position and use of iterative reconstruction technique with a reduced radiation protocol diminishes CT imaging-related effective radiation dose by approximately 50% in children undergoing elective cranial CT imaging for craniofacial disorders.
引用
收藏
页码:331 / 333
页数:3
相关论文
共 50 条
  • [1] Craniofacial Flash: Minimizing Radiation Dose in Pediatric Craniofacial Computed Tomography
    Stewart, Neil M.
    Hallac, Rami R.
    Chou, Pang-Yun
    Koral, Korgun
    Blackburn, Tim
    Kane, Alex A.
    Seaward, James R.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (07) : 1751 - 1754
  • [2] Radiation exposure estimation in pediatric patients during computed tomography imaging procedures
    Sulieman, Abdelmoneim
    Almogren, Kholoud S.
    Tamam, Nissren
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [3] COMPUTED TOMOGRAPHY OF PEDIATRIC CRANIOFACIAL SARCOMA
    ZIMMERMAN, RA
    BILANIUK, LT
    LITTMAN, P
    RANEY, RB
    [J]. CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1978, 2 (02): : 113 - 121
  • [4] Dose Reduction in Pediatric Computed Tomography with Automated Exposure Control
    Alibek, Sedat
    Brand, Martin
    Suess, Christoph
    Wuest, Wolfgang
    Uder, Michael
    Greess, Holger
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (06) : 690 - 693
  • [5] Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging
    Albert, Gregory W.
    Glasier, Charles M.
    [J]. NEUROSURGERY, 2015, 77 (02) : 228 - 232
  • [6] Radiation Exposure in Computed Tomography
    Bos, Denise
    Guberina, Nika
    Zensen, Sebastian
    Opitz, Marcel
    Forsting, Michael
    Wetter, Axel
    [J]. DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (09): : 135 - +
  • [7] Radiation exposure in computed tomography
    Gosch, D
    Kloeppel, R
    Lieberenz, S
    Schulz, HG
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 167 - 169
  • [8] Radiation exposure from head computed tomography scans in pediatric trauma
    Sharp, Nicole E.
    Svetanoff, Wendy J.
    Desai, Amita
    Alemayehu, Hanna
    Raghavan, Maneesha U.
    Sharp, Susan W.
    Brown, James C.
    Rivard, Douglas C.
    St Peter, Shawn D.
    Holcomb, George W., III
    [J]. JOURNAL OF SURGICAL RESEARCH, 2014, 192 (02) : 276 - 279
  • [9] Management of auto exposure control during pediatric computed tomography
    Cody, Dianna D.
    [J]. PEDIATRIC RADIOLOGY, 2014, 44 : 427 - 430
  • [10] Management of auto exposure control during pediatric computed tomography
    Dianna D. Cody
    [J]. Pediatric Radiology, 2014, 44 : 427 - 430