Measurements of the semiconductor substrate thickness with a low-coherence tandem interferometer at a nonstationary temperature

被引:0
|
作者
P. V. Volkov
A. V. Goryunov
A. Yu. Luk’yanov
A. D. Tertyshnik
机构
[1] Russian Academy of Sciences,Institute for Physics of Microstructures
来源
Technical Physics Letters | 2015年 / 41卷
关键词
Technical Physic Letter; Optical Thickness; Substrate Thickness; Phase Thickness; Nonstationary Temperature;
D O I
暂无
中图分类号
学科分类号
摘要
We propose an original technique for measuring minor variations in the semiconductor structure thickness at nonstationary temperature with the use of the principle of low-coherence tandem interferometry. The attained temperature and thickness resolutions are ±2°C and ±2 nm, respectively.
引用
收藏
页码:110 / 112
页数:2
相关论文
共 50 条
  • [21] Absolute thickness metrology with submicrometer accuracy using a low-coherence distance measuring interferometer
    Zhao, Yang
    Schmidt, Greg
    Moore, Duncan T.
    Ellis, Jonathan D.
    [J]. APPLIED OPTICS, 2015, 54 (25) : 7693 - 7700
  • [22] Real-time measurement of substrate temperature in molecular beam epitaxy using low-coherence tandem interferometry
    Yurasov, D. V.
    Luk'yanov, A. Yu.
    Volkov, P. V.
    Goryunov, A. V.
    Tertyshnik, A. D.
    Drozdov, M. N.
    Novikov, A. V.
    [J]. JOURNAL OF CRYSTAL GROWTH, 2015, 413 : 42 - 45
  • [23] Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples
    Kim, Do-Hyun
    Song, Chul-Gyu
    Ilev, Ilko K.
    Kang, Jin U.
    [J]. APPLIED OPTICS, 2011, 50 (06) : 970 - 974
  • [24] The use of low-coherence interferometer for sugar content determination
    Jedrzejewska-Szczerska, M.
    [J]. SARATOV FALL MEETING 2014: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XVI; LASER PHYSICS AND PHOTONICS XVI; AND COMPUTATIONAL BIOPHYSICS, 2015, 9448
  • [25] COMPACT IN-LINE INTERFEROMETER FOR LOW-COHERENCE REFLECTOMETRY
    SCHMITT, JM
    [J]. OPTICS LETTERS, 1995, 20 (04) : 419 - 421
  • [26] Semiconductor line source for low-coherence interferometry
    Zvyagin, AV
    Garcia-Webb, MG
    Sampson, DD
    [J]. APPLIED OPTICS, 2001, 40 (06) : 913 - 915
  • [27] Low-coherence interferometer using a pulsation laser diode
    Suzuki, Takamasa
    Ueno, Yusuke
    Choi, Samuel
    Sasaki, Osami
    [J]. DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS III, 2014, 9110
  • [28] MEASUREMENT OF CORNEAL THICKNESS BY LOW-COHERENCE INTERFEROMETRY
    HITZENBERGER, CK
    [J]. APPLIED OPTICS, 1992, 31 (31): : 6637 - 6642
  • [29] Low-coherence interferometer for contact lens surface metrology
    Heideman, Kyle C.
    Greivenkamp, John E.
    [J]. OPTICAL ENGINEERING, 2016, 55 (03)
  • [30] Simultaneous film thickness measurement and wall temperature assessment by Low-Coherence Interferometry
    Borgetto, Nicolas
    Andre, Frederic
    Galizzi, Cedric
    Escudie, Dany
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 : 512 - 519